SMC Corporation of America
Elite Part Number Search
Search Results "Y54-06-1-D"

2 1/8, 1/4 Note 1) The system accuracy when combined with PF2A3.

regulator IN port SRF Booster regulator IN port C C ITV EXH: C EXH: C IC (A) (B) Tank OUT port Rc 3/4 (A) D (B) OUT OUT 355 ITVH 256 256 205 4 x 13 4 x 13 ITVX 50 50 150 150 500 PVQ 250 250 824 (mm) VY1 Drain port Rc 1/4 A 531 570 494 527 576 B 444 479.8 444 479.8 479.8 C Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 1/2 D Note) 519 543 Booster regulator model VBA20A VBA40A VBA22A VBA42A VBA43A VBA

4 1 2 1 2 4 6 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Thread type Nil N F Rc NPT G AK4000-03/-04 AK6000-06/-10 Port size 0.5 MPa 0.5 MPa Port size Applicable series AK2000 AK2000/4000 AK4000 AK4000 AK6000 AK6000 Inlet pressure: 0.1 MPa Inlet pressure: 0.1 MPa 0.3 MPa 0.3 MPa 0.7 MPa 0.7 MPa 01 02 03 04 06 10 1 8 1 4 3 8 1 2 3 4 1 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 15-

Note 1) (A) 4 (B) 2 0 1 Metal seal Rubber seal 3 Note 2) D: Slide locking type (Manual) 5 (R1) 3 (R2) 1 (P) When specifying more than one option, enter symbols in alphabetical order. Note 1) For metal seal type only.

AS1001F (3.2, 4, 6, 1/8", 5/32", 1/4"), AS2001F (4, 6, 5/32") are POM. In-line Type Applicable tubing O.D. d Inch Size Metric Size Applicable tubing O.D. d Applicable tubing O.D. d Model Weight D1 D2 L1 L2 M1 L3 Max. Min. (g) Model Weight D1 D2 L1 L2 M1 L3 Max. Min.

Fig.1-3 shows the location of the communication port. 14 1 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 Fig.1-3 Communication port HRS400-A-46 1.3 Communication port 1-5 DOC1003626 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.

mm2 39.5 7.8 42.5 P R 1 3 15 8 2-M5 x 0.8 PE port 13.4 2-Rc 1/8 Port 3(R) 16.3 41.2 2-Rc 1/8 1(P) port 46.5 The broken lines indicate the DIN rail mounting style [-D].

SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT (mm) A One-touch fitting d Part No.

Symbol -X80, -X81 Main Value Double Acting Type 1 A N 06 5 1 4 VP31 1 D Z X81 Body size CE marking Nil Q None CE-compliant 4 6 8 1/2 1 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 2 Port size (IN, OUT port) Thread type Symbol VP3145 VP3165 VP3185 Port size Nil F N T D/DO/DZ/DU only Rc G NPT NPTF 03 04 06 10 12 14 20 Type of actuation X80 X81 Double solenoid Single solenoid External pilot Passage, Type

ZFC100-06 ZFC200-06 Replacement Parts ZFC200-08 0.1 1 10 100 Description Part no.

Fig.1-3 shows the location of the communication port. 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 1 14 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 Fig.1-3 Communication port 1.3 Communication port HRL Series 1-4 HRX-OM-W069 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.

diagram VK VK Surge voltage supressor (Built-in terminal) LED VT R D LED R R NL Markings For AC, 12 VDC or less For 24 VDC or more + 1 2 1 2 1 2 NL: Neon light R: Resister LED: Emitting diode R: Resister D: Protective diode LED: Emitting diode R: Resister 1429

VQZ (A) 2 (A) 2 VZ 3 (R) 1 (P) 3 (R) 1 (P) VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts No.

Series None DIN rail mounting (DIN rail standard length) DIN rail mounting (Without DIN rail) 1 VQZ100 VT D DO (1) VT Note 1) Order DIN rail separately.

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

VV5K3-20-06 VV5K3-40-06-M5 Common SUP/Common EXH VK Type 20: Body ported (A, B port top ported) Applicable solenoid valve VK3120M5 VK312001 VK332M5 VK33201 How to Order A port: Rc 1/8, M5 x 0.8 VZ VV5K3 20 05 A, B port Rc 1/8, M5 x 0.8 VK3120 Thread type VF VK332 Valve stations Nil 00F 00N 00T Rc 01 1 station Applicable blanking plate assembly VK3000-7-1A VFR G NPT 20 20 stations R port:

DIN terminal: VP3185-D Conduit terminal: VP3185-T A B A B VQZ VZ Conduit terminal with indicator light (TL) G 1/2 Max. 11 Applicable cable 6 to 12 VS Light Light VFN Rc 1/4 G 1/2 Rc 1/4 ( ): With indicator light (TL) 4-10-7 8 Made to Order Specifications: Series VP3145/3165/3185 Main Valve Double Acting Type: -X80/X81 How to Order 1 D Z A N X 06 5 1 4 VP31 81 80 Type of actuation Body size

sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Symbol Base mounted 2 1 8 1 4 Internal pilot VY1D0 (5) Without sub-plate 1 4 4 3 8 1 2 A (3) (3) M5 3(R) 1 8 2(A) 1(P) 1 (3) (3) 1 4 1 4 3 3 8 External pilot 1 2 Body ported 1 2 5 3 4 P1 1 1 VY1B0 (5) 7 1 1 4 1 3(R) 1 4 1 1 2 2(A) 1(P) 9 2 2 Note 3) Only bracket or foot may be mounted.

304 Splashproof/Low jetproof type (Equivalent to IP44) 2 Port size 10 06 3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.

Accessory (Option) Basic size (Applicable compressor kW) F With screw flange D With auto-drain Port size Symbol 2 Screw type Reciprocating type 2.2 7.5 15 22 37 55 75 04 06 14 20 30 Rc 1 2 Rc 3 4 Rc 1 1 2 Rc 2 3B flange HAW2 HAW7 HAW22/37 HAW55/75 HAW110 Caution on Design 7 22 22 Warning 1.