SMC Corporation of America
Elite Part Number Search
Search Results "RS2H50-30TM-DC"

No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type) , Possible to use in vacuum or under low pressure, Poppet type valve, 3 PORT SOLENOID VALVE, 1 lb

ON Holds the output. 24 VDC, 1.0 W or less, DC General per output Output rating After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.

Intermediate reinforcing brace (EX600-ZMB1) Output Solenoid valve with surge voltage suppressor of 24 VDC, 1.0 W or less, DC General per output (manufactured by SMC) Settings1 Connected load and output rating Content 1 Hold/Clear/Forced ON Fail safe OFF Output is OFF. (default setting) DIN rail mounting (Not available for SY series valves.

The output rating is tested as a DC output for General use. : Refer to "Parameter Setting", for the further details. (2)Mount the end plate bracket (EX600-ZMA2) to the end plate at the opposite end to the valves, using 2-M4 x 14 screws. Tightening torque: 0.7 to 0.8 Nm.

The output rating is tested as a DC output for General use. (2)Mount the end plate bracket (EX600-ZMA2) to the end plate at the opposite end to the valves, using 2-M4 x 14 screws. Tightening torque: 0.7 to 0.8 Nm. Maintenance End plate bracket (EX600-ZMA2) Maintenance should be performed according to the Safety Instructions. Perform regular maintenance and inspections.

Caution: Solenoid valve with surge voltage suppressor of 24 VDC, 1.0 W or less, DC General per output (manufactured by SMC) Assembling the unit as a manifold (1)Connect a unit to the end plate. Digital and Analogue I/O units can be connected in any order. Tighten the joint brackets to a torque of 1.5 to 1.6 Nm.

Description Item ON US1 is present (> approx. 21.6 VDC). 350 mA or less (EX245-FPS1) 300 mA or less (EX245-FPS2/3) Internal current consumption at 24 VDC (via US1) US2 Indicator NOTE US2 Meaning Reverse Polarity Protection Included (US1 and US2) For UL conformity a DC power supply meeting the requirements of UL1310 Class 2 must be used.

[P_2] Set value 2 Lever Blue DC(-) : The table shows the specifications when a flow adjusting valve is included.

Square groove Blue DC(-) Peak / Bottom value display Zero Clear Key lock function To set each of these functions, refer to the SMC website (URL http://www.smcworld.com) for more detailed information, or contact SMC.

Blue DC(-) DIN rail mounting (using ZS-33-R ) Mount the DIN rail mounting parts using DIN rail mounting screws and joint screws supplied. The required tightening torque of the DIN rail mounting screws and joint screws is 0.40.05 Nm. Connector for electrical connections.

Spring washers L K Connector pin numbers Wire colour Description S L Function selection mode Joint screws J M 1 Brown DC(+) M DIN rail mounting screws Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. In measurement mode, press the S button for 2 seconds or longer, to display [F 0].

Colour Content Caution Brown DC(+) Black OUT( Analogue output) Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result. Blue DC(-) After maintenance is complete, perform appropriate functional inspections and leak tests.

Input of the Set point 2 L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-2, ft3 x 10-1, gal(US)/min, gal(US) 1 Brown DC(+) Non-Reverse output Reverse output Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out dimensions.

When the Upper temperature limit alarm and the DC power voltage alarm go off simultaneously, D2 will be 23X1+22X0+21X0+20X1=9(=39H). HEC 4-4 Details of Communication Format 4-6 Reading temperature average data Note) For this product, the average temperature data, Tm, indicates the temperature of the external sensor.

PID parameters are set incorrectly. setting Cause / Measure DC output voltage of product is reduced. Check the power voltage. Code Description Manner of reset ERR19 Abnormal auto tuning alarm Stop Overloaded during auto tuning mode Avoid overload. ERR02 System error 2 Stop The FRAM data was destroyed by highlevel noise.

Current limiting Power supply current Power supply voltage for pulse signal resistor R type limiting resistor 24V DC 10% 3.3k 5% (0.5W or more ) LEC-PA-R-332 5 VDC 5% 390 5% (0.1W or more ) LEC-PA-R-391 NPN type (LECPAN-) Power supply for pulse signal Inside of the driver Positioning unit side NP+ <3> 1k NP<4> 120 Current limiting resistor R PP+ <5> 1k PP<6> 120 Current limiting resistor

Connector 9 - (6) Power supply Supply power 24V DC. Caution Supply power first to the controller (LEC), then to the gateway unit. If power is supplied to the gateway unit and then to the controller (LEC), reset the data link after supplying power to the controller (LEC). (Refer to 12.4 Gateway unit control flag for the details of data link reset.)

Locking position 8 - Maintenance Caution DC> M12 Connector With light/surge voltage suppressor (WOZ) Connect correctly the lead wires to + (positive) and (negative) indications on the connector. Solenoid valve side pin wiring diagram 9 - 2.

The leakage current should be 5% or less (AC coil) or 2% or less (DC coil) of the rated voltage. 2. Use in low temperature environments Protection against freezing or solidification of impurities etc. When heating the valve body and piping by a heater, etc., be careful not to heat the coil with the heater. 4 Installation Warning 1.

When the wires are to be installed in the control panel along with those for other types of equipment, make sure to separate the AC and DC lines (to prevent the risk of damaging the elements in the circuit due to noise). Twisting the AC lines together is an effective countermeasure against noise. 5.