°C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: °C, Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: °C), Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

MTS 0.7 20 35 55 79 141 0.6 17 30 47 68 121 0.5 14 25 40 57 101 0.4 11 20 32 45 80 0.3 8 15 24 34 60 28 50 79 113 201 With Shock Absorber Mass Standard Stroke (g) (mm) Body mass 80 105 100 160 130 210 210 320 640 830 Standard stroke 5, 10 10, 20 10, 20 15, 25 20, 30 Model MXP6 MXP8 MXP10 MXP12 MXP16 Model MXP6-5 MXP6-10 MXP8-10 MXP8-20 MXP10-10 MXP10-20 MXP12-15 MXP12-25 MXP16-20 MXP16-30

18 16 24 43 47 40 79 87 85 2.8 5/32 12.7 2.8 6.5 6.5 6.5 11.11 13.6 1/4 H 14.29 17 M 14.29 5/16 18.5 A 14 42 L 17.46 54.2 47.2 49.2 60.5 54.5 17.46 24 3/8 21 22.23 34 1/2 22.23 22 Connection thread Reference dimension after screwing into NPT threads.

Suction cover PVF 1 9 Sound absorbing material B ZL112-SP01 Front cover Without valve PVF 2 10 Sound absorbing material A (set no. for 9, 10 &11) End cover PE 3 11 Suction filter Body 4 When ordering a vacuum pressure gauge or a digital vacuum pressure switch separately, use the part numbers shown in the option specifications on page 3.

N Bracket dimensions With auto-drain Model Port size A B C D E F G H J K L M U (Body) V (Adapter) L 178 211 277 321 B 260 298 366 436 T 9 9 11 11 S 8 16 21 26 R 78 97 98 115 P 50 35 45 46.5 1/4, 3/8 1/4, 3/8, 1/2 1/2, 3/4 3/4, 1 1/4, 3/8 1/4, 3/8, 1/2 1/2, 3/4 3/4, 1 AMR3000 AMR4000 AMR5000 AMR6000 100 120 130 160 180 210 246 290 264 302 370 440 10 10 45 70 101 121 131 161 51 61 66 81 28

Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10

Note 2) Unit: kPa, MPa Panel mount adapter + Front protection cover L Lead wire with connector (Lead wire length 2 m) Note) With connector cover G Connector cover D Note) For output types N and P, the number of core of lead wires will be 3, and for other types, it will be 4. 33 ZSE30A(F)/ISE30A Series Refer to pages 11 and 12 for Pressure Switch Precautions.

EX500-DX B Install the product using 2 M5 screws x 20 mm minimum with a head 9 to 11. NOTE Refer to the product catalog or SMC website (URL http://www.smcworld.com) to obtain more detailed information about product specifications. 1 3 5 7 9 11 13 15 The direct current power supply to combine should be UL1310 Class 2 power supply when conformity to UL is necessary.

Tension bolt Table 3 Guideline of the wing nut tightening amount Model FGES L A FGES L B FGES L C Element size (mm) 65 to 70 250 65 to 70 500 65 to 70 250 65 to 70 750 65 to 70 250 Wing nut tightening amount 26 to 30 40 to 45 33 to 38 51 to 55 27 to 44 Wing nut tightening amount (mm) 11/12 FGX-OM-L008-A 5-4 [Mount O-ring and cover] (1) Set O-ring to the case (2) Rotate the cover clockwise

(mm) 50 30 63 30 80 40 1-4. (mm) (Kg) 50 1.70 / 63 2.78 80 4.96 4 - RS1H 1. mA 2. V(m/min) (Kg) 3.

No.EX-OMN0009-G PRODUCT NAME SI unit for PROFIBUS DP MODEL / Series / Product Number EX260 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 11 Installation 11 Wiring 12 LED Indication and Settings 17 Troubleshooting and Maintenance 25 Specifications 29 Specifications 29 Dimensions 31 Accessories 32 -1No.EX-OMN0009

Operation Patterns 11 6. Characteristics 11 ~ 12 7. Dimensions 13 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Construction / Parts list, seal list Double acting/ Finger open Single acting / Normal open Single acting / Normal close Double acting / Finger close 5 4 12 7 1 9 10 8 16 15 14 3 2 21 11 18 19 13 20 6 17 Components No. Description Material Remarks Components 12 Needle roller High carbon chromium No.

When shipped, the shock absorber is adjusted to the maximum resistance value. 11 - 4. Operation Caution (1) For cylinders with locking mechanism, do not apply external force from the opposite side when the lever is locked.

Stop accuracy Lock unit model MWB*32 MWB*40 MWB*50 MWB*63 MWB*80 MWB*100 Stop accuracy 1.0mm Mounting orientation Horizontal Supply pressure 0.5MPa Piston speed 300mm/s Load condition Upper limit of allowable value Solenoid valve for lock Mounted to the lock release port Value shown is based on testing and the largest value is quoted.

No.PS-OMH0003-F PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ISE70 ISE75(H) Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Piping 14 Installation 14 Wiring 15 Setting and Adjustment 17 Initializing 17 Pressure setting 22 Setting of function 24 Maintenance