Dimensions Foot style: MQMLL 6 25 14 33 42 18.5 2.3 6 9 2-5.5 66 + Stroke 75 + Stroke 93.5 + Stroke RE A B REC 10, 16, 20, 25 CX CY LY LH MQQ M X X Y Y LX LZ Z 4-LC S + Stroke LS + Stroke ZZ + Stroke LT RHC MK(2) RS Q G RS H A Bore size (mm) LC LH LS LT LX LY Z ZZ X S LZ Y RZQ 10 5.5 14 83 2.3 33 25 19 108 6 65 42 9 16 5.5 18 92 2.3 42 30 21 119 6 74 54 9 MI W S 20 6.8 25 137.5 3.2 40 40

MGP Auto switch model 20 25 32 40 1000 Holding force (N) D-B5, B6 D-G5, K5 D-C7, C8 D-H7 MGQ BA-01 BA-02 BA-32 BA-04 40 BMA2-020 BMA2-025 BMA2-032 BMA2-040 MGG 500 32 25 Stainless steel mounting bolt set The set of stainless steel mounting screws described below is available and can be used depending on the operating environment.

Dimensions Foot type/MQMLL 6 25 14 33 42 18.5 6 9 2.3 2-5.5 66 + Stroke 75 + Stroke 93.5 + Stroke 10, 16, 20, 25 LY LH X X Y Y 4-LC S + Stroke LS + Stroke ZZ + Stroke LX LZ Z LT (mm) Bore size (mm) LS LC LT LH LX LY S Z LZ ZZ Y X 5.5 83 2.3 14 33 25 65 19 42 108 9 6 10 5.5 92 2.3 18 42 30 74 21 54 119 9 6 16 6.8 137.5 3.2 25 40 40 97.5 20.5 55 166 20 8 20 6.8 142.5 3.2 28 40 47 102.5 24.5

24.5 55 175 20 8 Rod side flange type: MQMLF 6 20 REA 2.3 33 42 27.5 REB 2 x 5.5 66 + Stroke 93.5 + Stroke REC 10, 16, 20, 25 CY CX FY MQ FT RHC FX FZ H 2 x FC S + Stroke ZZ + Stroke RZQ (mm) DBore size (mm) FC FT FX FY FZ H S ZZ -X 10 5.5 2.3 33 20 42 28 65 101 16 5.5 2.3 42 24 54 30 74 114 Individual -X 20 7 4 60 34 75 40.5 97.5 151 25 7 4 60 40 75 44.5 102.5 160 1185 Series MQM Refer

Dummy spacer R16 Individual spacer R1 13-2-33 33 Series ZX Ejector System Manifold Common EXH port End plate Common air supply PV port 4-5.5 mounting holes Manifold base Exhaust adapter Manual override (Push and turn the locking type override.) Adjusting needle Adsorption confirmation switch Manual override (Simply turn the locking type override.)

38 39 44 19.5 24 24 24 11 11 M5 M6 X 0.75 M8 M10 X 1.25 86 96 97 5.5 7 7 9 15 15 15 15 23 25 28.5 33 35 40 40 50 178 193 196 221 30 30 35 35 16 17 17 17 55 62 62 70 198 215 218 241 11 11 11 12 to 200 to 300 to 300 to 300 0.25 Stroke 105.5 Long stroke/Refer to p.3.1-28 and 3.1-29 for mounting dimensions except table below.

(2 m) Z Without lead wire with connector W With lead wire with connector (2 m) + Rubber cover for connector (silicon rubber) ZS-33-F S 1 2 ZS-33-D S 1 2 ZS-33-D IN IN Lead wire length 2 m Lead wire length 2 m Option 2 T Panel mount adapter (For without flow adjustment valve) R Bracket (For without flow adjustment valve) S Bracket (For with flow adjustment valve) Nil None ZS-33-J ZS-33-M

11 11 10 10 14 14 13 14 11 11 11 12 5.5 7 7 9 38 41 41 41 86 96 97 105.5 20 24 24 24 5 6 6 8 19.5 24 24 24 141 151 154 169 33 38 39 44 M5 x 0.8 M6 x 0.75 M8 x 1 M10 x 1.25 Up to 200 Up to 300 Up to 300 Up to 300 0.25 stroke Long Stroke/Refer to pages 9-2-30 to 9-2-32 for mounting dimensions except the table below.

Q G RS H A Bore size (mm) LC LH LS LT LX LY Z ZZ X S LZ Y RZQ 10 5.5 14 83 2.3 33 25 19 108 6 65 42 9 16 5.5 18 92 2.3 42 30 21 119 6 74 54 9 MI W S 20 6.8 25 137.5 3.2 40 40 20.5 166 8 97.5 55 20 25 6.8 28 142.5 3.2 40 47 24.5 175 8 102.5 55 20 CEP1 CE1 Rod side flange style: MQMLF 6 CE2 20 ML2B 2.3 C J G5-S 33 42 27.5 2-5.5 66 + Stroke 93.5 + Stroke CV MVGQ 10, 16, 20, 25 CC RB FY J FT

11 11 10 10 14 14 13 14 11 11 11 12 5.5 7 7 9 38 41 41 41 86 96 97 105.5 20 24 24 24 5 6 6 8 19.5 24 24 24 141 151 154 169 33 38 39 44 M5 x 0.8 M6 x 0.75 M8 x 1 M10 x 1.25 Up to 200 Up to 300 Up to 300 Up to 300 0.25 stroke Long Stroke/Refer to pages 9-2-30 to 9-2-32 for mounting dimensions except the table below.

A B HS HS HS 2020.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 20 27.5 27 24.5 4 5.5 7.5 8.5 2.5 Data 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 30 29.5 27 4 5.5 7.5 8.5 2.5 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 33.5 33 30.5 5 6.5 8.5 9.5 3.5 23.5 (33) 17.5 (27) 20.5 (30) 22.5 (32) 19 (28.5) 40 38 37.5 35 10 11 13.5 14.5 8.5 ( ): Denotes the dimensions

Function Data LRC End 3A 30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS090 Series 4.5 Message configuration 4-9 HRX-OM-T004 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6

Function Data LRC End 3A 30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Read Data1 Byte Count Hi Lo 30 32 30 30 45 45 HRSH Series 4.5 Message configuration 4-9 HRX-OM-R028 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1

Symbol 01 02 1 Stations 2 3 4 5 n U side D side Material Seal material Base material C37 Stainless steel Symbol Nil H FKM Stations Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 02 2 stations 10 10 stations Refer to page 17-2-37 in the L dimension table regarding

VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.

Housing Port Size (1/16 of an inch) Shaft Port Size (1/16 of an inch) Housing Port Configuration: 01 = Male NPTF(Non-Standard)* 02 = Female NPTF 03 = Male JIC 37 Degree 05 = Male SAE O-Ring Straight Thread 06 = Female JIC 37 Degree 07 = Female NPSM Pipe Swivel 10 = Female SAE Straight Thread JM = Seal-Lok Shaft Port Configuration: 01 = Male NPTF 02 = Female NPTF 03 = Male JIC 37 Degree 05

Function Data LRC End 3A 30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS Series 4.5 Message configuration 4-9 HRX-OM-M091 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1

Function Data LRC End 3A 30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRSH Series 4.5 Message configuration 4-9 HRX-OM-Q033 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1

Function Data LRC End 3A 30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS100/150 Series 4.5 Message configuration 4-9 HRX-OM-S010 Chapter 4 MODBUS communication function 4.6 Function codes Table

VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.