No.PS-OMW0002-C PRODUCT NAME High-precision Digital Pressure Switch MODEL / Series / Product Number ISE70-#-AB ISE71-#-AB Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Definition and terminology 10 Mounting and Installation 13 Installation 13 Piping 14 Wiring 16 Outline of Settings [Measurement mode] 18 Pressure Setting 19 3-Step Setting

. *7 With lock only *8 For an actuator with lock, add the power consumption for the lock. 13 Battery-less Absolute Encoder: Electric Actuator/High Rigidity and High Precision Slider Type LEKFS Series Battery-less Absolute (Step Motor 24 VDC) Dimensions: In-line Motor LEKFS25E (102) 64 3H9 (+0.025 0 ) depth 3 Body mounting reference plane (B dimension range)1 4 x M5 x 0.8 thread depth 8.5

Applicable model LVR20 LVR40 LVR50 03 3 x 2 LVR20 LVR40 LVR50 03 1/8" x 0.086" 04 4 x 3 05 3/16" x 1/8" 06 6 x 4 07 1/4" x 5/32" 10 10 x 8 11 3/8" x 1/4" 12 12 x 10 13 1/2" x 3/8" 19 19 x 16 19 3/4" x 5/8" LQ3 Metric size Inch size Symbol Applicable tubing size Applicable model Symbol Applicable tubing O.D.

Stations L1 L2 2 stations 33.5 27.5 11 128 122 12 138.5 132.5 13 149 143 14 159.5 153.5 15 170 164 16 180.5 174.5 17 191 185 18 201.5 195.5 19 212 206 20 stations 222.5 216.5 3 44 38 4 54.5 48.5 5 65 59 6 75.5 69.5 7 86 80 8 96.5 90.5 9 107 101 10 117.5 111.5 645 Series 10-V100 Specific Product Precautions 1 Be sure to read before handling.

Sensors (R) (P) 7.4 3 (13) M plug connector (M) L plug connector: 10-VQD1151-L-M5 M plug connector: 10-VQD1151-M-M5 5 5 5.5 2(B) 4(A) Direct manual override Lead wire length 300 mm 27 Indicator light 17.6 11.2 3 3(R) 9 0.3 3.8 10.9 3.5 5.5 9.1 2 x mounting hole 33.5 28.5 37 38 1(P) 1(P) 5.5 12 4-M5 x 0.8 13 L plug connector (L) (P, A, B, R port) 49 50.5 M plug connector (M) 598 4 Port Direct

8 18 18 4.5 4.5 7 13 8 18 18 22 4.5 4.5 3.5 2.5 14 13 8 9 18 18 29 29 3.5 3.5 4.5 4.5 Auto Switch Mounting When using the solid state auto switch (D-M9), mount it in the illustrated direction.

60 106 (170) 6H9 (+0.030 0 ) depth 7 58 74 6H9 (+0.030 0 ) depth 7 7 A (Table traveling distance) L (86) 13 61 90 13 85 68 53.8 (68) 33.5 31 Vacuum port Rc1/8 n x 6.6 76 B D x 150 (= E) 150 60 Dimensions [mm] Dimensions [mm] Model L A B n D E 11-LEFG40-S-150 354 157 328 4 150 11-LEFG40-S-200 404 207 378 6 2 300 11-LEFG40-S-250 454 257 428 11-LEFG40-S-300 504 307 478 11-LEFG40-S-350 554

14 Meter-in Black zinc chromate plated HNBR NBR NBR NBR NBR U seal Cassette Seal O-ring O-ring O-ring O-ring Spacer Gasket 9 10 11 12 13 14 15 16 17 HNBR NBR NBR NBR NBR NBR NBR, Stainless steel Note 1) Only AS221F-U01 and AS321F-U02 are electroless nickel plated.

4 14-13-13 Series ALD600/900 ALD600-06 to 10, ALD900-12 to 20 D.P. Lube Related Products: Strainer At the terminal of an air pressure line in which a D.P. Lube is used, install a strainer (filtration rate of 5 m) upstream with a metal seal solenoid valve, which is susceptible to dust. Float switch mounting position Mounting orientation is upward.

L dimension 11 148 12 160.5 13 173 14 185.5 15 198 16 210.5 17 223 18 235.5 19 248 20 260.5 No. L dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No.

7 2 5 120 32 82.5 33 286 386 511 611 736 836 7 2 13 120 32 33 5 92 399 524 624 1049 949 749 849 Hexagon socket head cap screw is used for mounting hole. 7 0 185 46 2.5 20 120 29 D-X Technical Data 1169 Air-hydro Converter CCT Series How to Order CCT 63 100 CE-compliant Nil Q CE-compliant (Refer to Table 1.)

ZFB100, ZFB101 ZFB200, ZFB201 ZFB300, ZFB301 ZFB401 16 x 14 x L60 rZFB200-08 tZFB300-08, -10 ZFB301-11, ZFB401-13 I-34S-A 10 x 6 x L33 12 x 8 x L42 14 x 10 x L45 I-35S-A I-36S-A I-39S-A 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. yZFB401-13 Note) Elements and O-rings for the cover are sold in sets of 10 pieces each. 10 pcs.

Please refer to pages 14-20-13 to 14-20-14 for details. Sight glass AFF75B is aluminum casted. Tempered glass Replacement Parts AFF11B Model No.

Select a bore size in accordance with How to Select on page 8-2-12 to 8-2-13. 2. Displacement may increase after an impact load has been applied.

No.PF-OMG0006-F PRODUCT NAME Digital Flow Switch (Remote type sensor unit) MODEL / Series / Product Number PF2D5## Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 13 Installation 13 Piping 14 Wiring 15 Troubleshooting 17 Cross-reference for troubleshooting 17 Specification 18 Specifications

FGDT,F(L250) (7)(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.

Mounting, Operation P.10 1) Operating air P.10 2) Precaution on design P.11 3) Mounting P.13 4) Operating environment P.13 5) Piping P.14 6) Cushion P.15 7) Speed control P.16 8) Direction control P.16 4. Maintenance P.17 1) Inspection P.17 2) Overhaul P.18 3) Disassembly P.18 4) Assembly P.19 5) Expendable supplies P.20 6) Replacement procedure of seal P.21 7) Inspection P.22 5.

CG5A 11~2 2 31 4 5 6 7 13 2-6-3. P101. 2 CG5 N A (mm) E max (J) E max (J) 2 E=(m/2)v 20 0.28 0.42 25 0.41 0.65 E J m: (Kg) v m/s 32 0.66 0.91 40 1.2 1.8 50 2.0 3.4 EE max (J) 63 3.4 4.9 80 5.9 11.8 100 9.9 16.7 (2) 2-7. 14 28. 3 13 2 3CDG5 (M4 1~1.2Nm 3 3.

Basic Construction 16 O-ring NBR 15 Piston seal NBR 14 Rod seal NBR Oil-impregnated sintered 13 Bushing bearing 12.

If the kinetic energy of the load exceeds the allowable value, it could damage the product, and cause a hazard to humans and damage the machinery and equipment. (13) Provide a shock absorber if the kinetic energy that is applied to the product exceeds the allowable value.