Do not separate the cylinder from the valve. 2. Do not disassemble or modify the guide rod. 3. This product should not be used as a stopper. Cushion Rubber bumper Stroke length tolerance dose not include the amount of bumper change.
Do not apply negative pressure. It may result in malfunction. Should they remain, they could cause malfunction. 3. When connecting pipes and fittings, etc., be sure 3. Do not supply air pressure from ports other than that neither chips from the pipe threads nor sealing material get inside the valve.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2018 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printing WY 9520KS Printed in Japan. D-G
Do not use in a location having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. Do not use in locations where radiated heat will be received from nearby heat sources. Maintenance Warning 1. Maintenance should be performed in accordance with the procedures in the Operation Manual.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2018 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing VQ printing WQ 10270SZ Printed in Japan. D-G
Connection Be sure that chips from the pipe threads and sealing material do not get inside the piping. Further, when sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of male threads. Do not use with gases. 4.
PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.
Do not use in locations where static electric charges will be a problem. Please consult with SMC regarding use in this kind of environment. 2. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. 3. Do not use in environments where there is direct contact with liquids such as cutting oil, lubricating oil or coolant oil, etc.
Do not disassemble the product. Once the product is disassembled and reassembled, it will not be able to satisfy the original performance. 4. When piping, do not get the pad side and vacuum generator side of the product the wrong way round. (Refer to Fig. 1.)
CJ1 q Do not apply more than the allowable rotating torque to the piston rod. If more than the allowable rotating torque is applied, the non-rotating guide will be deformed and there will be a significant loss of rotational accuracy. This may cause damage to the machinery.
Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with same. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. 4. A protective cover, etc. should be used to shield valves from direct sunlight. 5.
The load ratio is obtained by the following formula: ((Load mass x 9.8)/Theoretical output) x 100% Conditions MB, CA2 series CS1, CS2 series Series Condition 10A x 1 m SGP (Steel pipe) dia. x Length VQ4100--03 VQ4101--03 AS420-03 Speed controller AN30-03 Silencer 10A x 1 m SGP (Steel pipe) dia. x Length VQ5100--04 VQ5101--04 AS420-04 Speed controller AN40-04 Silencer 448 INDEX Page 446 Base
1/2 72 62 40 62 Y52-03 3/8 14 24 41 Y61-03 3/8 15 30 50.5 Y61-04 1/2 15 30 50.5 Courtesy of Steven Engineering, Inc. !
-01 KDM20S-03 KDM20S-07 KDM20P-01 20 KDM20P-03 KDM20P-07 KDM20S-09 KDM20P-09 Clamp bolt Panel mounting Loosen (4) screws for bracket on the socket side using a Phillips screwdriver (JIS nominal No. 2) until the bracket touches the stop ring.
Do not use these for pneumatic operations because they will lead to oil leaks. Air-hydro cylinder: CA1HCQ2HCS1HCM2HCG1H(up to 63) HC03-X1x Air-hydro rotary actuator: CRA1H2.
Do not use these for pneumatic operations because they will lead to oil leaks. Air-hydro cylinder: CA1HCQ2HCS1HCM2HCG1H(up to 63) HC03-X1x Air-hydro rotary actuator: CRA1H2.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 https://www.smcworld.com 2022 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-G
Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12
Do not use in lines where a pressurized condition is maintained, as the body may be damaged. Warning Caution 1. Tubing attachment/detachment for One-touch fittings 1) Installing the tubing (1) Use tubing with no flaws on its periphery and cut it off at a right angle. When cutting the tubing, use a tube cutter, TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc.
Do not grip the piping port on the back side or the handles of the panel. 3. Do not pass over bumps, etc., with the casters.