Piping: Base Mounted: Side Ported, Stations & Port Location: 18 Stations (Type 20, 41, 42, 43), A, B Port: NPTF1/8
Piping: Body Ported, Stations & Port Location: 18 Stations (Type 21, 41 and 42), Port Size: NPTF
Piping: Base Mounted, Stations & Port Location: 18 Stations (Type 21, 41 and 42), Port Size: NPTF1/8
Maximum acceleration: 3000mm/s2 Positioning distance (mm) 400 200 100 10 1 10 40.4 20.4 10.4 1.4 0.5 100 4.5 2.5 1.5 0.6 0.5 Speed (mm/s) 250 2.1 1.3 0.9 0.6 0.5 500 1.4 1.0 0.8 0.6 0.5 A B C D Values will vary slightly depending on the operating conditions. 163 18 Series LG1H21 Standard Motor High Rigidity Direct Acting Guide With Coupling Motor Output Rolled Ball Screw 100W 15mm /20mm
4] 1.2 [4.5] 1.3 [5] 0.7 [2.5] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Input/Output Characteristics: Flow Rate (Representative Value) Inlet pressure: 44 psi (0.3 MPa) Fluid: Water LVR20 LVR40 LVR50 12 [45] 26 [100] 1.1 [4] 24 [90] 11 [40] 0.9 [3.5] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] 21 [80] 9.2 [35] 0.8 [3] 18
Air consumption Note 3) 18 L/min (ANR) or less (SUP = 0.5 MPa) Note 1) Specification values are given at normal temperature (20C). Note 2) Characteristics relating to accuracy differ depending on combination with other constituent loop equipment, such as positioners and actuators. Note 3) Air consumption is due to exhaust from nozzle. And (ANR) indicates JIS B0120 standard air.
P362020-2 P362020-13 P362020-2 12 Diaphragm assembly NBR, other P362010-2 1 1 1 1 1 P362020-5 P362020-5 P362030-34 P362030-34 13 Diaphragm NBR, other 1 1 P36202019 P36202019 14 Valve Stainless steel, NBR P36201058 1 15 Valve Stainless steel, H-NBR 1 1 P36202068#1 P36202068#1 16 Valve Brass, NBR 1 1 P36203009#1 P36203009#1 17 Valve Brass, NBR 1 1 P36203010#1 P36203010#1 18
IZF21/31 Series Dimensions IZF21/31 IZF10/IZF10R Technical Data With automatic cleaning unit IZF21-m-mmSm IZF31-m-mmSm 64 (144) 20.5 (40) 64 (40) (104) 20.5 153 113.4 (195) (155) With adjustable louver IZF21-m-mmWm IZF31-m-mmWm (60) (144) 14 (40) 127 (60) (104) 14 (40) 89 127 89 (195) (155) With filter IZF21-m-mmmU IZF31-m-mmmU (144) (45) 134 5 (40) (45) (104) 5 (40) 95.5 126 87 (195) (155) 18
Internal mounting IZD IZE 20.5 2 x 3.4 33 IZH 30 30 52 46 44 26 17 11 40 5 8 x 3.4 20 26 12 2 x Hexagon socket head cap screw M3 x 6 (Accessory) Internal mounting Pivot mounting 21 33 (Mounting angle adjustable range) (90) 61 61 30 Pivoting bracket/IZN10-B2 20 3.4 56 64 28 20 (Mounting angle adjustablerange) 20 9.5 9 90 24 3.4 4 14 40 2 x Hexagon socket head cap screw M3 x 16 59 11 (Accessory) 18
Operate in an ambient humidity range between 45% to 80% (no condensation). 18 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Motor Controller JXCE1/91/P1/D1/L1 Series Dimensions JXCL1 35 4.5 For body mounting (Screw mounting) (11.5) 67 32.5 1.2 84.2 64.2 35 193.2 (When removing DIN rail) 187.3 (When locking DIN rail) 152.5 161 170 Mountable on DIN rail (35 mm) 77 17.5 4.5 For body mounting (Screw mounting) L 5.25 12.5 (Pitch) 7.5 5.5 (25) (35) 1.25 L Dimensions [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
End Plate Model EX245-EA2-1 EX245-EA2-2 Bracket Yes No Weight 200 g 150 g EX245-EA24 EX245 Series Dimensions SI Unit End Plate EX245-SPN1 EX245-EA2-1 120 6.5 14 22.1 28.6 6.6 5.6 98.8 148.5 133.5 61.5 1.6 6 85 10 EX245-EA2-2 37 18 120 14 61.5 44 50 130 23 35 Digital Input Module Digital Output Module EX245-DY1 EX245-DX1 22 22 27 13.5 61 120 120 81 27 54 54 61 5 Fieldbus System: For Input/
Material FGFC3-40 Carbon steel F-86S FN AL-79S AL-80S FGF3-40 FGFR3-40 FGFC3-40 159 115 3 10(4B) F-90S F-86S V#6500 210 175 115.4 19 18 FGF5-60 FGFS3-40 FGFR3-40 220 167 3 Stainless steel F-87S AL-79S AI-17S EB ES FGFL3-40 FGFS3-40 Note) 2 pieces are required per filter unit.
Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Connection Model Port size Rated flow rate Companion flange, Female threaded companion flange, L-block companion flange, L-block female threaded companion flange, S-block companion flange, S-block female threaded companion flange (L/min) FHG9A-M-04 FHG9A-M-06 FHG9A-M-08 FHG9B-M-10 FHG9B-M-12 FHG9B-M-16 FHG9C-M-20 FHG9C-M-24 1/2B 18
71.3 AR40(K)-06-B 3/4 1/8 75 93.2 35.8 33.8 M42 x 1.5 33.8 3 28 34.8 27.8 45.3 42.5 71.3 42.5 71.3 AR50(K)-B 3/4, 1 1/8 90 125.2 43 43.3 M62 x 1.5 43.3 3.2 28 44.3 27.8 54.8 42.5 80.8 42.5 80.8 AR60(K)-B 1 1/8 95 129.6 46 43.3 M62 x 1.5 43.3 3.2 28 44.3 27.8 54.8 42.5 80.8 42.5 80.8 Optional specifications Model Bracket mount Panel mount M N Q R S T U V W Y Z AR10-A 25 28 30 4.5 6.5 40 2 18
D2 Blue () COM 14-11-18 3 Digital Pressure Sensor Series GS40 Dimensions 14 10 F.R.L. Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type PT type 40 VBA VE SMC DIGITAL PRESSURE SENSOR ALM.
Tank capacity Approx. 110 mL Port size Rc1/4 Fluid contact material Stainless steel, EPDM, NBR, Ceramics, PPE, PPS, Carbon, PP , POM Power supply 24 VDC 10% Electrical system Power consumption 12.5 A (Peak current 18 A) Alarm Refer to Alarm.
-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A 142.1 174.1 176.1 247.1 261.1 93.9 122.1 154.1 156.1 227.1 241.1 91.4 28 30 35 34 47 47 2.3 2.3 2.3 2.3 3.2 3.2 40 53 70 70 90 90 8.4 13 12.5 12.5 13 13 5.4 6.5 8.5 8.5 11 11 22 23 26 25 35 35 27 35 52 52 66 66 30 41 50 50 70 70 20 26.7 35.5 35.5 45 47.5 25 35 40 40 30 30 30 38.4 38.4 20 26.7 35.5 35.5 45 47.5 9.8 14 18
Stations L1 L2 2 stations 33.5 27.5 11 128 122 12 138.5 132.5 13 149 143 14 159.5 153.5 15 170 164 16 180.5 174.5 17 191 185 18 201.5 195.5 19 212 206 20 stations 222.5 216.5 3 44 38 4 54.5 48.5 5 65 59 6 75.5 69.5 7 86 80 8 96.5 90.5 9 107 101 10 117.5 111.5 645 Series 10-V100 Specific Product Precautions 1 Be sure to read before handling.
Otherwise, unexpected malfunctions, such as knocking, may occur. 18. In the case of the belt drive actuator, vibration may occur during operation at speeds within the actuator specifications, this could be caused by the operating conditions. Change the speed setting to a speed that does not cause vibration.