operating pressure Minimum operating pressure Proof pressure Ambient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance (m/s2) Enclosure Coil rated voltage Allowable voltage fluctuation Coil insulation type Air/Inert gas 1.0 MPa 0.1 MPa Valve specifications Electricity specifications VFN 1.5 MPa 10 to 50C (1) Non-lube (2) Non-locking push type (Flush) 150
Weight 13 mm or less 140 g 140 g Tube Cutter: TK-3 (Useful type) Safety lock contained Safety lock (released) Note) Do not use it to cut the metalic materials such as electric wires. TK-3 Nylon, Soft nylon, Polyurethane, and other soft plastic tubing Model Applicable tubing material Applicable tubing O.D.
120 140 160 0 20 40 60 Gripping point L (mm) MHL MHR Confirmation of Gripping Point Step 2 MHW MHY MHK 200 60 MHS H H 50 MHW2-20D 150 Overhang H (mm) Overhang H (mm) MHW2-25D MHW2-32D MHW2-40D MHW2-50D MHC 40 MHY2-10D MHY2-16D MHY2-20D MHY2-25D Gripping point 100 30 MHT 20 50 MHY 10 MHW 0.4 0.5 0.6 0.7 0 0 0.1 0.2 0.3 0.1 0.2 0.4 0.5 0.3 0.6 Gripping point Pressure P (MPa) Pressure P (MPa
F 150 < 422 (max.) 3 Confirmation of specifications and precautions YES 4 Calculation of kinetic energy E1 Calculate kinetic energy E1 by using the formula according to the impact type. Kinetic energy E1 4 Use Formula to calculate E1 by using 5.0 for m and 0.5 for .
W (44) (Y) Z (X) (V) T R T 25 IN port 2 x 3/8 l=280 l=300 : Thread type Plug provided on U side at shipping. 2.5 (N) E A (U) S Q D G C C B L1 L2 L3 16 D side U side Stations 1 2 3 4 5 n 21 5.5 16 OUT port n x 1/4 H H P = J (Pitch) 2 n x 1/8 : Thread type L Dimension (mm) n (stations) Model Dimensions 2 3 4 5 6 7 8 9 10 L1 70 105 140 175 210 245 280 315 350 VV2CL2 L2 82 117 152 187 222 257
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Description Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 105 105 (5) Size: Perform setting as shown below.
Note 2)For interface use, supply 24 VDC o10% 150 mA using an external source. Note 3) The failure (ALM) is ON during normal conditions. When it is OFF (alarm occurs), stop the sequencer signal using the sequence program.
13-3010 SGH(A)23-3015 SGH(A)33-3020 SGH(A)43-3025 SGH(A)13-7010 SGH(A)23-7015 SGH(A)33-7020 SGH(A)43-7025 7.5 42 (1.8) 3/8 9.4 65 (2.7) 1/2 2-port 7 MPa 12.4 112 (4.7) 3/4 100 VAC 50/60 Hz 15.4 155 (6.5) 1 200 VAC 50/60 Hz 56 (2.3) 9.4 50 (2.1) 3/8 11 110 VAC [115 VAC] 50/60 Hz 73 (3.0) 10.5 55 (2.3) 1/2 3 MPa 15 12 90 (3.8) 92 (3.8) 220 VAC [230 VAC] 50/60 Hz 3/4 15.2 135 (5.6) 140
NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.
Weight (g) CRBUW10 CRBUW15 CRBUW20 CRBUW30 90 Vane style Model 180 180 180 180 270 90 270 90 270 90 270 Rotation angle 47.5 47.1 73 72 143 142 263 258 47 72 140 255 Body of the rotary actuator Single vane Auto switch unit + 2 auto switches 30 30 50 60 Angle adjusting unit 30 47 90 150 Rotation angle 100 100 100 100 90 90 90 90 62.2 63.2 77 81 151 158 289 308 Body of the rotary actuator Double
Fine Lock Cylinders Lock-up Cylinder Series CL 16, 20, 25, 32, 40, 50 63, 80, 100, 125, 140, 160 Locking in both directions is possible. Locking in either side of cylinder stroke is possible, too. (The lock-up cylinder can be locked only in one direction.)
60 60 150 60 60 ZH Air consumption Suction flow rate 100 40 40 100 40 40 ZH -X267 Suction flow rate 50 20 20 50 20 20 ZHP ZU 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 20 40 60 80 Supply pressure [MPa] 0 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 20 40 60 80 100 120 140 0 0 Suction flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Supply pressure [MPa] VQD-V ZH20SA ZH20LA Exhaust Characteristics Flow
1 1/2 Short 0.63 to 1.95 26 52 140 125 2 Middle 0.34 to 1.06 23 45 IF IF31-10 280 250 2 1/2 Middle 0.41 to 1.29 45 90 Data 250 220 3 Middle 0.26 to 0.81 40 80 550 480 4 Long 0.33 to 1.05 85 170 Long 1,000 870 5 0.37 to 1.24 150 300 Long 1,500 1,300 6 0.40 to 1.32 230 460 110 100 1 Short 1.00 to 3.05 18 36 160 140 1 1/4 Short 0.90 to 2.67 27 54 270 230 1 1/2 Short 1.10 to 3.29 45 90 270 230
Steel) Pressure Gauge For OUT 1, OUT 2 pressure range 0-150 psi, 1/8 NPT G43-P10-N01 or KSlOB-AD11 (St.
Steel) Pressure Gauge For OUT 1, OUT 2 pressure range 0-150 psi, 1/8 NPT G43-P10-N01 or KSlOB-AD11 (St.
Substitute 11.7 J for E and 0.3 for . 30.7 36.8 43.0 67.5 73.6 92.0 153 J 38.5 46.2 53.9 84.7 92.4 115 192 Substitute both absorbed energy E and collision speed for Data A in order to calculate the corresponding weight of the impacting object. 50.3 60.3 70.4 111 121 151 251 Me 260 kg D63.6 76.3 89.1 140 153 191 318 7.
(60) 32 (0) 50 (10) 68 (20) 86 (30) 104 (40) 122 (50) 140 (60) 158 (70) 176 (80) F (C) Ambient temperature (Air compressor intake air temperature) Pressure dew point Dew Point Conversion Chart How to calculate the amount of condensed water 140 (60) Example) To obtain the amount of condensed water when the pressure is applied to air up to 102psi (0.7 MPa) with an air compressor, then cooled