EtherNet type Item Specifications Fieldbus EtherNet (IE802.3) Media 100BASE-TX Communication speed 10/100Mbps (Automatically selected) Maximum length of cable 100m (328) Fieldbus protocol EtherNet/IP TM Occupied area (inputs /outputs) 2048 point256byte/2048 point256byte IP address setting DHCP server.
As an example, for a travel of 100m; Travel distance of the actuator per 1 pulse = 0.01 (mm) *1 100 (mm)/0.01 (mm) = 10 (pulse) *1 The travel distance of the actuator per 1 pulse is set according to the electronic gears (PA05/PA06/PA07) outlined in 5.3.4 Recommended Parameter Values by Actuator Model. If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.
200byte Communication speed 125k/250k/500kbps Configuration file EDS Device Infomation Vender code: 7 (SMC Corp) Product code: 143 Corresponding message Poll, Strobe, Change of stats, Cyclic DeviceNetTM of power DC1124V Terminating resistor None Communication speed(bps) Maximum length of cable 125k 250k 500k fat cable 500 less 250 less 100 less Maximum length of network cable(m) thin cable 100m
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 2) Although wire length does not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch.
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 2) Although wire length should not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch.
(mm) +0.2 0.1 +0.2 0.1 0.1 0.1 Tolerance Basic diameter 1.0 1.6 0.5 1.5 0.5 0.8 1.2 Thickness (mm) 0.1 0.15 0.05 0.15 0.05 0.08 0.12 Tolerance 10m 20m Bundle 50m 100m Straight pipe 2m Translucent (color of material) Color Please refer to the applicable fluid in Feature 6.
Voltage resistance Between external terminal and housing 100M (50V DC by megameter) Insulation resistance 10 to 55Hz Pulse width: 1.5mm to X, Y, Z direction (2 hours) Vibration resistance 294 m/s2 (11ms or less) to X, Y, Z direction (3 times for each direction) Shock resistance IP65 Protective construction Housing Housing: Stainless steel (SUS304), Fitting: Stainless steel (SUS304) Material
As an example, for a travel of 100m; Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) *1 The travel distance of the actuator per 1 pulse is set according to the electronic gears (PA06/PA07) outlined in 5.3.4 Recommended Parameter Values by Actuator Model. If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.
As an example, for a travel of 100m; Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) *1 The travel distance of the actuator per 1 pulse is set according to the electronic gears (PA06/PA07) outlined in 5.3.4 Recommended Parameter Values by Actuator Model. If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.