SMC Corporation of America
Elite Part Number Search
Search Results "LEY32C-100F"

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.

. -45- 6 /250km /500 1. 2. 3. 2 LEY16*A 2,000km LEY25*A 2,500km LEY32A 4,000km LEY16*B 1,000km LEY25*B 1,200km LEY32B 2,000km LEY16*C 500km LEY25*C 600km LEY32C 1,000km a. b. c. d. e. f. -46- 7.5. 1. 2. (1mm ) 3. 4. N Nm LEY16 LE-D-2-1 10 0.36 LEY25 LE-D-2-2 19 0.63 LEY32 LE-D-2-3 30 1.5 5. LEY32 Nm LEY16 0.63 LEY25 1.5 LEY32 5.2 6. -47- 8.

Refrigerant R134a (HFC) IDU E IDF 100F 30 W Water-cooled Nil C G K P R V 4 5 Size Size Air compressor size *1 Piping direction 100F 100 kW 125F 125 kW 150F 150 kW Symbol Description 4 Facility water piping direction: Right *1 Refrigerant R407C (HFC) IDU E 5 Facility water piping direction: Left *1 *1 Note that the above values are for reference only.

IDFB4E to 15E 1.6 [40] Air Flow Capacity 2.36 [60] IDFB4E Model IDFB3E IDFB6E IDFB8E IDFB11E D Circuit breaker 5 SCFM (8 m3/h) 13 SCFM (23 m3/h) 17 SCFM (29 m3/h) 19 SCFM (32 m3/h) 23 SCFM (39 m3/h) Air flow capacity (ANR) A C Conditions: Inlet air pressure: 100 psi (0.7 MPa), Inlet air temperature: 100F (37.8C), Outlet air temperature: 50F (10C), Ambient temperature: 100F (37.8C) B E Power

changes : ambient temperature F 80 90 100 110 115 factor 1.09 1.06 1.00 0.90 0.83 Correction factor for inlet air temperature changes : air temperature F 90 100 110 115 factor 1.15 1.00 0.86 0.78 Correction factor for dew point changes : DewPoint F 37.8 39.2 41.0 42.8 44.6 46.4 48.2 50.0 factor 1.00 1.02 1.05 1.07 1.10 1.12 1.15 1.18 * The DewPoint refers to an ambient temperature of +100F

Additional weight with magnet. .0.02 0.12 + 0.05 x 100/50 + 0.022 + 0.02 = 0.262 kg Calculation: (Example) JCMBZ25TR-100F Basic weight.0.10 (Basic (Female thread on rod cover), Rc1/8 port, 25) Additional weight.0.05/50 mm stroke Cylinder stroke.100 mm stroke 0.10 + 0.05 x 100/50 = 0.20 kg Allowable Kinetic Energy Allowable Lateral Load at Rod End fR Table (1) Max.

0.1) (10) Q : Flow rate [kg/h] Kv : Flow coefficient [m3/h] P : Pressure difference [MPa] P1 : Upstream pressure [MPa]: P = P1 P2 P2 : Downstream pressure [MPa] 230 Solenoid Valve Flow Rate Characteristics VXS Series Conversion of flow coefficient: Kv = 0.865 Cv (11) VX2 Here, Cv factor: Value of the clean water flow rate represented by US gal/min that runs through the valve at 40 to 100F

VACUUM SWITCH SERIES ZS VACUUM SWITCH SERIES ZSE1 Solid State Quick Response 10 ms Compact Size Semiconductor Type Pressure Sensor NPN and PNP Versions D I M E N S I O N S V A C U U M S W I T C H S E R I E S ZSE1 G R O M M E T T Y P E T E C H N I C A L SPECIFICATIONS Fluid Air Setting pressure range 0~760mmHg / 0~30inHg Hysteresis Adjustable 1~10% of range Accuracy 3% F.S. (5~40C) 40~100F

Lead 5: LEY32C 40 60 Lead 10: LEY32B Regenerative resistor area Work load [kg] Work load [kg] 30 Lead 10: LEY32B 40 Lead 20: LEY32A 20 Lead 20: LEY32A 20 10 0 0 0 200 400 600 800 1000 1200 1400 0 200 400 600 800 1000 1200 1400 Speed [mm/s] Speed [mm/s] LEY32DV7 (Motor mounting position: In-line) Vertical Horizontal 60 80 Lead 4: LEY32DC Lead 4: LEY32DC 50 Regenerative resistor area 60 Lead

SpeedVertical Work Load Graph LEY25l (Motor mounting position: Top/Parallel, In-line) 40 Lead 3: LEY25C 30 Work load [kg] 20 Lead 6: LEY25B 16 Lead 12: LEY25A 10 8 0 0 200 600 1000 1400 Speed [mm/s] LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC 50 Lead 5: LEY32C 40 46 37 40 Work load [kg] Work load [kg] 30 30 Lead 8: LEY32DB

0.1) (10) Q : Flow rate [kg/h] Kv : Flow coefficient [m3/h] P : Pressure difference [MPa] P1 : Upstream pressure [MPa]: P = P1 P2 P2 : Downstream pressure [MPa] 160 Solenoid Valve Flow Rate Characteristics VXD Series Conversion of flow coefficient: Kv = 0.865 Cv (11) VX2 Here, Cv factor: Value of the clean water flow rate represented by US gal/min that runs through the valve at 40 to 100F

JXC-OMU0029-A LEY32A / LEYG32A LEY32B / LEYG32B LEY32C / LEYG32C Speed [mm/s] Acceleration Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] [mm/s2] 0 24 200 12 200 6 200 1 32 300 19 300 15 300 2 40 400 23 400 20 400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120

coefficient [m3/h] DP : Pressure difference [MPa] P1 : Upstream pressure [MPa]: DP = P1 P2 P2 : Downstream pressure [MPa] 57 Solenoid Valve Flow Rate Characteristics JSX/JSXm Series Flow Rate Characteristics JSX Series Conversion of flow coefficient: Kv = 0.865 Cv (11) Here, Cv factor: Value of the clean water flow rate (represented by US gal/min) which runs through a valve at 40 to 100F

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com BT-04 BT-04 BT-06 BT-08 BT-08 Calculation: (Example) CA2LQ40-100F (Axial foot style, 40, 100 st) Basic weight . 1.08kg Additional weight . 0.22/50 st D-A3/A44 Cylinder stroke . 100 st BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M D-G39/K39 1.08 + 0.22

(If over No. 10 SAE oil or 100 SSU at 100F) Other (CSA, FM, etc.) . . . . . . . . . . . . . . . . . . . . . . . . . . . Form completed by: Name . . . . . . . . . . . . . . . . . . . . . . . . .Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VACUUM SWITCH SERIES ZS VACUUM SWITCH SERIES ZSE1 Solid State Quick Response 10 ms Compact Size Semiconductor Type Pressure Sensor NPN and PNP Versions D I M E N S I O N S V A C U U M S W I T C H S E R I E S ZSE1 G R O M M E T T Y P E T E C H N I C A L SPECIFICATIONS Fluid Air Setting pressure range 0~760mmHg / 0~30inHg Hysteresis Adjustable 1~10% of range Accuracy 3% F.S. (5~40C) 40~100F