The ION/HV LED on the front panel turns ON (green) during normal discharge.
When the LED is ON (red), this indicates a high-voltage error has occurred.
The main cause of this is usually foreign matter or water droplets adhering to the emitter (electrode needle).
Remove the cartridge and clean the emitter after stopping the power supply and air supply.
For details on how to clean