SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ5-41-04-M5"

CL1 100 M5 x 100 L 105 M5 x 105 L MLGC 110 M5 x 110 L 120 M5 x 120 L 9 CNG 130 M5 x 130 L 155 M5 x 155 L MNB 180 M5 x 180 L 120 M6 x 120 L CNA 130 M6 x 130 L 140 M6 x 140 L 13.5 CNS 165 M6 x 165 L 190 M6 x 190 L CLS 125 M8 x 125 L 135 M8 x 135 L CLQ 145 M8 x 145 L 12.5 170 M8 x 170 L RLQ 195 M8 x 195 L MLU Working Principle MLGP ML1C Locked Unlocked Brake spring Lock ring Piston rod FREE

Model C D Mounting bolt M5 x 90l M5 x 95l M5 x 100l M5 x 110l M5 x 120l M5 x 145l M5 x 170l M5 x 100l M5 x 105l M5 x 110l M5 x 120l M5 x 130l M5 x 155l M5 x 180l M6 x 120l M6 x 130l M6 x 140l M6 x 165l M6 x 190l M8 x 125l M8 x 135l M8 x 145l M8 x 170l M8 x 195l RLQB32-20 RLQB32-25 RLQB32-30 RLQB32-40 RLQB32-50 RLQB32-75 RLQB32-100 RLQB40-20 RLQB40-25 RLQB40-30 RLQB40-40 RLQB40-50 RLQB40-75

RLQB32-20 RLQB32-25 RLQB32-30 RLQB32-40 RLQB32-50 RLQB32-75 RLQB32-100 RLQB40-20 RLQB40-25 RLQB40-30 RLQB40-40 RLQB40-50 RLQB40-75 RLQB40-100 RLQB50-30 RLQB50-40 RLQB50-50 RLQB50-75 RLQB50-100 RLQB63-30 RLQB63-40 RLQB63-50 RLQB63-75 RLQB63-100 M5 x 90l M5 x 95l M5 x 100l M5 x 110l M5 x 120l M5 x 145l M5 x 170l M5 x 100l M5 x 105l M5 x 110l M5 x 120l M5 x 130l M5 x 155l M5 x 180l M6 x 120l

AS2002F-04-X12 Applicable tube O.D. Body size 100 200 205 300 400 Metric size Inch size M3, M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Grease-free (Sealant: Fluoro coated) + Restrictor (Without Check Valve) -X21 02 23 04 06 08 10 12 01 03 07 09 11 13 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)

x 0.8 depth 7.5 M5 x 0.8 depth 8 M6 x 1 depth 12 Without rod boot ZZ e f h l ZZ With rod boot Stroke range Bore size (mm) H1 WA WW WB WH H PG PH PL PW S TA TB P TC W 30 30 25 20 20 25 32 40 178 193 196 221 198 215 218 241 55 62 62 70 16 17 17 17 30 30 35 35 35 40 40 50 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 23 25 28.5 33 11 11 10 10 14 14 13 14 11 11 11 12 5.5 7 7 9 38 41 41 41 86 96 97 105.5 20

B H NTJ-015A NT-02 NT-04 NT-05 M5 x 0.8 7.8 9.2 12 8 4 H B M8 x 1.25 12.5 15.0 20 13 5 M14 x 1.5 21.0 25.4 32, 40 22 8 M18 x 1.5 26 31.2 50, 63 27 11 Electrical Wiring Input/Output The input/output of the scale cylinder is performed by a 7 shielded twisted pair wire from the sensor section plus a connector.

AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 522 Series AS Speed Controller: Standard Type Elbow Type (Metal Body) Note) The flow characteristics are representative values.

M5 M5 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/2 Size 1 2 6 8 8 8 12.8 19 19 23 P 1 Resin body is not available. 2 Other Options, which can be combined, are A, B, D, E, Z. 3 Electrical entry direction 3 2 x M thread Depth D 90 Standard Note) Resin body is not available.

BA-05 BA-06 BA-08 BA-10 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C BM1-01 BM1-02 BM1-32 BM1-04 BM1-05 BM1-06 Note) Two kinds of auto switch mounting brackets are used as a set.

x 0.8 Rod side cylinder port 2 x 5.4 through 2 x 2 x 9 depth of counterbore 7 depth VH Q H thread effective depth C 5.5 M5 x 0.8 unlocking port (Unlocks when pressurized) U I 6.5 VV D M E M5 x 0.8 K M E S 3.2 2 x 2 x M5 x 0.8 3.2 Head side cylinder port 16 16 W Dust cover (Manual unlocking unit) L G B + Stroke A + Stroke Retraction locking LOCK VH1 W1 Dust cover (Manual unlocking unit) M5

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. When changing the detecting position, carry out in the state of 3. Auto Switch Mounting Bracket Part No.

Description ARJM10-4, -6, -10 Manifold base ARJ1020F-M5-06 ARJ1020F-M5-04 How to Order M5 ARJ 20 10 F 04 1 Option 1 0.2 MPa setting Miniature regulator Note 1) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.

, 3/8 VCW31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 59 46 57 60 54.5 48.5 101 57 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 64.5 48 62.5 62 60 50.5 103 62.5 70 107 1/4, 3/8 VCW41 30 50 94 41 13.5 17 36 25 23 M5 8 26 66.5 48 64.5 62 62 50.5 103 64.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 70 48 68 62 65.5 50.5 103 68 70 119 3/4 17-2-55 8 Series VCW Dimensions (N.O.)

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.

Applicable cable O.D. 3.5 to 7 63.9 Max. 10 101.7 56.4 45.1 VEX3121: M5 VEX3122: None (Port PA/Pilot air) M5 (Port PE/ Pilot exhaust) Pg7 M5 (Port P1/Pilot air) M5 (Port P2/Pilot air) Manual override A B P2 P1 102.6 PA 3 R A 2 A 2 64.1 61.8 59.1 58.6 58.1 58.1 1 P 1730 3 Port 3 Position Valve VEX3 Series Dimensions: Body Ported/VEX332 External pilot solenoid: VEX3321 Internal pilot solenoid

NTJ-015A NT-02 NT-04 NT-05 12 M5 x 0.8 4 8 9.2 7.8 H B 20 5 13 15.0 12.5 M8 x 1.25 32, 40 8 22 25.4 21.0 M14 x 1.5 50, 63 11 27 31.2 26 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.