DIN connector (Without connector) 04 1 2 1 2 AN 04 5 06 1 2 3 4 1 2 3 4 1 Body ported G Grommet (300mm lead wire) AMC 10 1 1 1 H Grommet (600mm lead wire) E Grommet terminal 10 7 12 14 9 20 2 Wihout subplate 1 4 1 T Conduit terminal D DIN connector 1 4 1 2 1 2 G Grommet (300mm lead wire) Grommet (600mm lead wire) DIN connector DIN connector(Without connector) 2 01 1 8 1 8 H D DO Base mounted
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid
Do not use the product at a high frequency. Use it at 30 cpm or less as a guideline. 4. Do not wipe out the grease in the sliding part of the air cylinder. Doing so forcefully may cause malfunction. 1. The piping length between the speed controller and the cylinder port must be kept as short as possible.
Do not use in atmospheres of corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these. 2. Do not use in direct sunlight. 3. In locations near heat sources, protect against radiated heat. 4. Do not use in locations where static electric charges will be a problem. Consult with SMC regarding use in this kind of environment. 5.
The received message is deleted if the calculation result and received LRC do not match. Consecutive 8 bits of the message are added, and the result without carry (overflow) is converted to 2's complement.
Do not use liquids that will cause the wetted sealant to swell.
Conduit terminal: VP3185-T A B DIN terminal: VP3185-D A B Conduit terminal with indicator light (TL) Light Light position Max. 11 Applicable cable 6 to 12 [ ]: With indicator light (TL) 1500 Made to Order: Series VP3145/3165/3185 Main Valve Double Acting Type: -X80/X81 How to Order 1 D Z A N X 06 5 1 4 VP31 81 CE-compliant Body size CE-compliant Nil 4 6 8 1 2 Q Electrical entry: D/DO only
/521 20A (Port size 06) 40A (Port size 14) p16 p10 PF3W711/511-;06 p9 p8 p7 p6 p5 p4 p3 p2 p1 p0 p14 (at 100 L /min) p12 Accuracy [% F.S.]
Place an order for the cable assembly separately. kit (D-sub connector) 15 pins F kit (Flat ribbon cable) 10/16/20 pins P How to Order Manifold How to Order Manifold 06 C6 F SA VV5Q11 06 VV5Q11 C6 P SC Option Option Stations Stations Cylinder port Cylinder port How to Order How to Order D-sub connector, 15 pins Connector locationSide Without cable Flat ribbon cable, 20 pins Connector locationSide
Do not install any back pressure check valve on the manifold station, on which the spacer is to be mounted.
Refer to each construction drawing on the fittings and tubing material. (2) Do not expose the product to direct sunlight for an extended period of time. (3) Do not use in a place subject to heavy vibration and/or shock. (4) Do not mount the product in locations where it is exposed to radiant heat. (5) Do not use the ordinary fittings and tubing in locations where static electricity would
Dimensions q Do not use the air cylinder as an air-hydro cylinder. This will cause an oil leak. w Install without twisting the bellows. If the cylinder is installed with its bellows twisted, it could damage the bellows. Rubber bumper Disassembly/Replacement Caution q Do not replace the bushings or the cushion seals. The bushings and the cushion seals are press-fit.
Do not remove the panels except for the cases permitted in this manual. Do not remove the panels during operation. Use assistance to carry object over 20 kg.
Do not apply heat cycle.) Operating fluid temperature 0 to 100C (Not be frozen. Do not apply heat cycle.)
Operating environment Do not allow corrosive fluids or solvents, etc., to come into contact with the outer surfaces of the pump. Do not use in water (or other liquid). Fluid may leak into the pilot switching valve and there may be corrosion of external parts, etc. 2. Low temperature operation Do not allow freezing.
Therefore, do not use it with or expose it to the following chemicals: paint thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, water-soluble cutting oil (alkalinic), etc. 2. Do not expose it to direct sunlight.
Therefore, do not use with or expose it to the following chemicals: paint thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, watersoluble cutting oil (alkalinic), etc. 2) Do not expose it to direct sunlight.
DC DO DL DU DU DE Rotating Angle DA Ao Bore size (mm) Ao Bo Ao + Bo + 90o 40 to 100 12o 60o 162o (mm) DDH10 (Hole) Bore size DA DL DU DC DX DE DO DR DT DS DH DF B Z Part no.
VV5ZS2 C6 06 51G 1 VFN Thread type Series VZS2000 Manifold Standard Nil NPT Rc N T F Plug-in type Stacking type manifold base with attachment plug lead wire NPTF G Option Port size Rc 1 8 01 Embedded type One-touch fitting Applicable tubing O.D.: 4 Stations C4 02 2 stations C6 Embedded type One-touch fitting Applicable tubing O.D.: 6 15 stations 15 Symbol Max. 15 stations.
X Port size) Silencer System Solenoid valve Speed controller VFS 4 X 1/8 AS2301F01-04 A VS SYJ5l40-01 Rc(PT)1/8 (S = 4.5mm2) AS2301F01-06 B VS7 AN110-01 (S = 35mm2) Plate fixing screw 6 X 1/8 AS3301F -06 02 03 C 8 X 1/8 AS3301F -08 02 03 D Note) Do not loosen plate fixing screw. 1.2-31 Series SYJ5000 How to Order Light and surge voltage suppressor For electrical entry G,H,L and M Configuration