Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Besides the models in the above table, there are some other auto switches that are applicable.
ZZ (NN 1) x H G H 5.5 11 11 5.5 B A 3.2 6.5 7 7 12 1 4 NN x M4 x 0.7 thread depth 8 B A 3H9 ( ) depth 2.5 +0.025 0 3H9 ( ) depth 2.5 +0.025 0 HA GA Section AA Section BB (mm) Model F 20 30 20 28 38 ZZ 64 74 84 106 122 M 42 52 62 84 100 Z 41.5 51.5 61.5 83.5 99.5 K 22.5 32.5 42.5 52.5 62.5 J 17 27 40 50 60 I 10 10 7 19 25 NN 2 2 3 3 4 H 25 35 20 30 24 G 6 6 11 13 17 HA 20 20 20 30 48 N 4
ZZ (NN1) x H G 8.5 18.5 8.5 18.5 H B A 4.2 8.5 9 9 20 1 4H9 depth 3.5 +0.030 0 5 B A NN-M5 x 0.8 thread depth 10 4H9 depth 3.5 +0.030 0 HA GA Section AA Section BB (mm) Model F 35 35 35 50 35 55 65 ZZ 99 99 99 111 131 177 231 M 71 71 71 83 103 149 203 Z 70 70 70 82 102 148 202 K 26.5 36.5 46.5 56.5 66.5 91.5 116.5 J 40 40 40 52 60 85 130 I 10 10 10 10 22 43 52 NN 2 2 2 3 3 4 5 HA 40 40 40
Z (Example) A80CZ None . N (Example) A80CN Note 2) Solid state auto switches marked with a "" are produced upon receipt of order.
VY2 17 VBA VBAT AP100 513 Series ARM11A/B Pressure Switch Block 56 ARM11AW Z A 0.6 0.2 0.4 MPa 20 24 56 q w 0.5 0.1 0.3 1. Accessory 2.
Contents Contents MGP12-Z-PS MGP16-Z-PS MGP20-Z-PS MGP25-Z-PS MGP32-Z-PS MGP40-Z-PS MGP50-Z-PS MGP63-Z-PS MGP80-Z-PS 12 16 20 25 32 40 50 63 80 100 Set of nos. above @1, @2, @3, @4 Set of nos. above @1, @2, @3, @4 MGP100-Z-PS 12, 16 15 20 to 100 Nickel plated Carbon steel Hexagon socket head plug Seal kit includes @1 to @4. Order the seal kit, based on each bore size.
type: CHAT Z + 1/2 stroke 2 x Rc P Cushion adjustment screw 4 x J GA TT Air release GB T V Air release Width across flats G MM R (max.)
+ Stroke 10 and 16 Cover surface MM NN GA GB F GC Piping port 3-M5 x 0.8 Piping port M5 x 0.8 CA CB D LY LB LH LT BA 0 -0.3 BB 0 -0.3 LX Head cover port location Axial direction (R) X A Y NA NB 2-LC Mounting hole LZ S + Stroke H Head cover side Rod cover side Z + Stroke (mm) 5 5 12 GA GB 11 11 11 H Bore size Z LZ 32 42 42 20.5 20.5 24.5 NA NB M3 x 0.5 MM M8 x 1.0 NN 57.5 T 3 S 5 5 GC 28
MM 2-LC LX D D I LZ 20, 25 Width across flats B2 Standard port MM Relief port 45 45 Width across flats NA LT N 4-LD N X Y S + Stroke X Y Z LS + Stroke Z + Stroke ZZ + 2 x Stroke 32, 40 (mm) 11 8 8 8 Z H H2 H1 S P N I F A 13 8 AL D K MM NA NN B1 B2 G 54 47 47 40 B ZZ 188 154 152 144 LX 55 40 40 40 LH 30 28 28 25 LT LS LD 4 4 4 4 LC 75 55 55 55 LZ X Y 40 32 25 20 Bore size 1/8 27 25 25 21 24
,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC40B,C,D -(F,N)02~(F,N)04(C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,ZA)-D AC40(A)-(F,N)06(C,D,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC40B,C,D-(F,N)06(C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,ZA)-D AC50(A)-(F,N)06(F,N)10(C,D,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC50B-(F,N)06(F,N)10 (C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,
+ Stroke Spring extend Z + 2 x Stroke RR (mm) CZ 18 22 26 32 32 L 17 22 27 32 38 RR 8 10 10 14 16 Z 113 125 142 169 179 ZZ 121 135 152 183 185 CX 9 11 13 16 16 CDH10 8 10 10 14 14 Spring return ZZ + Stroke Spring extend Z + 2 x Stroke Model MUC25, MUD25 MUC32, MUD32 MUC40, MUD40 MUC50, MUD50 MUC63, MUD63 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 Single/Double clevis material: Cast iron
MXS MXQ 8 x M5 x 0.8 thread depth 13 Note) MXF 6H9 + 0.030 0 depth 5.5 (Insert) 6H9 + 0.030 0 depth 5.5 7 MXW MXJ 72 98 48 MXP MXY Y Y 25 160 40 L 40 40 MTS 11 24 24 K A 60 50 32.5 Z A Bottom through-hole 5.1 N x M6 x 1 thread depth 12 (N-1) x H G H 7 GG HH 6H9 + 0.030 0 depth 5.5 NN x M6 x 1 thread depth 12 Bottom through-hole 5.1 F E 6H9 + 0.030 0 depth 5.5 (mm) DHH H J K L E N F NN G Z
1 High Precision, Digital Pressure Switch For General Fluids Series ZSE F/ISE 50 60 50 60 ZSE ISE PSE Z I SE3 PS Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF Data High precision/High resolution pressure switch.
Refer to Table (3) for the available combinations between each electrical option (S, L, Z) and rated voltage. Option S, Z are not available since a surge voltage suppressor is integrated into the AC/Class B coil, as a standard. Table (1) Port/Orifice Size Normally closed (N.C.)
9 5 1 35 0.2 35 0.2 33.6 46 44 20 6.3 5 2.1 2-M4 x 0.7 (through) M4 x 0.7 x 14.5l and M4 x 0.7 (hexagon bolt) (hexagon nut) 7.5 2-M3 x 0.5 (through) 20 (Z) 4-M3 x 0.5 thread depth 4.5 (same on reverse side) 4-M5 x 0.8 thread depth 4.5 (piping port) (same on reverse side) 7 3 8.5 30 8 Model S ZZ Z SS CXS10-10-XB19 10 82 65 CXS10-15-XB19 15 87 70 30 (20) (Z) 2-M4 x 0.7 Thread depth 7 CXS10-
Coordinates and moments Static moment z Horizontal mounting M3: Yawing M2 M1 y X x Y M1: Pitching m1 x g y x M2: Rolling Ceiling mounting Dynamic moment M2 M1 y Y X x Z M1 m2 x g Wall mounting mn x a M1E M3 M3E mn x a FE FE Y M3 a: Set acceleration degree, : Set speed M2 z X Z m3 x g x Mounting orientation Horizontal mounting Ceiling mounting Wall mounting Dynamic load (FE) Mounting orientation
Fittings & Tubing Air Cylinders Rotary Actuators S ZZ SS 20 10 9 2 x 4.3 through Z 2 x 8 counterbore depth 4.4 18 5 30 1 M6 x 1.0 x 5 L (Hexagon socket set screw) 450.2 450.2 48 56 25 58 6.3 5 2 x M4 x 0.7 thread depth 6 1 M4 x 0.7 x 14.5 L and M4 x 0.7 (Hexagon bolt) (Hexagon nut) 9 M5 x 0.8 x 10 L (Hexagon socket head cap screw) 2 x M5 x 0.8 (Through-hole) (Z) 2 x M5 x 0.8 thread depth
rail mounting (mm) F Model AA Z S M J H MXP6-5 2 45 5 37 33.5 38 25 MXP6-10 9.5 60 10 47 48.5 53 35 8-8-15 15 Series MXP Dimensions: MXP10 2-M3 x 0.5, depth 3 Z 3 Metal stopper 2-M3 x 0.5, depth 5 V K 5 4 G Max. 5.5 Max. 3.5 N 20 M Stroke: S MXP10-10 A Piping port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local
Z Y69BZ Solid state switches marked with a " " symbol are produced upon receipt of order " 1.11-33 Series C95 Auto Switches How to install auto switches ca. Hs A ca.
Lead wire length (m) Indicator light Load voltage Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line AC DC IC circuit 3-wire (NPN equivalent) A96 A96V 5 V Reed switch Solid state switch Grommet Yes Relay, PLC A93 A93V 12 V 2-wire 24 V 100 V F9N F9NV 3-wire (NPN) IC circuit 5 V, 12 V F9P