i s p l a y a n d SigmaWin+TM 2.
Body Brass Body Hydrolic Oil Non-Flammable NR NR NR NR Standard R R R R Hydrochloric Acid NR NR NR NR Hydrogen R R R R # Inert Gases R R R R JP4 JET Fuel V V V V JP5 JET Fuel V V V V Kerosene R R R R Ketones PP NR PP NR Lacquer PP PP PP PP Linseed Oil R R R R Lubrication R R R R Mercury R*** NR R*** NR Natural Gas R R R R Nitric Acid PP NR PP NR Nitrogen R R R R Oxalic Acid NR NR NR NR Oxygen
Body Brass Body Hydrolic Oil Non-Flammable NR NR NR NR Standard R R R R Hydrochloric Acid NR NR NR NR Hydrogen R R R R # Inert Gases R R R R JP4 JET Fuel V V V V JP5 JET Fuel V V V V Kerosene R R R R Ketones PP NR PP NR Lacquer PP PP PP PP Linseed Oil R R R R Lubrication R R R R Mercury R*** NR R*** NR Natural Gas R R R R Nitric Acid PP NR PP NR Nitrogen R R R R Oxalic Acid NR NR NR NR Oxygen
clearance hole / NC(D)Q8N(Z)S T (Inch) Symbol Bore E 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.20 0.25 0.25 0.34 0.34 0.41 43 Series NCQ8 Dimension Both ends tapped NC(D)Q8A-(C)(M) NC(D)Q8WA-(C)(M) NC(D)Q8A-S(M) NC(D)Q8A-T(M) Both Ends Tapped (Inch) O1 R Bore size Remarks R R O1-Thread 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2")
Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.
Applicable cable O.D.: 4 to 6.5 (Reference) 0.5 mm2 2 core and 3 core wires equivalent to JIS C 3306 NL: Neon bulb R: Resistor LED: Light emitting diode R: Resistor D: Protective diode LED: Light emitting diode R: Resistor How to Calculate the Flow Rate For obtaining the flow rate, refer to front matters 44 to 47.
Q8W Both ends tapped NC(D)Q8WA-(C)(M) Symbol Bore O1 R R R O1-Thread 056(9/16") 075(3/4") 106(1 1/16") 150(1 1/2") 200(2") 250(2 1/2") 300(3") 400(4") #4-40UNC 0.34 #6-32UNC 0.34 #6-32UNC 0.50 #10-24UNC 0.50 #10-24UNC 0.53 1/4-20UNC 0.65 1/4-20UNC 0.69 5/16-18UNC 0.84 Note) Fully threaded tap for 012 stroke Screw clearance hole front mount/NC(D)Q8WE 4-E Symbol Bore E B 056(9/16") 075(3/4"
NPT thread Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32 1/4 5/16 3/8 1/2 From One-touch fitting to male thread B Bushing type AKB 01 A 01 S With seal (Standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction Female/Male
Metric Inch Model Port size 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 X 0.8 R(PT)1/8 R(PT)1/4 R(PT)1/4 R(PT)3/8 R(PT)1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT1/2 Specifications Proof pressure 1.5MPa Max. operating pressure 1MPa JIS symbol
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Description IR1000 IR3000 IR3020/3120 IR2020/2120 IR3010 IR1020 IR2000 IR2010 IR1010 Bracket Pressure gauge P36203018 P36202028 P36201023 G43-2-01 G43-4-01 G43-10-01 G43-4-01 G43-10-01 G33-4-01 G33-10-01 G43-2-01 G33-2-01 Accuracy 3% (Full span) 14-5-7 7 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 q i o !4 q o i !
ZS-35-C X X X X X E ZS-35-D X X ZS-35-F X X X X X + F ZS-35-G X X 1/ 1 ZS-24-A A M35 L,M45 L 2 ZS-24-B B M45 L, 2 ZS-24-D D M35 L,M45 L 2 ZS-35-C (01,N01) ZS-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A D D N NPN1
Supply port location 01 Nil Common exhaust Individual exhaust 1 Thread type C 1 8 Nil Rc 08 8 F G T NPTF (6) Digital vacuum switch unit Left side Right side R L B 21 C 0X ZSE3 D (3) Ejector assembly Both sides Unit for replacement 05 1 D W ZX1 Output specifications Unit for replacement Nozzle diameter Ejector exhaust 2 outputs/without analog output 2 outputs/with analog output 1 output
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-17 Connection of RS-232C HRSH Series 3.3Installation 3-25 HRX-OM-R026 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Light/Surge voltage suppressor Electrical entry (2) Manifold base (5) Digital vacuum switch unit 06 ZZX1 R B 21 C 0X ZSE3 D Supply port location Stations 01 1 Unit for replacement Thread type R L Left side Right side Nil F G Rc 1 8 Piping specifications 08 8 B Both sides C Connector (0.6 m) T NPTF Pressure indication System for external vacuum (3) Adsorption confirmation switch unit Output
port B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) 00 M5 00 M5 01 00 01 02 00 02 03 04 Symbol Mounting Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Base mounted 1 8 1 4 2 Without sub-plate 1 4 3 8 1 2 4 JIS Symbol Note) A M5 01 02 02 03 04 04 06 10 10 12 14 20 Note) M5 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 Note) Note) 3 Body ported 5 1 1 11 4 7 1 4 11 2 1 2 2 9 Note)
VQ1000-FPG-C4M5-D: 6 sets Double check block 757 S0700 Series Construction Body Ported Construction 2(B) (A)4 S0716 2-Position Single r u e w q 3(R2) (R1)5 1 (P) t y i 2-Position Double S0726 2(B) (A)4 r u e w q 3(R2) (R1)5 1 (P) t y i 3-Position Closed Center S0736 r u e w q 2(B) (A)4 (R1)5 1 (P) 3(R2) t y i 4-Position Dual 3-Port Valve S07A6 r u e w q 2(B) 4(A) 5(R1) 3(R2) 1(P) N.C. + N.C