Lead wire length (mm) 300 600 1000 2000 3000 6 10 20 30 Plug connector lead wire length The lead wire length of the valve with lead wire is 300mm. When ordering a valve with lead wire of 600mm or more, order the valve without lead wire and order the lead wire separately.

L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31

Applicable bore size (mm) Flat type +0.048 0 +0.048 0 CJ-T010SUS 10 3.3 A D L MM N R W 4.5 29 18 3.1 2 9 40 22 32 12 Round type CJ-T016SUS 16 5 5.5 35 20 6.4 2.5 14 48 28 38 16 CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 CJ-CF016 CJ-CR016 16 10 12 15 M5 x 0.8 7 12 10 6

TECHNICAL DESCRIPTION 5.1 Control Panel 5.2 Operation 5.3 Flow diagram 5.4 Refrigerating Compressor 5.5 Condenser unit 5.6 Dehydration Filter 5.7 Capillary Tube 5.8 Evaporator 5.9 Hot Gas By-pass Solenoid Valve 5.10 Air Air Exchanger 5.11 Condensate Separator 5.12 DMC11 Air Dryer Controller 5.13 Electric Layout 6.

200VAC 5%oHz C-110V4C5%oHz tl 220VAC 6%oHr 5 24VDC 612VDC 9'OtherB ' Spcial ordr How To Order Pilot Valve sF4 50 _ _Non_tccking push type BSlotted locking type CKnob locking type t'100V C'%oHz t _ 2ou,,h$.oaoHz 3-t10vAcr%oHz a22O,D.C'%otta 5 2itVDC Gt2v0c I -Olher!

VR VH VHS Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.

, R2 port 31 31 : 3 position ( ): Rc3/8 1.11-6 Single Unit Series VQ4000 Base Mounted Plug Lead Grommet G H 2 position single: VQ415 l 0 1 155.5 155.5 105.5 42.5 23.5 23.5 50 105.5 42.5 50 11 (B port) 11 (A port) Indicator light (12.5) (12.5) SY 5 3 4 2 SYJ 9 38 48 A B 38 24.6 10.5 48 11 1 A SX 4 2 3 5 1 14 12 13.5 13.5 30 45 25.6 Mounting hole 30 45 VK Manual override 25.6 Mounting hole

(P2) () 3) 4) 5) 23 5 No.VEX-OMY0001 VEX3 3 / DC () 5 20N 1) 2) 1 ()ISO VG32 2 ISO VG32 ,(SDS) 6 No.VEX-OMY0001 VEX3 3 / () 30 ( ) , 1 VG32 2 ()ISO VG32 7 No.VEX-OMY0001 VEX3 VEX3 12,22,32,42 ,300mm DXT170-80-A1) 2) Lmm 2 300 6 600 1 (2 ) AC100V 10 1000 2 (2 ) AC200V 15 1500 3 (2 ) AC 20 2000 DC L 4 :+ :DC 25 2500 DXT170-71-1 30 3000 0.20.33mm ( 1.7mm) DC : M 3.23.7mm

ZSE6 ISE6 8 10 ZSE3 ISE3 l50 l45 l48 56 70 4.5 (MAX.8) 35.5 12.5 GS PS ISA 9 8 7 6 10 ZSE1 ISE1 17 10-M3 ZSE2 ISE2 11 23 6 38 50 ZSP 48 (54) ISl ZSM DIN rail L PFl 7.5 10 25 5 IFl 4.5 35 27 Material: Aluminum Part number of DIN rail Part number ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 L 105 140 175 210 245 280 315 3.1-14

Make sure to cycle valve at least once every 30 days. (1) (2) (6)(5) (4) (3) (7) (8) (9) (10) How to Calculate the Flow Rate Figure (1) (11) For obtaining the flow rate, refer to page 4-1-6. 4-9-3 4 Series VG342 Dimensions Grommet (G) (Lead wire length) Manual override (Non-locking) 300 Rc 1/8 (External pilot port) Rc 1/8 (Pilot exhaust) Switching plate (Mounting hole) Courtesy of Steven

Runoff space 2 mm or more Mounting bracket , Note) Use a watchmaker s screwdriver with a grip diameter of 5 to 6 mm to tighten the set screws (M2.5). The tightening torque should be 0.05 to 0.1 Nm. As a rule, it should be turned about 90 beyond the point at which tightening can be felt. Auto Switch Mounting Bracket Part No. Auto switch part no.

Connecting Female Thread: G Approx. spanner tightening angle after tightened by hand deg Standard torque (Nm) Nominal size of uni thread 1 8 1 4 3 8 1 2 30 to 45 15 to 30 15 to 30 15 to 30 3 to 4 4 to 5 8 to 9 14 to 15 2. Gasket can be recycled 6 to 10 times. It can be replaced easily when it has sustained damage.

TB W Counterbore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60 100

Parameter Default ( ) 6. 6. Clear Error Log -32No.EX-OML0010CN-C 4. Parameter Setting() 2. [4.Parameter Setting] Waring 1. 3. 4. 1. 34 2. 34 3. 35 4. 41 -33No.EX-OML0010CN-C 1. a) b) c) d) 2.

x 1 Piping port 2-M5 x 0.8 Cover side (rear side) 5 8 6 20 M5 x 0.8 20.3 25 23 14 2.3 9 6 33 21 0 -0.3 18.3 9.5 42 15 55.5 + Stroke 28 83.5 + Stroke 2-5.5 Mounting hole With rear end lock / CBJ2L16-HN Piping port 2-M5 x 0.8 6 8 8 Cover side (front side) 2-M10 x 1 5 20 M5 x 0.8 19.8 23 25 14 2.3 9 6 33 0 -0.3 18.3 12.5 12.5 15 42 28 8 50 + Stroke 86 + Stroke 2-5.5 Mounting hole 5 Series

Bit No. 6 4 6 4 2 0 0 0 Solenoid on side A 0 2 4 6 8 16 28 30 Output No. Internal terminating resistor is connected Side D Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

40 30 10 15 15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 4.5 4.5 6 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AMF550 AMF650 AMF850 1 2 1 2 1 2 1 AMF450SAME, #4 AMF550SAME, #5 AMF650SAME, #6 AMF850SAME, #7 4.6-32 Series AMF Precautions Dimensions: AMF801/901/800/900/1000 AMF801/901 Be sure to read before handling.