Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11 to 25 VDC How to Order EX500 G DN1 200 mA or less (Single GW unit) Current consumption Communication power supply for DeviceNet 50 mA or less Communication protocol Maximum 64 inputs/
Unscrew the M4 screws (47, 3 pcs.), M3 screws (48, 2 pcs.) and M3 screw (49). Remove the spool valve assembly. The spool valve may be cleaned if special attention is paid to a clean environment and proper procedure. After unscrewing the M4 screws (47, 3 pcs.) the spool valve may be lifted from the fixture.
/h) (282 m3/h) (420 m3/h) (570 m3/h) dew point Standard Outlet air condition 45oF 155SCFM 215SCFM 314SCFM 406SCFM Air flow capacity pressure (7.2oC) (264 m3/h) (366 m3/h) (534 m3/h) (690 m3/h) (ANR) dew point (Note2) Outlet air 50oF 177SCFM 251SCFM 353SCFM 459SCFM pressure (10oC) (300 m3/h) (426 m3/h) (600 m3/h) (780 m3/h) dew point Rated Inlet air pressure 100 psi (0.7MPa) condition Inlet
Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.
, 600 or less with 24 VDC output Power supply voltage 12 to 24 VDC 10% Current consumption 20 mA or less (without load) Enclosure IP65 Environmental resistance Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Voltage resistance 1000 VAC for 1 min. between external terminals and case Insulation resistance 50 M or more (500 VDC
10% 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% Temperature characteristics (25C reference) 3% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F .S.
Series PF2D5 RESET SET PF2D300-A(-M) Panel fitting dimensions 3 x 7.2 (=21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black Main circuit 1 2 3 4 7 3 Load +0.5 0 Brown + 6 2 19.4 Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2D5 PF2D301-A(-M) The applicable panel thickness is 1 to 3.2 mm.
OUT (2) 1 Coil insulation Body material and coil insulation type Symbol Body material Seal material (1) IN Nil A B PPS NBR FKM EPDM Class B Voltage 5 6 24 VDC 12 VDC Symbol Size Series Port connection type G Grommet Coil type P7 P10 C4 C6 C8 C10 30 40 P7 quick fastener P10 quick fastener One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 Power-saving
Applicable mounting screw: M3 (2 pcs.)
(ANR) oil mist concentration (before saturated with hydraulic fluid: 0.01mg/m3 (ANR) or less, approx. 0.008ppm ) Note 1) Pressure gauge connection threads are not required for the regulator with a square embedded type pressure gauge (AWD20 to 40).
Part number Description Note ZS-40-A Lead wire with M8 connector Length: 3 m ZS-42-A Bracket With mounting screws for PFMC7501/7102 (M3 x 5, 2 pcs.) ZS-42-B Bracket With mounting screws for PFMC7202 (M3 x 5, 2 pcs.)
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
Please download it via our website, http://www.smcworld.com 16 Series HRS100/150 Standard Type Communication Function Contact Input/Output Item Specications Connector type M3 terminal block Insulation method Photocoupler Rated input voltage 24 VDC Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 k Input signal Rated load voltage 48 VAC or less/30 VDC
D-P5DWL Auto switch model Applicable load 24 VDC relay, PLC Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA or less Internal voltage drop 5 V or less Leakage current 1 mA or less at 24 VDC Operating time 40 ms or less Operating positionRed LED lights when ON. Optimum operating positionGreen LED lights when ON.
30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/
Please download it via our website, http://www.smcworld.com 175 HRSH Series Inverter Type Communication Function Contact Input/Output Item Specifications Connector type M3 terminal block Insulation method Photocoupler Rated input voltage 24 VDC Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC
kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting
is not provided for the 12 VDC specification.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.