. *4 The facility water flow rate that satisfies the rated conditions with a facility water inlet temperature of 32C and an output temperature of 37C ( t = 5C) *5 These values are obtained under rated conditions with a rated facility water flow rate and a facility water inlet pressure of 0.2 MPa. *6 These values are obtained under rated conditions (1 RT = 4.535 kW). *7 These values are reference

Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

Take measures to prevent freezing when below 5C, since moisture in circuits can be frozen, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Caution 1.

In addition, the cooling water cannot theoretically be cooled to a temperature any lower than 5C above the wet-bulb temperature of the outside air.

Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Maintenance Warning 1. Removal of equipment, and supply/exhaust of compressed air.

Take measures to prevent freezing when below 5C, since moisture in circuits can freeze and cause damage to seals and lead to malfunctions. Refer to SMCs Air Preparation System catalog for further details on compressed air quality. 1. Do not scratch or gouge the cylinder tube or the sliding parts of the piston rod by striking or grasping them with other objects.

Use in low temperature environments The valve can be used at a temperature down to 5C. Take appropriate measures to avoid freezing of drainage, moisture, etc. 2. Operation method The valve must be switched to each position instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction.

If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to Best Pneumatics No. 5. CRA1 CRQ2 MSQ MSZ CRQ2X MSQX MRQ Lubrication Operating Environment Warning Warning 1. This product should be used without lubrication.

Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance

If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to Best Pneumatics No. 5. Lubrication Caution 1. The non-lube type air gripper is lubricated at the factory, and can be used without any further lubrication.

Take measures to prevent freezing when 5C or less, since moisture in circuits can freeze and cause damage to seals and lead to malfunctions. Piping Caution 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil, and other debris from inside the pipe. 2.

Take measures to prevent freezing when 41F (5C) or less, since moisture in circuits can freeze and cause damage to seals and lead to malfunctions. Piping Caution 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil, and other debris from inside the pipe. 2.

Take measures to prevent freezing at temperature below 5C, since moisture in circuits may freeze and cause damage to seals and lead to malfunctions. 5. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. Cushion Caution 1.

Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Maintenance Warning 1. Removal of equipment, and supply/exhaust of compressed air.

53 3234 1 10 mm or 3/8" 36.0 50.0 322 106 6468 1 10 mm or 3/8" 70.0 100.0 QP Stroke volume dm3 / in3 NPT Piping Air (s) Spring (s) Piping Air (s) Spring (s) Piping Air (s) Spring (s) 1C 0.62 37 3/8 10 mm or 3/8" [6 mm or 1/4" (x)] * * 10 mm or 3/8" [6 mm or 1/4" (x)] 1.2* 2.1* 2C 1.08 66 3/8 10 mm or 3/8" 2.4 3.0 3C 2.18 133 3/8 10 mm or 3/8" 4.8 5.2 4C 4.34 265 3/8 10 mm or 3/8" 3.2 3.7 5C

Piping Caution Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. 1. Preparation before piping.

Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality.

Take measures to prevent freezing when below 5C, since moisture in circuits can freeze and cause damage to seals and lead to malfunctions. For details on the quality of compressed air mentioned above, refer to SMCs Best Pneumatics catalog vol. 14. 5. Do not use until you verify that the equipment can operate properly.

Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Piping Operating Environment Caution Warning 1.

(However, auto switch mounting brackets are assembled when being shipped.) 396 Series CA2WH Air-hydro Cylinder: Air-hydro Type Double Acting, Double Rod Specifications Bore size (mm) 100 80 63 50 40 Type Air-hydro Fluid Turbine oil Action Double acting Proof pressure 1.5 MPa CJ1 Maximum operating pressure 1.0 MPa Minimum operating pressure 0.16 Mpa CJP Piston speed 0.5 to 300 mm/s 5C to 60C