(Example) SYJ3120-5M-M3 VJ3000-13-1 -+ Single Double Rated voltage 5 port DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
SW3 SW4 Power supply voltage Output signal Lower limit of switch output exceeds upper limit. 1 12 VDC 4 to 20 mA DC Switch range error 2 12 VDC 0 to 10 VDC Pressure exceeding upper limit of set pressure is applied. 3 24 VDC 4 to 20 mA DC Pressurization error 4 24 VDC 0 to 10 VDC 206 Series IC Controller for Electro-Pneumatic Regulator Descriptions Description OUT display Displays output specification
Note 2) For interface use, supply 24 VDC 10% 150 mA using an external source. Note 3) The failure (ALM) is ON during normal conditions.
0.8 V or less 3 V or less 14 Vorless Leak current 24 VDC: 10).1A or less 24 VDC 10).1A or less 24 VDC: lmA or less 100 VAC: 1mA or less 200 VAC: 1.5mA or less Indlcetor lamp.
40mA D-K39 D-K39C 2 Wire 10~28 VDC 2V or less ON: Red LED; Green: Best Position 5~40mA D-G59W D-J59W 3 Wire NPN 28 VDC 4V or less ON: Red LED; Green: Best Position 40mA D-G5PW D-F5PW 3 Wire PNP 4V or less ON: Red LED; Green: Best Position 80mA D-G5BAL D-F5BAL 2 Wire 10~28 VDC 4V or less ON: Red LED; Green: Best Position 5~40mA D-G5NTL D-F5NTL 3 Wire NPN 28 VDC or less 2V or less ON: Red
Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.
Electrical entry direction Perpendicular Perpendicular Perpendicular Wiring type 2-wire 3-wire Output type NPN PNP Applicable load IC circuit, 24 VDC relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 80 mA or less 2.5 to 40 mA 1.5 V or less (0.8
Connector 1 2 3 4 5 6 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz Refer to Table (3) shown below for availability. Refer to page 23 for ordering coil only. DIN type is available with class B only.
L N VQ110VQ110YVQ110 ZQ1-VQ120Model Push-locking type Non-locking push type / Locking type (Tool type) Manual override Non-locking push type / Locking type (Tool type) Rated coil voltage 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC 12, 24 VDC DC 100 VAC 110 VAC 200 VAC 220 VAC 1 W 1 W 0.5 W 0.6 VA (6 mA) 0.65 VA (5.9 mA) 1.2 VA (6 mA) 1.3 VA (5.9 mA) Grommet
PLC VElectric actuators *1 Power supply for I/O signal 24 VDC VI/O cable (Option) p. 15 Part no.
collector Max 30 VDC, 50 mA NPN open collector Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less
D-F9PW D-F9PWV D-F9BW D-F9BWV D-F9NW D-F9NWV Electrical entry direction Perpendicular In-line Perpendicular In-line Perpendicular In-line 2-wire Wiring type 3-wire Output type NPN PNP 24 VDC relay, PLC Applicable load IC circuit, Relay PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less 24 VDC (10 to 28 VDC) Load voltage 28 VDC or less Caution Load
(Red Green Red) PLC: Programmable Logic Controller D-P4DWL/Z (With indicator light) D-P4DWL D-P4DWZ Auto switch model 24 VDC relay, PLC Applicable load 24 VDC (20 to 28 VDC) Load voltage 6 to 40 mA or less Load current 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current 40 ms or less Operating time Operating position . Red LED illuminates.
12 VDC 6 VDC 5 VDC 3 VDC ZH Output specifications (Vacuum switch) ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NPN open collector, single output Analog, no output, 3 turn setting 14 ZL Note 1) The serial transmission type is 5 (24 VDC) only.
D-M9N In-line D-M9NV Perpendicular D-M9PV D-M9P Perpendicular D-M9B D-M9BV Auto switch model In-line In-line Perpendicular Electrical entry direction 3-wire Wiring type 2-wire Output type NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load
In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction 3-wire 2-wire Wiring type NPN PNP Output type IC circuit, Relay, PLC 24 VDC relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage 28 VDC or less 40 mA or less 2.5 to 40 mA Load current 0.8 V or less at 10
Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDC For power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator Indicator light Power supply voltage Current consumption 12 to 24 VDC p10% 30 mA or less Note 3) The response time until the Enclosure IP65 set value reaches 90% in relation to the step
Power saving circuit is only available in the "Z" type. 3 position pressure center Bracket Nil: Without bracket F: With bracket Rated voltage AC (50/60 Hz) DC 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] A, B port size M5 C4 C6 N3 N7 M5 x 0.8 One-touch fitting for 4 One-touch fitting for 6 For type W, DC voltage is only available.
How to Order Relay output module SV 000 60 A 5 1A Light window No. of output points Series A B 1 output 2 outputs 1 2 3 4 10-SV1000 10-SV2000 10-SV3000 10-SV4000 Rated voltage 5 6 24 VDC 12 VDC Note that serial wiring manifolds (EX500, EX250 and EX120) are available with 24 VDC only.
Current consumption 24 VDC (10 to 28 VDC) Load voltage 28 VDC or less 40 mA or less 2.5 to 40 mA Load current 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating position .