Do not install piping to the product with a misalignment. A permanent load will be applied to the product after piping. When a flexible hose is used for the piping, the hose must be fixed with a bracket etc.
Be sure to adopt a reliable connecting method if the rotary table is used very frequently or if it is used in a location that is exposed to a large amount of vibrations. Consider the possibility of a reduction in the circuit air pressure caused by a power failure.
Be sure to adopt a reliable connecting method if the rotary table is used very frequently or if it is used in a location that is exposed to a large amount of vibrations. Consider the possibility of a reduction in the circuit air pressure caused by a power failure.
Consider the possibility of a reduction in the circuit air pressure caused by a power failure. When a rotary actuator is used as clamping mechanism, there is a danger of workpiece dropping if there is a decrease in clamping force, due to a drop in circuit pressure caused by a power failure.
0 A !3 !2 !1 o i t !0 !3 !2 !1 o i e t !0 A A e u w y q B C P2 P1 OUT IN P1 w y u B q w y u B q P2 OUT C C IN VXD2272/2382/2392 (32A to 50A) VXD2270/2380/2390 (32A to 50A) !4 !5 !3 !1 i t e !2 !0 A r u B y q !3 !2 !1 i t e o !0 A r u B y q w o w C C Operation
ARJ AR425 to 935 Air-operated type Pilot pressure VBA11A VBA10A, 20A, 40A, 43A ARX Drive chamber A Governor Drive chamber A Governor Drive chamber B Booster chamber A AMR IN (Inlet) IN (Inlet) Drive chamber B ARM VBA22A, 42A Piston rod Piston rod ARP Booster chamber A IR-A Piston Piston IR Check valve Booster chamber B Booster chamber B Check valve IRV Switching valve Switching valve E OUT
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
As a result, it could pose a hazard to humans and damage the machinery and equipment. (5) Do not place a magnetic object near the product. The auto switch is a magnetic sensing type.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
A Devise a safe system so that if a person engages the emergency stop, or if a safety device is tripped during a system malfunction such as a power outage, the movement of the cylinder will not cause a hazard to humans or damage the equipment. Avoid synchronized operation using cylinders only.
To prevent danger and damage due to a breakdown or malfunction of these products, which may occur at a certain probability, a backup system should be arranged in advance by using a multiple-layered structure or by making a fail-safe equipment design, etc. 13. Avoid heat radiation from strong heat sources, such as direct sunlight or a hot furnace.
Thermo-con. (1) Flow rate of recirculating fluid is a little.
Then install a nipple and a heavy duty auto drain. Install with out port" down in a vertical position.
C0.5 file chamfer AL B MM R sphere TP R sphere DC 30 H W1 T H H H Symbol: A12 Symbol: A13 Symbol: A14 Symbol: A15 30 C 30 DA DA C0.5 R sphere DA DA C AL MM 30 A H T W1 A H C A H H Symbol: A16 Symbol: A17 Symbol: A18 Symbol: A19 MM 30 MM 30 DA MM 30 AL MM 30 H A H A A C H A H Symbol: A20 Symbol: A21 Symbol: A22 Symbol: A23 DA 30 30 DA L RD 30 MM 30 MM MM DB DB T T C B A H A A A L K H W H H
Ventilation Provide ventilation when using a valve in a confined area, such as in a closed control panel.
Applied voltage When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil damage. M5 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/6 to 1/4 turn. As a reference value, tightening torque is 1 to 1.5 Nm.
Do not use the lock as a safety lock or a control that requires a locking force. The lock used for the product with a lock is designed to prevent dropping of work piece. 2. For vertical mounting, use the product with a lock. If the product is not equipped with a lock, the product will move and drop the work piece when the power is removed. 3.
AD27-6-A With bowl guard AD27-6C-A AD37m-6-A AD47m-6-A Normally open (N.O.) With bowl guard AD38m-6-A AD48m-6-A Automatic (Auto drain) Manual With drain cock C2SF-2-A C3SF-2-A C4SF-2-A With level gauge C3LF-8-A C4LF-8-A With drain guide (without valve function) C2SFm-2J-A C3SFm-2J-A C4SFm-2J-A With level gauge C3LFm-8J-A C4LFm-8J-A Metal Normally closed (N.C.)