11-LEFG32-S 0.92 1.08 1.23 1.4 1.56 1.72 1.88 2.04 2.20 2.36 2.52 2.88 2.84 3.00 3.16 3.22 11-LEFG40-S 2.07 2.29 2.51 2.72 2.94 3.15 3.37 3.58 3.80 4.01 4.23 4.44 4.66 4.87 5.09 5.30 5.52 5.73 527 11-LEFG Series Dimensions: Ball Screw Drive 11-LEFG16-S 4 x M4 x 0.7 thread depth 6.4 3H9 (+0.025 0 ) depth 3 24 40 (72) 39.4 28 3.5 3H9 (+0.025 0 ) depth 3 (37) A (Table traveling distance) 36

HF Handle position: Left Handle position: Right [mm] Bore size Arm opening angle HF Bore size H HA HD 50 250 61.5 40 63 250 64.5 40 15 36 30 49 45 61 60 73 75 87 90 101 105 114 120 124 50 15 41 30 55 45 68 60 81 75 94 90 107 105 117 120 124 63 5 NAAMS Standards Compliant Power Clamp Cylinder CKZ3N -X2742A -X2568 Dimensions: Clamp Arm Bore Size 50 Clamp Arm Code List Straight: Plain Bore size

Panel mount adapter + Front protective cover Note) These options are unassembled in the factory, but are included with the shipment. 16-3-36 5 Series PSE300 Controller Specifications Conforms to CE marking and UL (CSA) standards.

Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

switch: IR12l0-01lEl-A ITVX 42 PVQ M10 x 1 25 31 7.5 VY1 Mounting hole M28 x 1.5 1.6 VBA VBAT 4.5 2 x 1/8 Port size 90.5 AP100 53.5 45.9 37.6 9.8 OUT IN 30 EXH 57 EXH 2 x 1/8 Pressure gauge port 35 783 IR1200-A/2200-A/3200-A Series Dimensions Basic type (Knob): IR22l0-02l-A 12.5 48 2 Bracket 30 Mounting hole for hexagon panel nut 48 Bracket (Option) 30 Max. 4 Pressure gauge (Option) Panel 36

Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Warning Connection thread Proper tightening torque ( ( ( (N m) Rc1/8 3 to 5 Rc1/4 8 to12 Rc3/8 15 to 20 Rc1/2 20 to 25 Rc3/4 28 to 30 Rc1 36 to 38 Rc1 1/4 40 to 42 Rc1 1/2 48 to 50 Follow the procedure of the manufacturer when fittings other than SMC is used. 4. Piping Make P port piping so that supply air pressure does not become lower than operating pressure while operating.

freezing) (3) marking Model A B + B Ambient and fluid temperature Port size fo connection of pressure gauge Rc 1/8 VFR3100 A side COM Weight (kg) 0.46 VFR3200 A side COM B side Effective area at supply side (mm2) PA 21 18.5 11 VFR3400 3 5 A side COM B side S at P1=0.7 MPa/P2=0.5 MPa PB 18.5 22 12 Applicable terminal Effective area at exhaust side (mm2) AEA 40 1.25-3.5M, 1.25Y-3L, 1.25-3M 36

When instructions are given in the Specific Product Precautions, follow these specifications. 1/2 20 to 25 3/4 28 to 30 1 36 to 38 1 1/4 40 to 42 1 1/2 48 to 50 2 48 to 50 3) If the fitting is tightened with excessive torque, a large amount of sealant will seep out.

OUT port (On both sides) IN port (Axial piping) IN port (On both sides) 18 36 When changing the port location, please order the following plug. Replacement port plug part number: MXH-P (2 pcs.) Material: Ferrite stainless steel, Thickness: 0.3 mm Since the back side is treated with adhesive, it is possible to attach to the cylinder. 2.

258-9200-www.stevenengineering.com VT G: 300 H: 600 (Lead wire length) G, H: 26.1 G, H: 26.8 (For DC) VP 10 VG VP 27.8 (For AC) S070 25.3 21.2 VQ 9 6 A R VKF 5.5 3 3 9.5 5 4 VQZ 19 3-M3 x 0.5 (Piping port) VZ VS L plug connector (L): SY1 4(A)-L-M3 1 2 M plug connector (M): SY1 4(A)-M-M3 1 2 VFN 45.6 (For AC) (Light/Surge voltage suppressor) 15.6 (Light/Surge voltage suppressor) + P P 36

Description Material Note 29 Aluminum alloy Hard anodized 30 Spacer Aluminum alloy Hard anodized 31 Lever Carbon steel Rust proof treatment 32 Piston Stainless steel 33 Bushing Stainless steel 34 Return spring Stainless steel 35 Wear ring Polyurethane 36 Piston seal NBR 37 O-ring NBR 38 O-ring NBR Electroless nickel plating 39 plug Brass (Plug is used for MXQ6,8(C),12(C)) Axial piping type

KQ2L P.36 Use to pipe a male thread of a pressure gauge, etc. Reducer elbow Straight union P.33 KQ2H Female elbow KQ2LF Use to change the tube direction of One-touch fittings by 90 and connect tubing of reduced size. P.36 P.36 KQ2L Use to connect tubing in the same direction. Use to pipe a male thread at right angles.

Therefore, the possible supply current to the sensor is 120 [mA] 84 [mA] = 36 [mA] Use of low-wattage type valves by minimizing the maximum number of simultaneous outputs, and low current consumption sensors (2-wire sensor, etc.) is recommended.

0 3-5-80 81 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR5000 Plug-in 2 position single/double, 3 position closed center/exhaust center/pressure center 0 1 2 position single: VFR510 -F(Z) 21 [25] 32 [39] 40 [40.5] 31 [36] 25 [24] 31 [36] 1 2 31 [41] 16 [19.5] 16 [19.5] EA P EB VK A B 32 [39] 40 [40.5] VZ 5-Rc 3/8, 1/2, 3/4 EA, EB port = Rc 1/2 in case of

Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. Warning Caution How to Use Plug Connectors Manual Override Operation 1. Attaching and detaching connectors Since connected equipment will operate when manual override is performed, firtst confirm that conditions are safe.

5 x 1.5 t5 73.2 36 32 0.28 5t427fi( It_433?96(tR)0tMl.0[l 25.0 38 30 M27x3 t3.2 36 32 0.28 A dimensions in millimeters. Notes: 1. To be lsed wth non-button models on y. 2. Max mum sideoad angle is 30'. I 6ffi. Adjustable Hydraulic Series lmperial Accessories JAM NUT (JN) fttolog llo. P.rt trrbo/ ljlodel 0el) lA JI JH Wsighl [.rJ Jlllill0xl J?44?

the bonnet assembly (1) is a heat resistant structure. 10 High Vacuum Angle Valve Series XLC, XLCV Dimensions (mm) 1in = 25.4mm (b) XLC/Air operated type C D E C E E Fn (KF flange) Fd (K flange) (a) (c) H J Heater (optional) B G A A (mm) H 40 G 17 26 41 52 70 83 Fd Fn 30 40 55 75 87 114 D 1 1 2 2 3 3 C 38 48 66 79 100 117 B 110 120 171 183 209 250 E Note 1) A 40 50 65 70 88 90 J 26 28 36

46 46 15 10.5 19 52 52 52 96.5 17.5 35 22.5 32 22.5 43 61 49 98 65 14 23 55 55 55 103.5 10.5 19 58 58 58 103 17.5 40 25 36 25 46 63 50 101 68 14 23 61 61 61 111 The figures in parentheses are the normally open type. 22 23 Series VX21/22/23 For Water, Oil, Steam/Manifold Dimensions: Manifold/Base Material: Brass, Stainless Steel Normally closed (N.C.): VVX21/VVX22/VVX23 Normally open

Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the mounting screws and brackets may become loose. The product body is made of resin.