8.3 PFM7-01/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3 36.3 N7 1/4 10.3 8.3 PFM7-01/02--X694 PFM7S-01
Unit 1 Disable Does not generate an error. -10..10 V -5..5 V -10..10 V Selects the analogue input range. (AXB: Cannot select -10..10 V/-5..5 V/ -20..20 mA) -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary. Sign & Magnitude Signed binary.
Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data
C HRZ008-L1-F 16 14 [HRZ008-L1-F] Cooling capacitykW 12 10 8 6 4 2 0 -20 -10 0 10 20 30 40 Circulating fluid setting temp.deg.
--1 ZQA-J25LO--1 ZQA-Q15LO--1 ZQA-Q25LO--VQ100 (ZQ ) Assy(DC24V ) VQZ1000V-85-1A 97mm 41 - No.ZQ-OM01401-B 13. (1),(2) (3),(4) (4),(5) (6) (14) (7) (8) (9) (6),(10) (11) (12) (13) (3),(4), (5),(6),(14) (15) (7) (8) (16) 42 - No.ZQ-OM01401-B No. (1) (2) (3) ON 10 (%) (4) (5) Assy (6) (7) (8) 0.72[V] (9) Ass'y (10) 43 - No.ZQ-OM01401-B No. (11) (12) (13) (14) Ass'y
), 10e), 16e ZP Basic 08 8 NBR U Flat N Nil With (guide) attachment With flange (42 x 42 ) Bellows type for N Without flange ZP3P 10 C S Flat with rib M With mesh attachment 10 Silicone rubber (White) 2 film packaging 13 13 B Bellows U Urethane rubber 3 Only applicable to the cup workpieces form JT.
5/32 inch 4 mm 6 mm 1/4 inch 5/32 inch () PBTCB156PPSO HNBR C3604( ) POMSUS304NBRC3604 SUS304NBR 24 g 34 g 36 g 27 g 28 g 29 g 30 g 30 g 36 g +39 g 0.15mm 2(AWG26) 1.0 mm (5 ) 3.5 -77No.PS-OMU0002CN-D M5 42.6 7 M50.8 3.5 01/N01 A 01 R1/8 10 N01 NPT1/8 12 C4HC6HN7H 2.5 A B C4H 15.6 8 C6H 16.5 10 N7H 16 10.3 C4LC6LN7L C A B C D C4L 15.2 17.5 4 8.2 C6L 15.2 18.3 4 10.4
(Refer to Copy function on page 41.) 36 2-Color Display High-Precision Digital Pressure Switch ZSE30A(F)/ISE30A Series Dimensions Z/ISE30A(F) Piping specifications ZSE20 ISE20 ZSE30 ISE30 ZSE30 ISE30 01 N01 / ZSE40 ISE40 25 8 9.5 1.5 30 200.1 2 x M3 x 0.5 thread depth 4 Lead wire with connector ZSE10 ISE10 ISE70 M5 x 0.8 10 ZSE80 ISE80 200.1 30 01: R1/8 N01: NPT1/8 PS ISA3 Width across flats
Port size NPT Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" From one-touch fitting to male thread B Bushing Type AKB 01 A 01 S With sealant (standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction
(Only for EX510-S 01 ) -34No.EX-OMI0032-G No.
Port size NPT Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" From one-touch fitting to male thread B Bushing Type AKB 01 A 01 S With sealant (standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction
HNBR C3604 SUS304NBR POMSUS304NBRC3604 24 g 34 g 36 g 30 g 30 g +39 g 0.15 mm 2(AWG26) 1.0 mm (5 ) 3.5 -78No.PS-OMU0005CN-C M5 7 3.5 01/N01 A 01 R1/8 10 N01 NPT1/8 12 C4LC6L 4 A B C4L 17.5 8.2 C6L 18.3 10.4 -79No.PS-OMU0005CN-C A B -80No.PS-OMU0005CN-C 0.5~7 + 0.5~7 -81No.PS-OMU0005CN-C 2 (n ) <> <> 31n +3.5(n -1) 31n +3.5(n -1) -82No.PS-OMU0005CN-C Revision history A [2018
Tie-rod For 3 stations 14 mm x 3 stations = 42 mm VY1 VBA VBAT For Centralized Supply Block For 10 stations 14 mm x 10 stations = 140 mm Centralized supply block qty. Tie-rod part no. AP100 Length 136017-1A 136017-2A 1 16 2 32 Note 1) When adding the centralized air supply block, add the tie-rod for centralized air supply to the regulator block tie-rod.
IN Fitting Type Inch size Metric size ARP Common supply block (S) Common supply block with pressure switch (P) Fitting type Fitting type Straight 6 8 10 8 6 10 Elbow Straight 1/4 5/16 3/8 5/16 1/4 3/8 Elbow Symbol Symbol IR-A 01 02 03 13 14 15 51 52 53 63 64 65 5 56 56 5 IR 0.4 0.2 0.6 0.5 SMC 20 MPa 24 20 17 24 56 IRV 0.3 0.1 VEX 32.5 SRH 4.
A 01 R1/8 10 N01 NPT1/8 12 C4HC6HN7H 2.5 A B C4H 15.6 8 C6H 16.5 10 N7H 16 10.3 C4LC6LN7L C A B C D C4L 15.2 17.5 4 8.2 C6L 15.2 18.3 4 10.4 N7L 20.9 20.6 6 11.1 -64No.PS-OMS0006CN-G A B -65No.PS-OMS0006CN-G 0.5~7 + 0.5~7 -66No.PS-OMS0006CN-G 2 (n ) <> <> (n -1) (n -1) -67No.PS-OMS0006CN-G Revision history A B [2016 9 ] C [2018 6 ] D [2020 2 ] E [2021 2 ] F [2022 1 ] G [2022 10 ]
If an instantaneous flow of 10 L/min continues for 5 minutes, the accumulated flow will be 10 5=50 L. Accumulated flow external reset A function to reset the accumulated flow to zero by using an external signal. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.
port Weight Body 24 g 34 g 36 g 27 g 28 g 29 g 30 g 30 g 36 g Lead wire with connector +39g Cable specifications Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 1.0 mm Color Brown, Blue, Black, White, Gray (5 core) Sheath Finished outside diameter 3.5 -77No.PS-OMU0003-D Dimensions M5 type 01/N01 type Piping specifications Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width
connector +39 g Cable specifications Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 1.0 mm Color Brown, Blue, Black, White, Gray (5 core) Sheath Finished outside diameter 3.5 -78No.PS-OMU0006-D Dimensions M5 type 01/N01 type Piping specifications Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width across flats 12 C4L/C6L type Piping specifications A B C4L 17.5 8.2 C6L
Input/output 10 seconds for 4 cables. 10 seconds for 4 cables. Output Elimination of branch unit The function of a branch unit is built-in a 16 point unit, allowing reduction of the number of units.