Model: 10S6 (Side Ported), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: 5 (Negative Common, 7/8" Connector), I/O Unit Stations: None, Valve Stations: 2 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C4 (ø4 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: FA (PROFINET - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 02 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10S (Side Ported), SI Unit Specification: 0 (w/o SI Unit), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Model: 10S (Side Ported), SI Unit Specification: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C10 (ø10 One-touch Fitting, Straight, Metric), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail
Model: 10S3 (Side Ported), SI Unit: ZB (CompoNetâ„¢, Positive Common, NPN), Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: C12 (ø12 One-touch Fitting, Straight, Metric), Mounting: D (DIN Rail Mounting w/o Name Plate)
Body Size: 20, Back Flow: w/o Backflow, Thread: Rc, Port Size: 02 (1/4), Mounting Option: B (With Bracket), Float Type Auto Drain Option: Without Auto Drain, Pressure Gauge/Switch Option: Without Pressure Gauge, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: C (w/Bowl Guard), Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: R (Flow
Body Size: 30, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 02 (1/4), Option: B (Bracket), Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Standard
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8
Exhaust cleaner, series AMP, can be used inside a clean room. Depending on operating conditions, exhaust air cleanliness may be equivalent to Class 100. Since exhaust air from pneumatic equipment can be released directly into a clean room, piping to ducts is unnecessary thereby reducing piping labor costs and increasing space savings. Exhaust air cleanliness: equivalent to class 100 , Worry
The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is made of ozone resistant rubber material (HNBR) , Improved relief sensitivity , 6 Sizes , Rc, NPT or G(PF) threads, REGULATOR, MODULAR, 1/4 R, AIRLINE EQUIPMENT, AR MASS PRO, DA, AR MASS PRO
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AF MASS PRO 1/4 MODULAR (PT), AIRLINE EQUIPMENT, AF MASS PRO, DA, AF MASS PRO 1/4 MODULAR (PT), 1.35824 lb
Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
The VHS series provides a convenient means of isolating supplied pressure in a pneumatic system and exhausting downstream pressure for maintenance purposes. The units can be locked in the exhaust position and can be an integral part of an energy isolation system. Air flow direction is easily identified by handle orientation and labeling. The epoxy coated version provides an economical alternative
The VHS series provides a convenient means of isolating supplied pressure in a pneumatic system and exhausting downstream pressure for maintenance purposes. The units can be locked in the exhaust position and can be an integral part of an energy isolation system. Air flow direction is easily identified by handle orientation and labeling. The epoxy coated version provides an economical alternative
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HAND VALVE, VALVE, VHS HAND VALVE, F6, VHS BODY PT 1/4, .50391 lb
Special Application: 10-AW (Clean Series), Body Size: 20, Reverse Flow: K (Reverse Flow Mechanism), Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: 2 (Metal Bowl), Option 2: JNR (JN + Right to Left Flow Direction)
Special Application: 10-AW (Clean Series), Body Size: 30, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: None, Option 2: J (Drain Guide)
Special Application: 10-AW (Clean Series), Body Size: 30, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: None, Option 2: JN (Drain Guide + Non-relieving Type)
Special Applications: 10-AR (Clean Series), Body Size: 25, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: 1N (1+N)
Special Applications: 10-AR (Clean Series), Body Size: 25, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: N (Non-relieving)