Since the marked point is below the curve for 50 l/min (ANR), the maximum rate will be about 50 l/min (ANR).
I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10 15.5 1.5 1.6 13 23 14 25 36 16 25 37 16 24 36 32 40 65 31 39 64
H L M L (mm) H Width across flats Body size Weight g Effective area mm L H Width across flats Min. bore M Applicable hose I.D.
H L M L (mm) H Width across flats Body size Weight g Effective area mm L H Width across flats Min. bore M Applicable hose I.D.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
There are three values the Low Limit (L), Input Value (I), and High Limit (H). These values can be Set Directly, be Analog Inputs, or be Function Block values. The Output can be given a Set or Reset priority. Set Priority The Output turns ON when the Input Value is equal to or between the High and Low Limits.
Table (3) Rated Voltage/Electrical Option Solenoid valve (Port size) Orifice symbol (Diameter) S Class B Rated voltage 1 (2 mm) 2 (3 mm) 3 (4.5 mm) 4 (6 mm) 5 (8 mm) L Z VXK21 VXK22 VXK23 Model Voltage symbol Voltage With surge voltage suppressor With light and surge voltage suppressor With light AC/ DC 01 (1/8) 02 (1/4) Port symbol (Port size) 1 2 3 4 7 8 J 5 6 100 V 200 V 110 V 220 V 240
"-"()7 D Digit () 1 digit=0.01 MPa 0.01 MPa 0.01,0.02,,0.99,1.00 F 01[MPa] F.S.=1-0=1[MPa] (1F.S.=10.01=0.01[MPa]) F.S.
( DXT170-123-ALmm 1) 300 (+-) 6 600 10 1000 15 1500 20 2000 2) 25 2500 (1mm) 30 3000 8 No.VEX-OMY0001 VEX3 VEX3 12,22,32,42 DIN ACZ DCZ 1) 2) 3) () 4) DC No.1 (+)No.2 (-) () (904 ) 3.57 JISC3306 0.5mm22 3 DIN L,M AC AC DC DC AC DC 3 DIN AC DXT170-176-1 NO.1 NO.2 AC100V 100V DXT170-176-2-01 DC AC200V 200V DXT170-176-2-02 NO.1 AC110V 110V DXT170-176-2-03 (+) NO.1
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" Flow rate l/min (ANR) 1000 680 440 480 420 210 150 INOUT Effective area mm 15.2 10.4 6.7 7.3 6.4 3.2 2.3 Note 1) Flow rate values are at a pressure of 0.5MPa and temperature of 20C.
/4" 5/8" to 3/4" Weight, lbs (kg) 46.3 (21) 49.6 (22.5) 81.6 (37) Dimensions, LxWxH, in (mm) 18.2x6.1x9.1 (463x157x230) 18.2x6.1x9.1 (463x157x230) 22.4x8.1x11.4 (569x206x289) Pump with Explosion Proof Motor, 115V/208-230V, 60 Hz, 1 Phase, cUL Listed. 3046E-01 3086E-01 3166E-01
Flow Pressure characteristics Measuring method schematic 1) With high speed static neutralization cartridge 2) With Energy saving static neutralization cartridge 3) With Energy saving high-efficiency cartridge 600 1000 200 IZS4-2500 IZS4-2500 900 180 IZS4-2500 2320 2320 2320 500 800 160 1900 1900 700 140 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 1900 400 L/min
JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.
Note) L or R shows the left or right of the Nil Rc Port size Symbol Port size Applicable model T NPTF F G 01 1/8B ZFA100 02 1/4B ZFA200 Bracket Set Part No.
OUT OUT 1 1 R1/8, NPT1/8 (With M5 female thread), Rc1/8, G1/8, M5 female thread 4, 6 one-touch fitting Piping OUT OUT 2 2 Features 1 2-Color Display High Precision Digital Pressure Switch How to Order Series ZSE40A(F)/ISE40A Rated pressure range ISE40A 14.5 to 145.0 psi ISE40A 01 X P For positive pressure For vacuum/ compound pressure ZSE40A 01 Y P Made to Order Specifications/Description
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: T (w
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)