SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S32H-6000-A76H"

Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 : Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points

Specifications SL5402 1 to 30 psig (0.007 to 0.2 MPa) SL5410 2 to 100 psig (0.014 to 0.7 MPa) SL5406 1 to 60 psig (0.007 to 0.4 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas Vacuum to 1000 psig (6.9 MPa) 3000 psig (20.7 MPa) 6000 psig (41.4 MPa

Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 87 16 Series LC7R Brake Wiring Example A wiring example for controller (Series LC1) connectors and a brake is shown below. The brake is in a de-energized condition and locked. 24VDC is required to unlock it.

kg) B C D E F G H Nominal size Pitch Compression Tension -X JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250 JB140-22-250 20, 25 32 40 50, 63 80 8 10 16 20 22 1.25 1.5 2 2.5 2.5 51 62.5 80.5 101 129 29 35.5 47.5 59 71.5 13 15 18 24 38 0.15 0.29 0.56 1.04 2.6 8.5 10 16 21 18 11 13 20 26 22 31 41 50 59.5 79 6 7.5 9.5 11.5 14 11 14 19 24 30 11 13.5 16 20 22 22 27 32 41 46 0.75 1 1.25 2 2.5 6000

Y40 14 NAC4000~NAC4040 Y50 14 NAC4000-06~NAC4040-60 Y60 15 NAC5000/5500/6000 NAC5020/5520/6020 L TYPE BRACKET H O W T O O R D E R L T Y P E B R A C K E T Spacer with Bracket Bracket Only 1000 S E R I E S Y10L .B110L 2000 S E R I E S Y20L .B210L 3000 S E R I E S Y30L .B310L 4000 S E R I E S Y40L .B410L 4000-06 S E R I E S Y50L .B510L 5/6000 S E R I E S Y50L .B610L D I M E N S I O N S L T

1) Auto switches with an indicator light (except Model D-A96, A96V, A76H) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to the internal voltage drop in the auto switch specifications.)

Switches with an indicator light (except D-A56/A76H/ A96/A96 V/C76/E76A/Z76) If auto switches are connected in series as shown below, please note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.)

IC circuit 5 V, 12 V Grommet Reed auto switch Solid state auto switch 2-wire 12 V Connector Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V 24 V Grommet 2-wire Water resistant (2-color indicator) 12 V F7BAV F7BA With diagnostic output (2-color indicator) IC circuit F79F 4-wire (NPN) 5 V, 12 V 3-wire (NPN equivalent) IC circuit A76H

Lead wire length (m) Rail mounting 32 to 100 Direct mounting 20 to 100 Load voltage Indicator light Special function Wiring (Output) Pre-wire connector Electrical entry 3 (L) 5 (Z) Applicable load None (N) Type 0.5 (Nil) DC AC Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) A96 A96V A76H IC circuit 5 V A72H A73H A72 A73 Reed switch 200 V Grommet Yes Yes 100 V Relay, PLC

PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 16-11-16 13 For details about certified products conforming to international standards, visit us at www.smcworld.com.

Flow capacity (l/min (ANR)) Oil mist concentration at outlet side 300 750 1500 2200 3500 Filtration (m) Port size Rc Model AM150 AM250 AM350 AM450 AM550 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) , , , , , , , , , 1 1 0.3 1 2 3 4 3 4 1, 1 2 1 , 2 AM650 6000 AM850 12000 1 2 Can produce with auto drain type, drain piping type.

(Page 83) WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 1026 0x0402 0 R/W U16 100 Y Setting of OUT2 delay time at ON 10 ms increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 to 0x1770 (0 to 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 10 ms increment 0: 0.5 sec 1: 1.0 sec 2: 2.0

(Page 85) WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 1026 0x0402 0 R/W U16 100 Y Setting of OUT2 delay time at ON 10 ms increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 to 0x1770 (0 to 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 10 ms increment 0: 0.5 sec 1: 1.0 sec 2: 2.0

Humidity and liquid water Oil Maximum number of particles per cubic meter as a function of particle size d [mm] Mass concentration Cp Pressure dew point Concentration of liquid water Cw Concentration of total oil 0.1 < d 0.5 0.5 < d 1.0 1.0 < d 5.0 [mg/m3] [C] [g/m3] [mg/m3] 0 As specified by the equipment user or supplier and more stringent than class 1 1 20 400 10 70 0.01 2 40 6000

CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able

Pressure Control Equipment Regulator Series AR Regulator Series Application/Characteristics Port size Set pressure (MPa) Miniature regulator ARJ1020F Direct operated relieving style Back flow function M5 0.1 to 0.7 Miniature regulator ARJ210 Direct operated relieving style 0.2 to 0.7 M5 to 1/8 Miniature regulator ARJ310 Direct operated relieving style 0.2 to 0.7 M5 to 1/8 Regulator AR1000-6000

Lead wire length (m) Rail mounting 12 to 63 32 to 63 Load voltage Direct mounting Indicator light Applicable load Pre-wire Type Special function Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC connector Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A76H A96V A96 Grommet Reed switch Solid state switch A93 M9N M9P M9B F9NW

BQ-1 Applicable bore size Weight (g) Note 4) Auto switch mounting brackets and auto switches are shipped together with cylinders. 12 to 20 1.5 BQ-2 32 to 63 1.5 BQ2-012 12 to 63 5 Other Applicable Auto Switches Auto switch type Model Features Electrical entry (Fetching direction) D-A73 Grommet (Perpendicular) Without indicator light D-A80 Reed D-A73H, A76H Grommet (In-line) Without indicator

Switches with an indicator light (except D-A56/A76H/ A96/A96 V/C76/E76A/Z76) If auto switches are connected in series as shown below, please note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.)

IC circuit 5 V A76H A96V A96 Yes A72 A73 A80 A72H A73H A80H 200 V Solid state switch Reed switch Grommet 100 V 12 V IC circuit A90V A93V A90 A93 5 V, 12 V 12 V 12 V No Relay, PLC 2-wire 24 V Yes Connector A73C A80C A79W F7NV F7PV F7BV J79C F7NWV IC circuit 5 V, 12 V No Grommet Diagnostic indication (2-color display) Yes 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F9NV F9PV F9BV M9N M9P M9B 5 V,