Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Handle/Bonnet Material: B (Aluminum), Options: BS (w/Bracket + Built-in Silencer, EXH Port)
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Handle/Bonnet Material: B (Aluminum), Options: BS (w/Bracket + Built-in Silencer, EXH Port)
Body Size: 40, Thread: Rc, Port Size: 06 (3/4), Handle/Bonnet Material: A (Flame Resistant PBT), Options: BS (w/Bracket + Built-in Silencer, EXH Port)
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Handle/Bonnet Material: A (Flame Resistant PBT), Options: BS (w/Bracket + Built-in Silencer, EXH Port)
Model no. 1 3 5 A VZ X1 ( ) VZ3 A ( ) Manual override Entry is the same as standard products. Entry is the same as standard products.
, z + A = 100 y, z + A a 100 10 y, z + A = 200 y, z + A = 200 y, z + A = 300 y, z + A = 300 1 1 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 800 Stroke [mm] Stroke [mm] [Graph 6] Allowable load mass by stroke 32 [Graph 5] Allowable load mass by stroke 25 100 100 y, z + A = 0 y, z + A = 0 y, z + A = 50 y, z + A = 50 10 Load mass [kg] Load mass [kg] 10 y, z + A = 100 y, z + A =
Z m1 x g x Y m2 x g x Y M2 y z z m4 x g x Y m3 x g x X Y M3 m4 x g g: Gravitational acceleration Dynamic Moment z Mounting orientation Horizontal Ceiling Wall Vertical M1 x a x mn x g 1.4 100 Dynamic load FE 1 3 Dynamic moment a x FE x Z M1E a Dynamic moment M2E is not generated.
BS Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
Z (Example) A80CZ None . N (Example) A80CN Note 2) Solid state auto switches marked with a "" are produced upon receipt of order.
Adjustable Hydraulic Series I Accessories lmperial FooT MOUNT (FtVt) Typical Foot Mount Installation OEIV] oEt\4 z/+, OEM LtE, 1.5M and OEM 2.0lvl FB FA OEM 1.15 -+ OEIVI 1.25 oEt\4 3.0tvl oEtvl 4.oM @^ -oFc FJ Notes: 1. OE[,] 1:]6x6, Z dimension is 2.69 in. 2. OEIV 2.0t\rx6, Z dimension is 2.69 in. 3. OEIV 3.0Mx6.5, Z dlmnsion ls 3.06 in. 4.
UP/DOWN X1 X2 X4 X4 4 SEL. UP DOWN SEL. (4) FUNC. FUNC. 1 LEFT/RIGH UP/DOWN SEL. SEL. (5) FUNC. FUNC. LEFT/RIGH SET SEL. SET FUNC. FUNC. FUNC. FUNC. -2 SEL. UP LEFT/RIGH OFFSET SEL. UP/DOWN SET SEL. 17 - DOWN -3 FUNC. FUNC. FUNC. FUNC. SEL. LEFT/RIGH STOP SEL. UP/DOWN UP 0.1 SET SEL. DOWN -4 FUNC. FUNC. FUNC. FUNC. SEL. UP/DOWN SET SEL. OUTPUT SEL.
resistance Impact resistance 147 m/s2 is given 3 times for each direction X, Y and Z Operating environment No corrosive gas -12No.EX##-OMU0020-A 3.
Model no. 1 3 5 A VZ X1 ( ) VZ3 A ( ) Manual override Entry is the same as standard products. Entry is the same as standard products.
A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Metal) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Rubber) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 3-position Closed center (FHG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Exhaust center (FJG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Pressure center (FIG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 6 Series VS R8 Rubber Seal S HOW TO ORDER VALVE VS R 8 6 FG S 3EZ V1 A03T X1
Model no. 1 3 5 A VZ X1 ( ) VZ3 A ( ) Manual override Entry is the same as standard products. Entry is the same as standard products.
(Default setting) 8 7 Configuration Mode Address X1 9 6 x10 x1 2 1 0 0 5 Mark C on the unit Mark B at cable end Mark A at cable end 4 Address 1 9 4 3 1 0 : : (1) 2 3 Input data + System diagnosis + Unit diagnosis (Up to 10 units) Input data + System diagnosis Input data only (Default setting) 8 7 9 6 6 Content 3 4 1 2 0 5 Content 5 0 (Default setting) 4 1 2 3 Node Address Data Rate 8 7 PGM
PWR for 2 hours each in direction X, Y and Z respectively (De-energized) Displays the data link status. Displays the status of the power supply voltage for outputs. Displays the status of the power supply voltage for control and input.
Tact time Moving distance: _mm t = Tact time: _s s = Cycle time: _s Time t s z x Example) Projection distance x: _mm y: _mm z: _mm Work piece moment y Environment General, Clean room, Mist environment, Dusty environment 94 23 Series LTF Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Positioning complete signal 19 OZ+ Z Z 10 20 COIN OZ+ 14 GND VDC 12 to 24V 13 4.7k COM Torque monitor: Zout 4.7k 12 + IM VDD 30V max. 15mA max. 11 Speed monitor: Zout 4.7k 4.7k SP + 21 CZ Z (Pin 14 is GND.) 26 FG CN I/F 205 Non-standard Motor Compatible Drivers Mitsubishi Electric Corporation Drivers for LJ1, LG1, LX Dimensions (RS-232C without optional unit) Driver 5 100 40 1-5 hole 5
With shock absorber (1 pc. on port side) TN TF 20, 25, 32 BS The adjusting bolt is installed even when B or BS is selected.(Except 10) Standard stroke (mm) Refer to Standard Stroke on page 1529.