SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S25H-2000-F79Z"

4000 6000 0 0 0 200 400 600 800 1000 1000 2000 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) VH600 Effective area S = 194 mm2 Supply pressure MPa Supply pressure MPa 0.7 0.7 Valve output pressure (MPa) 0.6 0.6 0.5 0.5 0.4 0.4 0.2 0.3 0.3 0.2 0.1 0.1 0 5 10 15 Flow rate (m3/min (ANR)) 5-8-8 Hand Valve Series VH Construction VH200 8 5 6 4 3 1 7 9 SA 1 (P) VA 4 (B) 2

AL AW AG AV AF800 AF900 369 Series AW10 to AW60 Series AW20K to AW60K Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AW10 Rc 3/8 AW30(K) AW40(K)-06 Rc 3/4 M5 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 1000 Flow rate (l/min (ANR)) 0 3000 4000 1000 2000 0 150 125

Technical data 291 Series MB Allowable Kinetic Energy Theoretical Force (Unit: N) OUT IN 2000 1.0 Rod diameter (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) 125 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.9 1000 100 804 OUT 643 563 482 402 322 241 161 724 804 32 12 80 691 IN 553 484 415 346 276 207 138 622 691 500 300 400 1257 OUT 1006 880 754 629 503 377 251 1131 1257

(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

Ball Bushing Bearing: MGGL Stroke 3000 P=0.5 MPa 2000 MGGL100MGGL801000 MGGL63MGGL50500 MGGL40MGGL32100 MGGL25MGGL2050 10 0 50 100 150 200 Eccentric distance from center of cylinder to load center of gravity l (mm) (Set the maximum allowable load so that it does not exceed the following percentages of the theoretical output: 40% for 20, 50% for 25, and 60% for 32, 40, 50, 63, 80 and 100.)

(initial value) Vibration resistance: No malfunction when tested with one sweep of 45 to 2000 Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) Note 3) Refer to Best Pneumatics No. 1 for details on valves.

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., ETHERCAT, JSY3000-L (128 OUT), SERIAL TRANSMISSION SYSTEM, 645, 200.00000 lb

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., ETHERNET IP, JSY3000-L (128 OUT), SERIAL TRANSMISSION SYSTEM, 645, 200.00000 lb

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., IO-LINK, JSY3000-L (128 OUT), SERIAL TRANSMISSION SYSTEM, 645, 200.00000 lb

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., PROFINET, JSY3000-L (128 OUT), SERIAL TRANSMISSION SYSTEM, 645, 200.00000 lb

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., ETHERCAT, PNP (32 OUT), SERIAL TRANSMISSION SYSTEM, 645, 200 lb

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, PROFISAFE, 32O, SERIAL TRANSMISSION SYSTEM, 645, 200 lb

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., VACUUM MANIFOLD SI UNIT, SERIAL TRANSMISSION SYSTEM, 645, 150 lb

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.