VJ10-20-4A-6 2 pcs. 5A 10 ZS ZP (For DC) 4A 20 VJ10 6 Lead wire length ZCU Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 AMJ (For 110 VAC) Note) If ordering switch with 5 m lead wire, specify both switch and lead wire with connector part numbers. Ordering example) ZX100-K150Z-ECN1 pc. VJ10-20-4A-6 2 pcs. ZS-10-5A-50 1 pc. 3A 36 VJ10 6 Misc.
30 B 70 70 108 108 Model A 174 174 234 234 ALT-5 ALT-5-IS ALT-9 ALT-9-IS 449 482 1.17-14 Oil Distributor VA, VB/Nylon Tubing Related Products Oil Distributor Series VA, VB How to Order V A 4 6 Applicable tube O.D. 6 6 Oil Distributor Number of distribution ports (VA) (VB) VB6-6 Distribution 4 ports 6 ports 8 ports 4 ports 6 ports 10 ports 16 ports 4 6 8 4 6 10 16 Both sides exhaust One side
V < 2 6 . 6 C # 1 S V 2 5 . 0 C M O D E N o r m a l Fig. 6-3 Alarm indication in the event temp. upper and lower limit occurs LIGHT W R N P V < 2 6 . 6 C # 1 S V 2 5 . 0 C M O D E Remote off Fig. 6-4 Alarm indication in the event Remote off occurs 6.2 Alarm indication 6-2 A_HEC-OM-K001-1.7 Chapter 6 Alarms 6.3 Content of Alarms Table 6-2 Content of alarm (1/2) Temp.
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
VS4 Applicable solenoid valve Flat Ribbon Cable Type 21P How to Order VQ7 05 1 3 5 6 VV5Z5 21P 01 C6 C8 VZ523MOZEVS Applicable blanking plate assembly DXT199-22-3A Applicable connector assembly DXT192-52-1A (For 2 position single) DXT192-52-1A (For 2 position double, 3 position) 1: 100 VAC, 3: 110 VAC, 4: DC Stations P, R port thread type VFN 4(A), 2(B) port 03 3 stations NPT G Nil Rc
(1) (2) Nil 33 30 Note 1) X3 (Wetted parts stainless steel) specifications is not available.
However, for any other mounting method or for side facing and rear facing, etc., secure the DIN rail with bolts at uniform intervals using the following as a guide: 2 to 5 stations at 2 locations, 6 to 10 stations at 3 locations, 11 to 15 stations at 4 locations, 16 to 20 stations at 5 locations, 21 to 25 stations at 6 locations, 26 to 30 stations at 7 locations and more than 30 stations
Confirm that the connector portion does not move. 14.9 Gray: Ground Black: DC24V 10% ( power supply for input and control ) Blue: 0V ( for input and control ) White: DC24V+10%/-5% ( for solenoid valves/output ) 18 48 34 Straight connector Type Angle connector Type EX500-AP -S EX500-AP -A 6 30 5 50 31.3 28.3 6 Socket Connector Pin Layout 4 3 1 5 30 5 50 2 B. Single power supply system A.
location, P/R port with One-touch fitting for 6 VZ1000-3A-1D r VZ1000-3A-1U t SUP/EXH block assembly VZ1000-2A-1M y Note) Block pin (2 pcs.) is attached for q, e, t, y.
Port block assembly (cassette type) Port block assembly (screw-in type) How to Order Connector Assembly For DC : SY100-30-4AFor 100VAC : SY100-30-1AMounting screws For 200VAC : SY100-30-2AFor other AC : SY100-30-3AWithout lead wires : SY100-30-A (connector, socket x 2pcs. only) Lead wire length 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Nil 6 10 15 20 25 30 50 Fitting assembly
LFU20-Z11-3A-X2 ( Includes controller & connectors ) 30 30 2000 2000 LFU20-Z11-1A-X2 LFU20-Z11-3A-X2 (Includes controller & connectors) (Includes controller & connectors)
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
For details about applicable models, please contact SMC. 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC 2-5-30 Base Mounted Series VQ4000 Plug Lead Unit Manifold Specifications Porting specifications Maximum applicable stations Applicable solenoid valve 5 station weight (kg) 4(A), (B) port location Port size Note) Series Base model Type
Weight 30 g (ZL3-) JSY3140 5 5-port solenoid valve JSY3000 series Specific Product Precautions Z Multistage ejector ZL 3 6 series Exhaust noise (Reference values) Z ZL3 6 5 Manual override Model ZL3 ZL6 Exhaust noise [dB(A)] 68 Electrical entry Refer to page 26.
This will cause a malfunction. 14-11-6 6 Pressure Gauge Guide How to Order G M C 46 10 01 X2 Option Specifications Symbol Pressure gauge F.R.L.
Note2) For thread standard, refer to page 2-6-39.
Note2) For thread standard, refer to page 2-6-39.
AV Tightening Torque when Piping Connection thread Applicable torque (Nm) M5 x 0.8 1.5 to 2 1/6 rotation 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 AU Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 Rc 1 1/4 Rc 1 1/2 Rc 2 AF Model Connection R AN120 AN110 AN200 AN300 AN400 AN500 AN600 AN700 AN800 AN900 Effective area (mm2) AR M5 x 0.8 1 8 1 4 3 8 1 2 3 4 5 35