SMC Corporation of America
Elite Part Number Search
Search Results "10-MGF100-50-M9BW"

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port

Bore Size: 100mm, Port Type: Rc, Stroke: 50mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port

Bore Size: 100mm, Port Type: Rc, Stroke: 50mm, Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 100mm, Port Type: Rc, Stroke: 50mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port

Please contact us for the latest version.sales@ocaire.com, BUSHING, MGF100, ACTUATOR, MGF COMPACT GUIDE CYLINDER, S1, 100MM MGF PART, .00000 lb

35 + 25 (n 2) (n = 2, 3, 4, 5) CJ2 D-A9lV 5 10 35 10 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 25 (n 2) (n = 2, 3, 4, 5) CM2 Band mounting CG1 D-H7l/H7lW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) MB D-C7l D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) CA2 D-H7C D-C73C D-C80C 10 15 65 15 + 50(n 2)

, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50,7 5, 100, 125, 150 *90and 91-series MXQ6 products do not have shock absorbers.

(n 2) (n = 2, 4, 6) (n=2, 4, 6) (n 2) 2 15 + 50 D-H7C D-C73C D-C80C 10 15 65 65 + 50 (n 2) (n = 2, 4, 6) D-H7C D-C73C D-C80C 10 15 65 50 + 27.5 (n 2) (n = 2, 4, 6) (n 2) 2 15 + 50 (n = 2, 4, 6) (n = 2, 4, 6) D-F7lV D-J79C 5 5 10 + 10 (n 2) (n = 4, 6) D-F7l D-J79 5 5 15 + 15 (n 2) (n = 4, 6) D-A9l D-A9lV 5 10 10 + 15 (n 2) (n = 4, 6) D-A7l D-A80 D-A73C D-A80C D-M9lV D-F7lV D-J79C

Bore Size: 100mm, Port Thread: Rc, Stroke: 30mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal

Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal

Bore Size: 100mm, Port Thread: Rc, Stroke: 30mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

+ 35(n 2) 2 (n = 2, 4, 6)3 35 + 25 (n 2) (n = 2, 3, 4, 5) CM2 Band mounting D-H7/H7W D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6)3 60 + 22.5 (n 2) (n = 2, 3, 4, 5) CM3 CG1 D-C7 D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6)3 50 + 20 (n 2) (n = 2, 3, 4, 5) CG3 D-H7C D-C73C D-C80C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6)3 50 + 27.5 (n 2) (n = 2, 3, 4, 5) JMB D-M9V 5 5 10 + 10 (n

M8 x 1.25 28.5 7 41 9 25 6 17 75,100 40.5 88.5 B + Stroke MH + Stroke A + 2 x (Stroke) 5 to 50 40 (50) 88 (98) 40 M10 x 1.25 27 46 7 41 10 25 6 19 32 to 100 75,100 50 98 10 to 50 100.5 (110.5) 40.5 (50.5) MI MM 50 M14 x 1.5 31 57 8 52 13 35 8 24 75,100 110.5 50.5 10 to 50 102 (112) 42 (52) 63 M14 x 1.5 31 68 8 52 13 35 10 24 G 75,100 112 52 10 to 50 125 (135) 51 (61) 80 MA ML MK M20 x 1.5

CHKm Standard Strokes JIS symbol CHN CHM Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 CHSm 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 CH2m 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 CHA 10, 15, 20, 25, 30, 35, 40,