SMC Corporation of America
Elite Part Number Search
Search Results "52-IP8001-034-F-3"

AMC CA A 3 Body size Thread/Applicable to drain piping 2 AMC220 AMC310, 320 AMC510, 520 AMC610 AMC810 AMC910 Rc(PT) 3 5 6 8 9 N NPT Exhaust of oil mist F G(PF) A Drain cock (Standard) D Drain piping Note 1) On the type for the AMC220, an R(PT) fitting can be attached by removing the drain cock (It becomes the drain piping style).

ANR: 20C atmospheric pressure, relative humidity 65% 200 300 , 0.2 AMC-EL3 BE30 1,000 1 4 3 8 1 4 , 3 4 1 2 0.12 AMC-EL2 BE20 0.5 AMC-EL5 BE50 5-10-11

AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12

voltage drop 2.4 V or less (to 20 mA) / 3 V or less (40 mA) F: D-sub connector (9P) Indicator light Red light emitting diode (LED) lights up when ON.

Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.

Note 2) AS900 is available as special. 1/4 3/8 1/2 3/4 1 1 1 2 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 543 to 546 for Flow Control Equipment Precautions. AS420 Thread type AS500 AS600 AS800 Nil Rc NPT G N F 1 4 1 2 AS900 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.

After displaying for 3 seconds, it will return to the measuring mode. Due to the individual product difference, the setting range varies 10% F.S. Blue DC() -26 Analog output type 1 to 5V (2.5% F .S.) Output impedance: 1k Bring the pressure back to atmospheric pressure and try using the zero out function.

or more) Window comparator mode: Fixed (Min. pressure indication value x 3) Hysteresis mode: Variable (Min. pressure indication value x 3 or more) Window comparator mode: Fixed (Min. pressure indication value x 3) Hysteresis Over pressure, Over current, Data error Over pressure, Data error Self diagnosis function Operating voltage Current consumption Error indication Operating temperature

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, AS***F 1/8INCSTANDARD (NPT), AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, CD, AS***F 1/8INCSTANDARD (NPT), 0.03853 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, AS***F 1/8INCSTANDARD (NPT), AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, CD, AS***F 1/8INCSTANDARD (NPT), ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, AS***F 1/8INCSTANDARD (NPT), AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, CD, AS***F 1/8INCSTANDARD (NPT), ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, AS***F 1/8INCSTANDARD (NPT), AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, CD, AS***F 1/8INCSTANDARD (NPT), ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R

A bracket is included with the product. 13-10-8 3 Series ZFC Air Suction Filter In-line Type with One-touch Fittings Dimensions Applicable tubing O.D.

Operating Pressure Particulate Generation Grade Classifications 1.2 104 Average particle concentration Particles/ft3 Max. operating pressure MPa Grade 4 1.0 103 0.8 Grade 3 102 0.6 101 Grade 2 100 0.4 Grade 1 10-1 0.2 0 5 0 20 40 60 1 0.1 0.2 Particle size m or less 0.3 0.5 Operating temperature C 15-17-3 4 Series AS-FPQ/FPG How to Order AS 2 1 1 2 F P Q 01 06 Body size 1 2 3 4 M5 standard

R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.) R 3/8 x 100 M16 x l 250 M16 x l 300 M24 x l 500 M16 x l 500 Anchor bolt (4 pcs.) Note 1) Manufactured upon receipt of order Note 2) The accessories should be mounted by user.

If foreign matter such as oil mist or dust is present in the compressed AFF AM Misc. 14-19-3

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B C D E F G H I J A , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3-M5 x 0.8 x depth 6 3-M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 14-13-5

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g