SMC Corporation of America
Elite Part Number Search
Search Results "11-CJ2B6-45R"

B H B H d C C d 10 8 21 M4 X 0.7 16.2 Y-J010B SNJ-006B 16 11 21 M5 X 0.8 16.6 Y-J016B M6 X 1.0 4 8 9.2 6 NTJ-006A 2.4 M3 X 0.5 6.4 5.5 6 SNJ-010B M8 X 1.0 4 11 12.7 10 NTJ-010A 3.2 M4 X 0.7 8.1 7 10 Part No.

(Example) CDJ5B10SV-45R B H7BAL Without auto switch D-H7BAL (Water resistant) Only band mounting auto switches are available. Only perpendicular to the axis for double clevis style. Applicable Auto Switch/Refer to page 1306 for further information on auto switches.

Magnet: None, Mounting: Basic Style, Bore Size: 6mm, Stroke: 45mm, Cushion: Rubber Bumper, Head Cover Port: Axial, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Clean Series: 10 (Relief Type), Magnet: None, Series: J2, Mounting: B (Basic Style), Bore Size: 6mm, Stroke: 45mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: R (Axial Direction)

Clean Series: Relief Type, Magnet: None, Series: J2, Mounting: Basic Style, Bore Size: 6mm, Stroke: 45mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Axial Direction, Version: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Type: -

Magnet: None, Mounting: Basic Style, Bore Size: 6mm, Stroke: 45mm, Cushion: Rubber Bumper, Head Cover Port: Axial, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Low Speed, 10 to 50mm/s

This is a legacy product, and replaced by10-CJ2B6-10RZ, CYL, RND BODY, CLEAN ROOM, ACTUATOR, CJ2 ROUND BODY CYLINDER, C5, 6MM CJ2 CLEAN-ROOM, .22046 lb

Please contact us for the latest version.sales@ocaire.com, CJ2B6-15SR SIMPLE SPECIAL XA11, ROUND BODY CYLINDER

Clean Series: 11 (Vacuum Suction Type), Magnet: None, Series: J2, Mounting: B (Basic Style), Bore Size: 6mm, Stroke: 100mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: R (Axial Direction)

Clean Series: 11 (Vacuum Suction Type), Magnet: None, Series: J2, Mounting: B (Basic Style), Bore Size: 6mm, Stroke: 30mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: R (Axial Direction)

Clean Series: 11 (Vacuum Suction Type), Magnet: None, Series: J2, Mounting: B (Basic Style), Bore Size: 6mm, Stroke: 15mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: R (Axial Direction), Version: Z

Clean Series: 11 (Vacuum Suction Type), Magnet: None, Series: J2, Mounting: B (Basic Style), Bore Size: 6mm, Stroke: 15mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: R (Axial Direction)

Clean Series: Vacuum Suction Type, Magnet: None, Series: J2, Mounting: Basic Style, Bore Size: 6mm, Stroke: 100mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Axial Direction, Version: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Type: -

Clean Series: Vacuum Suction Type, Magnet: None, Series: J2, Mounting: Basic Style, Bore Size: 6mm, Stroke: 30mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Axial Direction, Version: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Type: -

Clean Series: Vacuum Suction Type, Magnet: None, Series: J2, Mounting: Basic Style, Bore Size: 6mm, Stroke: 15mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Axial Direction, Version: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Type: -

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.14 to 0.7, Specification: Without magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.14 to 0.7, Specification: Without magnet, Auto Switches: Without

Clean Series: 11 (Vacuum Suction Type), Magnet: None, Series: J2, Mounting: B (Basic Style), Bore Size: 10mm, Stroke: 45mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: R (Axial Direction)

Clean Series: Vacuum Suction Type, Magnet: None, Series: J2, Mounting: Basic Style, Bore Size: 10mm, Stroke: 45mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Axial Direction, Version: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Type: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, DBL ACT, ACTUATOR, CJ2 ROUND BODY CYLINDER, CD, 6MM CJ2 DOUBLE-ACTING, .07822 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CJ2Air cylinderCJ2Double acting, Single rodExcept with air cushion666