SMC Corporation of America
Elite Part Number Search
Search Results "RZQD32TF-175-80"

MPa] When the arm length is 80 mm, pressure should be MK20/25: 0.45 MPa or less, MK32/40: 0.55 MPa or less.

External Pilot Solenoid Type (Conduit terminal) A B C D E F G H I J K L M N O Model SGH12-7010 SGH22-7015 SGH321-7020 SGH322-7020 SGH421-7025 SGH422-7025 Main port Pilot port 60 28 29 116 34 60 24 29 125 37.5 75 62 10.5 16 2 x 3/8 1/8 77 33 32 133 20 44.5 80 36 25 142 50 100 70 12 16 2 x 1/2 1/8 96 43 39 157 24 60.5 100 49 34 169 63 126 92 20.5 19 2 x 3/4 1/4 96 43 39 142 24 60.5 100 49

flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C) IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFB15E IDFB22E IDFB37E IDFB55E IDFB75E NPT3/8 10(17) 11(19) 12(20) ZFC NPT1/2 15(25) 16(27) 17(28) 25(43) 26(45) 28(47) SF 100F (37.8C) 100psi (0.7MPa) NPT3/4 41(70) 43(74) 45(77) 59(100) 62(106) 65(110) SFD 71(120) 80

Applicable cable O.D. 3.5 to 7 Station L1 L2 3 80 68 Station 20 403 391 6 137 125 8 175 163 10 213 201 Station 2 61 49 4 99 87 5 118 106 7 156 144 9 194 182 11 232 220 12 251 239 13 270 258 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 19 384 372 636 3 Port Pilot Solenoid Valve 10-SYJ700 Type 40 Manifold: Bottom Ported/10-SS3YJ7-40Stations -01 [ ] for AC Grommet (G) 5 L2 L1 53.5

Dimensions Formula: L1 = 41n + 77, L2 = 41n + 175 * L2 is the dimension without I/O Unit.

L X P Table displacement (m) Table displacement (m) LXPB-200 LXPB-200 1500 1500 LXPB-175 LXPB-175 1000 1000 LXPB-150 LXPB-150 LXPB-125 LXPB-125 LXPB-100 LXPB-100 500 500 LXPB-75 LXPB-75 LXPB-50 LXPB-50 0 Weight (kg) 0 Weight (kg) 1 2 3 4 5 6 1 2 3 4 5 6 Displacement at the section indicated by the arrow when a load is applied to this section with the slide table fully extended.

Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.

Dimensions Formulae L1 = 11n + 15.5 L2 = 11n + 55 n: Stations (max. 16 stations) L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 191.5 231 262.5 273 16 L1 L2 (L3 ) (L4 ) 26.5 66 87.5 98 37.5 77 100 110.5 48.5 88 112.5 123 59.5 99 125 135.5 70.5 110 137.5 148 81.5 121 150 160.5 92.5 132 162.5 173 103.5 143 162.5 173 114.5 154 175 185.5 125.5 165 187.5 198 136.5 176 200 210.5 147.5 187 212.5 223 158.5

As a general rule, mesh of about 80 to 100 can be used. 4. Be sure to observe the maximum operating pressure. Operation above the maximum operating pressure can cause damage. In particular, avoid application of pressure above the specifications caused by water hammer.

(Note: l,/aximum speed for 80 & 100mm bore s ze is 28 in/sec ) Engineercd pislon Urethane bumpers available as I Available in I bore sizes and 9 different mounting styles.

Note 3) Refer to the operation manual for handling of the remote controller. 0 to 45C 35 to 80% RH (with no condensation) 33 g (excluding dry cell batteries) CE Ambient temperature Ambient humidity Weight Standards/Directive Construction IZS40 series y r t q e Description No.

www.stevenengineering.com I 6.13 VACUUM VACUUM PADS SERIES ZP F L AT T Y P E F L AT W I T H R I B Y D I M E N S I O N S PA D D I A M E T E R S 10, 13, 16 Model A B C D E F G H I Flat Flat with Rib ZPR10 U C 10 12 12 21 29.9 46 57 80 91 3 1.7 ZPR13 U C 13 15 12 21 29.9 46 57 80 91 3 1.8 ZPR16 U C 16 18 12.5 21.5 30.4 46.5 57.5 80.5 91.5 3.5 1.2 D E E P T Y P E D I M E N S I O N S PA D D I

Pulling Strength Model Without inner sleeve With inner sleeve TU1208 140 N 500 N TU1065 140 N 450 N TU0805 110 N 250 N TU0604 80 N 180 N TU0425 50 N 160 N Reference: Thrust Force Occurring at 0.8 MPa Model Load TU0425 10 N TU0604 25 N TU0805 40 N TU1065 65 N TU1208 90 N Note 3) Please consult with SMC regarding applicable tube separately.

In general, a mesh of about 80 to 100 is a guideline for the filter. 3. Liquid rings In cases with a flowing liquid, provide a by-pass valve in the system to prevent the liquid from entering the liquid seal circuit. 4. This solenoid valve cannot be used for explosion proof applications.

Stainless Steel Cylinder Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 For use in environments with water spray such as food processing machines Stainless Steel Cylinder Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Uses grease for food processing machines that meets FDA (U.S.

100 12, 16, 20 25, 32, 40 50, 63, 80 100 20, 25 32, 40 50, 63 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 10, 16 20 25, 32 12, 16 20, 25 32, 40 6, 10 15, 20 25, 32 6, 10 16 20, 25 32, 45 6, 10 16 20, 25, 32 40, 50 10, 15 25 12, 16 20, 25 Bore sizes (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed Shock absorber (optional for CX2) No rubber bumper No rubber bumper Double-side

Body ported Bore size Series CJ2 Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load rate: 50% Stroke 1000 mm 6 10 16 125 140 160 20 25 32 40 40 50 63 80 100 Series MB/CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation

Printed in Japan. 1st printing February, 2002 D-DAD P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.

S n Auto switch Without auto switch (Built-in magnet) Nil Bore size (Stroke (mm)) For the applicable auto switch model, refer to the table below. 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Option Nil Standard (with urethane bumper) With shock absorbers 2 pcs.