) 2) 1) 14 to 194F (10 to 90C) for Vespel and PEEK seat.
ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).
ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).
*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.
Z\Warning 1.Do not drop or cause impact to $witch. Do not drop, apply excessive impact (more than 300m/s2 for reed switch, more than 1000m/s2 for solid-state switch) when handling. Damage could occur to the inside as well as the body. 2.Do not pull the lead wire wiih excessive force. Do not pull the lead wile to move the cylinder.
Pressure Do not use it in the vacuum state, which is substantially different from the atmospheric pressure (above sea level) and in the atmosphere under being pressurized. 10-18-14 13 Shock Absorber: Short Type Series RBQ Precautions Be sure to read before handling. Refer to pages 10-24-3 to 10-24-6 for Safety Instructions and Actuator Precautions. Mounting Maintenance Caution 3.
Description Material 25 32 40 NBR Rod seal HDU-8 HDU-10 HDU-12L HDU-14 !
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
Approx. 5.6k Switch DICOM 24VDC 10% 150mA Approx. 5mA VCES 1.0V ICEO 100 A (2) Digital output interface DO-1 A maximum of 2.6V voltage drop occurs in the driver. If polarity of diode is reversed, servo amplifier will fail. Servo amplifier Driver driver ALM, etc. Load DOCOM (Note) 24VDC 10% 150mA Note.
Do not apply excessive rotational force to the display unit. The integrated type display unit can rotate 90. If more rotation is required, a separate display unit is available as special order. 4. Be certain to turn on the power when the flow rate is at zero. Allow an interval of 10 minutes after turning on the power, as there are some changes in the display. 5.
Bore size B DA DB DL DU DC DX DE DO DR DT DS DH Z DD H10 32 219 40 237 50 268 63 280 80 351 100 371 MB-B03 32 46 42 32 22 10 44 14 62 9 6.6 15 7 33 213 10+0.058 0 40 52 42 32 22 10 44 14 62 9 6.6 15 7 33 231 10+0.058 0 MB-B05 50 65 53 43 30 11.5 60 20 81 10.5 9 18 8 45 260 14+0.070 0 63 75 53 43 30 11.5 60 20 81 10.5 9 18 8 45 272 14+0.070 0 MB-B08 80 95 73 64 45 14 86 30 111 12.5 11 22 10
D-Y69A/Y69B/Y7PV* D-Y7G/Y7H D-M5N/M5P/M5B D-S991/S992/S99V1/S99V2 D-S9P1/S9P2/S9PV1/S9PV2 D-T991/T992/T99V1/T99V2 D-S791/S792 D-T791/T792 D-S7P1/S7P2 D-T791C/T792C 10-20-27 Grommet 10-20-28 Connector 10-20-29 Band 10-20-30 Terminal conduit 10-20-31 10-20-32 Grommet 10-20-33 Rail 10-20-34 Connector 10-20-35 Grommet Tie-rod 10-20-36 Terminal conduit 10-20-37 10-20-40 10-20-38 10-20-41 Grommet
-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum switch unit E C ZX1 1 10 Ejector unit Filter unit F ZX1 1 10 Ejector unit PV/V port size Ejector unit nozzle dia.
Do not abruptly reduce the size of the pipe anywhere in the piping lines. The pressure distribution in the piping will change, and accurate measurement will become impossible. [When used for water] 10. Never mount a switch in a place that will be used as a scaffold during piping work. Damage may occur if subjected to an excessive load.
Do not apply excessive lateral load to the piston rod.
10.5 20 9.5 6 10 35.5 72 19 17.5 CY1R10 9 38 3.5 4 M3 x 0.5 4.5 M5 x 0.8 68 14 14 20 13 8 15 39.5 76 26 17.5 CY1R50 25 110 8.6 10 M8 x 1.25 15 Rc 1/4 159 48 42 60 41 10 50 113 176 82 30 CY1R63 24 118 8.6 10 M8 x 1.25 16 Rc 1/4 171 60 48 70 47 10 60 121 188 94 32 8-15-42 42 Series CY1R Magnetically Coupled Rodless Cylinder Direct Mount Type Centralized Piping Type: 10, 50, 63 CY1RG Bore size
Metric System (g) = 105.5 meters per sec. per sec NewtonMeters KilopondMeters Foot-lbs Inch-lbs 3 3 1.020 x 10 -1 7.376 x 10 -1 8.851 1 3 7.233 3 3 1 3 86.80 0.01 3 1.382 x 10 -1 1 3 12 3 1.356 1.130 x 10 -1 1.52 x 10 -2 8.333 x 10 -2 1 3 Length (Linear Measurement) Meter Centimeter Kilometer Mile Inch Foot 3 100 3 1x10 4 6.214x10 -4 39.370 3 3.281 3 1 3 1 3 1x10 5 6.214x10 -6 3.937x10 -1
Metric System (g) = 105.5 meters per sec. per sec NewtonMeters KilopondMeters Foot-lbs Inch-lbs 3 3 1.020 x 10 -1 7.376 x 10 -1 8.851 1 3 7.233 3 3 1 3 86.80 0.01 3 1.382 x 10 -1 1 3 12 3 1.356 1.130 x 10 -1 1.52 x 10 -2 8.333 x 10 -2 1 3 Length (Linear Measurement) Meter Centimeter Kilometer Mile Inch Foot 3 100 3 1x10 4 6.214x10 -4 39.370 3 3.281 3 1 3 1 3 1x10 5 6.214x10 -6 3.937x10 -1
: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.