Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.035~1.0, Cushion: None, Specification
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.035~1.0, Cushion: None, Specification
st 10 st 10 st 10 st 5 st 5 st 5st 5 st 5 st M4 x 0.7 6 6 9 10 12 5 60.5 27 54.5 13.5 24 50.5 22 44.5 8.5 19 4 7 14 5 10 M4 x 0.7 14 5 53 63 23.5 28.5 47 57 8.5 13.5 20.5 25.5 4 10 15 6.5 12 M6 x 1.0 20 8 61 71 24.5 29.5 52 62 9.5 14.5 23.5 28.5 5 12 18 8 16 M6 x 1.0 24 10 67.5 77.5 27.5 32.5 57.5 67.5 10 15 27.5 32.5 5 14 20 10 20 Double clevis bracket material: Carbon steel For details
67.5 72.5 37.5 62.5 10 5 14 20 10 20 5 22.5 M6 X 1.0 10 Refer to p.2.3-18 for rod end nut and option bracket.
5st 5 st 5 st 10 st 10 st 10 st 10 st 10 st M4 x 0.7 6 6 9 10 12 5 50.5 22 44.5 4 7 14 5 10 8.5 19 60.5 27 54.5 13.5 24 M4 x 0.7 14 5 53 23.5 47 4 10 15 6.5 12 8.5 20.5 63 28.5 57 13.5 25.5 M6 x 1.0 20 8 61 24.5 52 5 12 18 8 16 9.5 23.5 71 29.5 62 14.5 28.5 M6 x 1.0 24 10 67.5 27.5 57.5 5 14 20 10 20 10 27.5 77.5 32.5 67.5 15 32.5 Double clevis bracket material: Carbon steel For details
Magnet: D (Built-in), Mounting: B [Through Hole, Both Ends Tapped (Standard)], Bore Size: 25mm, Stroke: 25mm, Option: M (Rod End Male Thread)
Magnet: Built-in, Mounting: B [Through Hole, Both Ends Tapped (Standard)], Bore Size: 25mm, Stroke: 25mm, Option: Rod End Male Thread, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Please contact us for the latest version.sales@ocaire.com, CDQ2B50-25DM-A73HL *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, NE, 50MM CQ2 DBL-ACT AUTO-SW, .00000 lb
Specification: 11 (Vacuum Suction Type), Magnet: D (w/Auto Switch, Built-in Magnet), Bore: 25mm, Stroke: 25mm, Rod End: M (Rod End Male Thread)
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Cushion: None, Specification
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Cushion: None, Specification
Specification: 11 (Vacuum Suction Type), Magnet: D (w/Auto Switch, Built-in Magnet), Bore: 25mm, Stroke: 25mm, Rod End: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Specification: Vacuum Suction Type, Magnet: w/Auto Switch, Built-in Magnet, Bore: 25mm, Stroke: 25mm, Rod End: Rod End Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Cushion: None, Specification
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Cushion: With rubber
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Cushion: None, Specification
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Low Speed / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Cushion: With rubber