MH*-OMM0057 MHL2-10D* MHL2-16D* MHL2-20D* MHL2-25D* MHL2-32D* MHL2-40D* 1. 23 2. 4 3. 3-1 5 3-2 5 3-3 5 3-4 67 3-5 8 3-6 9 3-7 1012 3-8 13 4. 4-1 13 4-2 14 4-3 15 4-4 16 1 - *1) (ISO/IEC) (JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment
No.MH*-OMZ0005 / / JMHZ2-16D-X7400B-(HC10/HC10DT)-(N/P) . 2 1. . 4 2. . 5 3. . 6 3-1. . 6 JMHZ2-16D-X7400B-HC10 . 6 JMHZ2-16D-X7400B-HC10DT . 6 3-2. . 7 3-3. . 8 3-4. . 9 3-5. . 10 JMHZ2-16D-X7400B-HC10-(*) . 10 JMHZ2-16D-X7400B-HC10DT-(*) . 11 3-6. . 12 3-7. . 13 JMHZ2-16D-X7400B-HC10-(*) . 13 JMHZ2-16D-X7400B-HC10DT-(*) . 13 4 . 14 4-1. . 14 4-2. 3 . 15 4-3. . 16 5. . 17 5-1
Tightening torque Bore size Socket Tightening torque[Nm] 40,50 13 (M8) 7.4 63 17 (M10) 20 80,100 19 (M12) 29 2 4 Tie rod tightening order. 14 3-2-2. Removal of seals 1) Rod seal Insert a precision screwdriver from the front of the cover to pull out the seal as shown in Fig. 4.
Do not remove the name plate. 13. Perform periodic inspections and confirm normal 1. These products are intended for use in general factory EX500/EX250/EX126 Precautions automation equipment.
No.EX-OMM0008-D PRODUCT NAME Fieldbus system (SI unit compatible CompoNetTM) MODEL / Series / Product Number EX12#-SCM# Table of Contents Safety Instructions 2 Product Summary 7 Model Identification and How to Order 7 Summary of Product parts 8 Mounting and Installation 13 Wiring 13 Setting 18 Mounting of Objects 20 Maintenance 27 Troubleshooting 28 Specifications 31 Specifications 31 Dimensions
Wiring of the power supply cable . 13 3-2-3. Wiring of the AC adapter . 13 3-3. Timing chart . 14 4. Function . 14 4-1. Name of Parts . 14 4-2. Adjustment of offset voltage (ion balance) . 15 4-3. Adjustment of air flow . 15 4-4. Maintenance Warning Function and Cleaning . 15 4-5. Replacement of Cartridge Case . 17 4-6. Alarm function . 17 5. Performance . 18 6. Dimensions . 19 7.
(Refer to Page 13 to 14) 22 - Change to recommended balanced circuit. (Refer to Page 13 to 14) b. Adjust the regulator valve. Check if the locked status is balanced. c. Install an air tank so that pressure fluctuation does not occur when supplying air to the lock unit and cylinder. d. After stopping by locking, release the lock after waiting for 0.5sec or longer. a.
Decline in the power supply voltage (13) (7) AC voltage was applied to a DC pilot valve. 13 VEX-OMT0003 Countermeasures No. Countermeasures (1) Connect wires correctly. (2) Replace the parts. (3) Replace the parts or connect wires correctly. (4) Replace the valve. (5) Adjust the pressure so that pilot pressure is within the specified range during operation.
Wiring . 13 3-2-1. Connection Circuit . 13 3-2-2. Wiring of the Power Supply Cable . 15 3-2-3. Wiring of the AC Adapter . 15 3-3. Timingchart . 16 4. Function . 17 4-1. Name of Parts. 17 4-2. Adjustment of Offset Voltage . 17 4-3. Adjustment of Air Flow . 18 4-4. Emitter Dirt Detection and Cleaning. 19 4-4-1. Manual Cleaning . 19 4-4-2.
Apply grease all over the seal and inner surface of the bushing as shown in Fig. 13. If it is difficult to apply grease, for example to a small bore diameter, use a precision screwdriver. Do not scratch any surface with the screwdriver. 2) Piston seal (Fig. 12, ) Mount with care not to twist the piston seal.
Additional Weight Ensuring Safety Unit: g Caution 12 13 16 32 20 100 25 100 32 200 40 200 50 350 63 350 Bore size (mm) With arm Rod flange (including mounting bolt) If one side of the piston is pressurized by supplying air with the clamp arm attached, the piston will move vertically while the clamp arm rotates.
Inch size Metric size 3.2 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 With One-touch fittings Use 1/8" tube. 15-9-72 2 Speed Controller with One-touch Fittings Panel Mount Type, In-line Type Needle Valve/Flow Characteristics AS1001F AS2001F AS2051F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR))
Weight (g) d T H D1 D2 D3 L1 L2 L3 Model 4 ASD230FM-M5-04 9.3 29.4 12 17.5 12.9 29.6 33.8 28.8 7.8 11.7 9.6 10 34.6 M5 x 0.8 8 30.1 25.1 6 ASD230FM-M5-06 11.6 32.5 13 13.7 20.6 34.6 6 ASD330FM-01-06S 14 39.6 11.6 29 13.7 38.5 22.9 36.1 31.1 10.6 14.2 11.8 12 32.1 27.1 R 1/8 15.8 33.9 8 ASD330FM-01-08S 38.9 15.2 31 18.5 44.8 28.2 6 ASD430FM-02-06S 12.8 53 17 43.5 25.2 18 8 ASD430FM-02-08S
Refer to pages 13 through 15 for actuator safety instructions and precautions. Selection Mounting Caution Caution 1. Use the cylinder within its load limitation. Select a model taking into consideration the allowable horizontal loads, rotation torque and eccentric loads that will apply.
13 Open F A B C D E F G H 40 70 90 J 98 152 192 Model MHL2-16D MHL2-16D1 MHL2-16D2 45 75 95 60 90 110 28 58 78 68 110 130 98 170 210 128 200 240 26 50 70 Notes) J dimension is at fully closed position.
15.5 8 0 -0.05 2 MHT2 2 3.5 0 -0.03 3.5 0 -0.03 MHY2 Open: 22 Closed: 14 MHW2 2-M3 X 0.5 thread depth 6 (Thread for mounting attachment) MRHQ Auto switch 15 15 6 5 5 6 2.3-12 Series MHR2/MDHR2 20 Without Auto Switch: MHR2-20R 57 54 3-M4 X 0.7 thread depth 8 B MHR2-20E port position P.C.D36 (Mounting thread) 60 120 o 14 120o A C 45 M5 X 0.8 Finger opening port M5 X 0.8 Finger closing port 13
Note VZ2000-37A-2 For VZ22 AN120-M5 Noise reduction: 18 dB or more (8 x 17l ) AN110-01 Noise reduction: 21 dB or more (13 x 38l ) Description M5 R 1/8 (2) Silencer Note 1) For body ported type Note 2) For sub-plate mounted type 4-15-1 2 Series VZ200 How to Order Option M5 1 2 VZ2 G 1 Foot bracket F Silencer U Foot bracket + Silencer K Series VZ200 Only body ported type Type of actuation
For Safety Instructions and Splenoid Valve Precautions, refer to page 3-13-2. Mounting Caution 1. SUP port and EXH port are positioned on both sides of manifold block. Air can be supplied from either side; however, the unused port must be plugged in this case.
Note 13) A bowl guard is provided as standard equipment (nylon).
side 1 2 3 4 5 D side VQ 6 barb fitting 3 (EXH) port VKF (18) 12 VQZ 7 3.5 5 5 3.2 3.5 VZ P = 7.2 12.8 n-3.2, 4 barb fitting 2 (OUT) port VS VFN Dimensions Formulas: L1 = n x 7.2 + 14.8, L2 = n x 7.2 + 18.4, n: Stations (maximum 20 stations) n L 12 101.2 104.8 19 151.6 155.2 2 29.2 32.8 3 36.4 40 4 43.6 47.2 5 50.8 54.4 6 58 61.6 7 65.2 68.8 8 72.4 76 9 79.6 83.2 10 86.8 90.4 11 94 97.6 13