Take measures against freezing when operating at 5C or less. Mounting and Adjustment Caution 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (980 m/s2 or more for sensor unit and 98 m/s2 or more for amplifier unit) while handling. Although the trimmer auto switch body may not be damaged, the inside of the trimmer auto switch could be damaged and cause a malfunction.
Take measures to prevent freezing when below 5C, since moisture in circuits can freeze and cause damage to seals and lead to malfunctions. For compressed air quality, refer to Air Preparation Equipment catalog. Winding direction Pipe tape Expose approx. 2 threads 95 Actuator Precautions 3 Be sure to read before handling. For detailed precautions on every series, refer to main text.
225 2A 43 4A 10.8 0B 204 2B 41 4B 10.4 0C 187 2C 40 4C 10 0D 173 2D 38 4D 9.7 0E 160 2E 37 4E 9.4 0F 150 2F 36 4F 9.1 10 140 30 35.2 50 8.8 11 132 31 33.1 51 8.3 12 125 32 31.3 52 7.8 13 118 33 29.6 53 7.4 14 112 34 28.1 54 7.0 15 107 35 26.8 55 6.7 16 102 36 25.6 56 6.4 17 97 37 24.5 57 6.1 18 93 38 23.4 58 5.9 19 90 39 22.5 59 5.6 1A 86 3A 21.6 5A 5.4 1B 83 3B 20.8 5B 5.2 1C 80 3C 20.1 5C
Moisture in circuits can freeze at 5C or below, causing damage to Orings, and malfunction. Consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits. Furthermore, even though the ambient temperature range remains within specifications, do not operate in locations where there are abrupt temperature changes. 2.
of input/output branches Branch cable Branch cable length Communication connector Power connector 200mA or less Maximum 64 inputs/64 outputs 4 branches (16 inputs/16 outputs per branch) 8 core heavy duty cable 5m or less (total extension 10m or less) M12 connector (8 pins, socket) M12 connector (5 pins, plug) Ambient operating temperature/humidity Enclosure Applicable standard Weight g +5C
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and leading to equipment malfunction. Therefore, take appropriate measures to prevent freezing. Refer to SMC Air Preparation System for further details on compressed air quality.
Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance
Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Wrapping direction Expose approx. 2 threads Pipe tape 114 Actuator Precautions 3 Series MY1 Operating Environment Maintenance Warning Warning 1.
Replace the adsorbent according to color of the indicator. 1 4 1 2 1 2 3 4 520 615 850 961 45 45 75 75 9 9 9 9 120 120 170 170 95 95 95 95 59.5 59.5 88 88 128.5 128.5 243.5 243.5 59.5 59.5 66.5 66.5 134.5 134.5 183 183 222 222 302 302 Dew point temperature (Atmospheric pressure) 30C or less 18C 10C 5C Color of indicator ID300 ID400 ID600 Dark blue Light blue Light pink air, the capillary
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to Best Pneumatics No. 5. Cushion Caution 1. Readjust using the cushion needle.
VP7 3 5 Plug-in: SS5Y -Type 45 VQC Q 5 SY 5 1 FU Single solenoid: 5 SQ Q 5C FU Double solenoid: 5 SY 5 1 VQ VQ4 Series Manual override 3 SY300 5 SY500 Nil Non-locking push type VQ5 D Push-turn locking slotted type E Push-turn locking lever type VQZ Type of actuator 1 Normally closed (N.C.) Rated voltage VQD 2 Normally open (N.O.)
Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Best Pneumatics vol.4 catalog for further details on compressed air quality. Piping Caution 1.
Piston rod Table (2) MXP6 MXP10/12/16 L2 L2 L2 (mm) 10 (One side only) 10 (One side only) 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Damage is not allowed. 3. Shock absorber is considered a consumable component. When energy absorption is decreased, replace it.
Take measures to prevent freezing at temperature below 5C, since moisture in circuits may freeze and cause damage to seals and lead to malfunctions. 5. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. Cushion Caution 1.
Rated voltage 2 Normally open (N.O.) 1 100VAC 3 110VAC [115VAC] Solenoid type Nil Single solenoid Pilot type D Double solenoid Nil Internal pilot R External pilot External pilot cannot be used on a type 41P manifold. 3 5 Plug-in: SS5Y -Type 45 5 SY 5 1 FU Single solenoid: 5 5C FU Double solenoid: 5 SY 5 1 Series Manual override 3 SY300 5 SY500 Nil Non-locking push type D Push-turn locking
Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance
Mandrel Here, : Deformation ration (%) d: Tube diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Handling of One-touch Fittings Test temperature: 20 5C Relative humidity: 65 5%. Caution 3. Applicable for general industry water. Please consult with SMC if using other fluids.
7.4 7.0 6.7 6.4 6.1 5.9 5.6 5.4 5.2 5.0 4.9 4.7 4.5 70 66 62 59 56 53 51 48 46 45 43 41 40 38 37 36 35.2 33.1 31.3 29.6 28.1 26.8 25.6 24.5 23.4 22.5 21.6 20.8 20.1 19.4 18.8 18.2 Invalid 2250 1125 750 562 450 375 321 281 250 225 204 187 173 160 150 140 132 125 118 112 107 102 97 93 90 86 83 80 77 75 72 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C
Leakage current 5mA or less Dimensions 80 x 120 x 244mm Weight 2.2kg Actuator control Item Model LC1-1B1V1---X180 LC1-1B1V1---X233 LC1-1B1V2---X180 LC1-1B1V2---X233 Compatible actuator LXSAB-S--X12 LXPAB-S--X12 LXSAB-S--X13 LXPAB-S--X13 Compatible guide High rigidity direct acting guide High rigidity direct acting guide Guide rod Guide rod Motor capacity 30W Operating temperature range 5 to 5C
Plug-in: For SS5Y -45 3 5 VQC VQZ SQ 5 5 SY 5 1 FU Single solenoid: VFS 5 SY 5 1 5C FU Double solenoid: VFR Series CE-compliant VQ7 3 SY300 5 SY500 Nil Q CE-compliant Type of actuation Manual override 1 Normally closed (N.C.) 2 Normally open (N.C.)