Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Port Size: N01 (1/8 NPT), Applicable Tube OD: 09 (5/16"), Sealant: S (Sealant)
Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 1 (Meter-in), Port Size: N01 (1/8 NPT), Applicable Tube OD: 09 (5/16"), Sealant: S (Sealant)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-89 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)
This is a legacy product, and replaced byZH07DSA-07-N01-07, VACUUM EJECTOR, 1/4 SUP, VACUUM SERIES, ZH VACUUM EJECTOR, BF, ZH NOZZLE SIZE 0.7, .04620 lb
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-89 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 07 (One-touch Fitting ø1/4"), VAC: N01 (Screw-in NPT 1/8), EXH: 07 (One-touch Fitting ø1/4"), Accessories: NS (w/o Standard Bracket, w/Silencer)
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 07 (One-touch Fitting ø1/4"), VAC: N01 (Screw-in NPT 1/8), EXH: 07 (One-touch Fitting ø1/4")
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: S (-90 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: N01 (Screw-in NPT 1/8), EXH: 07 (One-touch Fitting ø1/4"), Accessories: S (w/Standard Bracket, w/Silencer)
F-Parameter (According to PROFIsafe system description, Version 09, November 2007) F-Parameters contain information for adapting the PROFIsafe layer to customer specifications and for checking the parameterization by means of a separate method (diverse).
OUT2 output mode / output style 17 Line name (left side 4 digits, right side 5 digits) 18 Display channel 19 CH1 measurement display value 20 CH2 measurement display value 21 CH3 measurement display value 22 CH4 measurement display value 23 Display OFF (No display) : Settable : Not settable (negative acknowledge) -94No.PS-OMW0012-C Value (16 Hex number) 00 01 02 03 04 05 06 07
08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -88No.PF-OMZ0002-A Troubleshooting If an operation failure of the product
08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure of the product
08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles from the following
08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -49No.PF-OMX0007-A Specifications Models PF3A701H PF3A702H Applicable fluid 1 Air, N2 Fluid Operating fluid temperature 0 to 50 oC Detection
08 09 0A 0B 0C 0D 0E 0F 7seg Display letter 11seg Value (16 Hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7seg Display letter 11seg Value (16 Hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 7seg Display letter 11seg Supplementary information : Do not work [Toggle output command] Value Item Remarks CH1 0 1 CH2 Measurement value 2 CH3 3 CH4 CH1_OUT1 16 17 CH1_OUT2
08 09 13 * Stopper nut must be ordered as a separate item.
Inch size Metric size Port size 4 04 03 5/32 M5 M5 x 0.8 Thread type 6 06 07 1/4 U10/32 10-32 UNF 8 08 09 5/16 Metric thread (M5) 01 1/8 Nil 10 10 11 3/8 Unified thread (10-32 UNF) 02 1/4 12 12 13 1/2 R 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tubing O.D./Port Size Combinations From male thread to One-touch fitting A Metric size Inch size Applicable tubing O.D.
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.