SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S32H-6000-A76H"

1) Switches with an indicator light (except D-A76H, A96, A96V) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.)

1) Switches with an indicator light except (D-A56, A76H, A96, A96V, C76 and Z76) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diode. (Refer to internal voltage drop in the auto switch specifications.)

A76H IC circuit 5V Yes Grommet A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H A80H F79 F7P J79 F79W F7PW J79W F7BA F7NT F79F Reed switch Solid state switch 200V 100V 100V or less 12V 5V, 12V Yes NoYes Yes No Relay, PLC 2-wire 24V Connector 5V, 12V 24V or less Diagnostic indication (2-color display) Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5V, 12V Grommet

Grommet (Perpendicular) Without indicator light D-A80 Reed D-A73H, A76H Grommet (In-line) Without indicator light D-A80H D-F7NV, F7PV, F7BV Diagnostic indication (2-color indication) Water resistant (2-color indication) Grommet (Perpendicular) D-F7NWV, F7BWV D-F7BAVL Solid state D-F79, F7P, J79 Diagnostic indication (2-color indication) Water resistant (2-color indication) D-F79W, F7PW

Type Model Features Electrical entry (Fetching direction) D-A73 D-A80 D-A73H, A76H D-A80H D-F7NV, F7PV, F7BV D-F7NWV, F7BWV D-F7BAVL D-F79, F7P, J79 D-F79W, F7PW, J79W D-F7BAL D-F7NTL D-P5DWL Without indicator light Without indicator light Grommet (perpendicular) Reed auto switch Grommet (in-line) Grommet (perpendicular) Diagnostic indication (2-color indication) Water resistance (2-color

Acceleration [mm/s2] 0 250 1 500 2 1000 3 1500 4 2000 5 2500 6 3000 7 4000 8 5000 9 6000 10 7500 11 10 12 12500 13 15000 14 17500 15 20 Note) The factory default setting for the switch is No.0.

(Custom range) Relationship between analogue input and digital display Set value A B 200 0 L/min 200 L/min 500 0 L/min 500 L/min 1000 0 L/min 1000 L/min 2000 0 L/min 2000 L/min 3000(Default) 0 L/min 3000 L/min 6000 0 L/min 6000 L/min 12000 0 L/min 12000 L/min 16000 0 L/min 16000 L/min 20 0 L/min 20 L/min USEr Input value (setting) Input value (setting) -31No.PF-OMU0007-D Press

8000 2000 10 4000 6000 8000 2000 10 4000 6000 8000 2000 10 0 0 0 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Pressure Characteristics (Representative values) Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 l/min (ANR) AC25 AC10 AC20 0.3 Set point 0.25 Set point 0.25 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) Set

8000 2000 10 0 4000 6000 8000 2000 10 0 4000 6000 8000 2000 10 0 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics (Representative values) Conditions: Inlet pressure of 0.7 MPa, Outlet pressure of 0.2 MPa, Flow rate 20 L/min (ANR) AC25-B AC20-B AC10-A 0.3 0.25 0.25 Set point Set point Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure

(page 72) Y U16 0x0064 5 R/W (100) Setting of OUT1 delay time at ON. 0x0 ~ 0x1770 (0 ~ 6000) 0.01 s increment dtH1 (OUT1 delay time at ON) Y U16 0x0 6 R/W (0) dtL1 (OUT1 delay time at OFF) Setting of OUT1 delay time at OFF. 0x0 ~ 0x1770 (0 ~ 6000) 0.01 s increment Y U16 0x0 7 R/W (0) OUT1 Accumulated threshold value setting (L) Consider the accumulated inclination when reading or writing

Recommended torque: 12 to 14 Nm. 231 MR Unit (Regulator with Mist Separator) AMR3000 to 6000 Replacement Procedure is P.448 Construction !1 t OUT IN u MC cartridge element Flow hole A Separation element i y Auto-drain type o !0 r Port size 1/4 Drain The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series AMR.

Recommended torque: 12 to 14 Nm. 231 MR Unit (Regulator with Mist Separator) AMR3000 to 6000 Replacement Procedure is P.448 Construction !1 t OUT IN u MC cartridge element Flow hole A Separation element i y Auto-drain type o !0 r Port size 1/4 Drain The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series AMR.

Humidity and liquid water Oil Maximum number of particles per cubic meter as a function of particle size d [mm] Mass concentration Cp Pressure dew point Concentration of liquid water Cw Concentration of total oil 0.1 < d 0.5 0.5 < d 1.0 1.0 < d 5.0 [mg/m3] [C] [g/m3] [mg/m3] 0 As specified by the equipment user or supplier and more stringent than class 1 1 20 400 10 70 0.01 2 40 6000

rate (l/min (ANR)) Thread type Nil N F Rc NPT G AK4000-03/-04 AK6000-06/-10 Port size 0.5 MPa 0.5 MPa Port size Applicable series AK2000 AK2000/4000 AK4000 AK4000 AK6000 AK6000 Inlet pressure: 0.1 MPa Inlet pressure: 0.1 MPa 0.3 MPa 0.3 MPa 0.7 MPa 0.7 MPa 01 02 03 04 06 10 1 8 1 4 3 8 1 2 3 4 1 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 15-14-1 Series AK Construction AK2000 AK4000/6000

Weight (g) D-A72H D-A73H D-A76H D-A80H Auto switch model 0.5 m (Nil) 3 m (L) 5 m (Z) 10 47 10 47 11 52 10 47 77 Lead wire length Dimensions (mm) D-A7H, D-A80H 8 3.2 7 4 15 SMC Indicator light D-A80H without indicator light 22 2 DD3.4 6.2 3.3 10.2 Most sensitive position 8.5 1637 Reed Auto Switch Rail Mounting Style D-A73C/D-A80C Refer to SMC website for the details of the products conforming

F7NV F7PV F7BV J79C F7NWV F7BWV 3-wire (NPN) 3-wire (PNP) 5V, 12V Grommet 2-wire 12V Connector 10 15 3-wire (NPN) 3-wire (PNP) 24V IC circuit Diagnostic indication (2-color indication) 5V, 12V Yes Yes Yes Yes No No No 15 Relay, PLC 25 25 Grommet 12V 2-wire Water resistant (2-color indication) F7BA F7BAV With diagnostic output (2-color indication) IC circuit F79F 4-wire (NPN) 5V, 12V A76H

F7NV F7PV F7BV J79C F7NWV F7BWV 3-wire (NPN) 3-wire (PNP) 5V, 12V Grommet 2-wire 12V Connector 10 15 3-wire (NPN) 3-wire (PNP) 24V IC circuit Diagnostic indication (2-color indication) 5V, 12V Yes Yes Yes Yes No No No 15 Relay, PLC 25 25 Grommet 12V 2-wire Water resistant (2-color indication) F7BA F7BAV With diagnostic output (2-color indication) IC circuit F79F 4-wire (NPN) 5V, 12V A76H

NPN) IC 5 V A76H A96V A96 C J G5-S Reed switch Solid state switch Grommet A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F P5DW 200 V A93V M9NV M9NV M9NV F9NWV F9PWV F9BWV A93 M9N M9P M9B F9NW F9PW F9BW F9BA Yes Yes CV 12 V 100 V Relay, PLC 2-wire 24 V Connector 12 V MVGQ Grommet Diagnostic indication (2-color) 3-wire (

Lead wire length (m) * Applicable Indicator light Load voltage Auto switch model Pre-wire Special function Type Wiring (Output) Electrical entry connector Perpendicular 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC load In-line 5 V 3-wire (NPN) A76H IC circuit Reed switch Solid state switch 200 V Grommet A72 A72H Yes Yes 100 V A73 A73H Relay, 12 V 2-wire 24 V Connector A73C PLC Diagnostic indicator

(Page 47) WH1 (Window comparator hysteresis) Setting of OUT1 hysteresis (Window comparator) 5 R/W U16 400 Y Settable values 0x0 to 0x1770 (0 to 6000) 6 R/W dt1 (Delay time) U16 0 Y Setting of OUT1 delay time 10 ms increment -43No.PF-OMX0007-A Product individual parameters (continued) Data Data Index Sub Access Initial value type storage 1 Parameter Set value 4 Remarks index 2 3 dec hex 0: