(W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.
CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin arrangement CS1 3 4 4 3 3 C76 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300 m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand
CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin
How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC
Bore size Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
Table 8.1-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70
10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300 Minimum Strokes for Auto Switch Mounting Unit: mm (in) D-Z7, Z8 D-Y5, Y6, Y7 D-Y7W, D-Y7BAL 180, 200 2 pcs.
(N) 32 12 0.3 0.5 Deflection (mm) Deflection (mm) MTS32-200 st 175 st 150 st 125 st 100 st 75 st 50 st 25 st 0.2 MTS12-100 st 75 st 0.1 50 st 25 st 0 50 100 0 5 10 Lateral load (N) Lateral load (N) 40 16 0.3 0.3 MTS40-200 st 175 st 150 st 125 st 100 st 75 st 50 st 25 st Deflection (mm) Deflection (mm) 0.2 0.2 MTS16-100 st 75 st 50 st 25 st 0.1 0.1 0 50 100 150 0 10 Lateral load (N) Lateral
0.9 1 Operating pressure P (MPa) Operating pressure P (MPa) -X Selection Graph (6) to (8) (Horizontal mounting) 20Data Graph (6) l: 100 mm or less Graph (7) l: 101 to 200 mm Graph (8) l: 201 to 300 mm 300 100 200 100 100 Load weight m (kg) Load weight m (kg) Load weight m (kg) 80 80 80 10 10 10 63 63 63 50 50 50 40 1 1 1 25 20 25 20 40 32 40 32 32 [Example w] 25 20 0.3 0.3 0.1 70 100 1000
CS2 [mm] Dimensions other than the table below are the same as those on page 50.
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 500 1000 Not available with air cushion. Other strokes available on request.
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 1000 500 Not available with air cushion. Other strokes available on request.
motor (S3) 200 W AC servo motor (S2) 200 to 230 VAC 50/60 Hz AC servo motor (S4) 400 W AC servo motor (S3) Power supply voltage AC servo motor (S6) 100 W AC servo motor (S4) 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz Absolute AC servo motor (S7) 200 W AC servo motor (S6) 100 to 120 VAC 50/60 Hz AC servo motor (S8) 400 W AC servo motor (S7) Pulse input type (For absolute encoder
Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Valve model Pilot valve model Note) VQZ115-L VQ110-M Note) For the special voltages, please consult with SMC. VQZ115-M VQ110-L 4-14-41
MTS12-100 st 100 st 75 st 75 st 0.1 50 st 25 st 50 st 25 st 0 50 100 5 10 Lateral load (N) Lateral load (N) 40 16 0.3 0.3 MTS40-200 st 175 st 150 st 0.2 0.2 125 st 100 st 75 st 75 st MTS16-100 st 50 st 0.1 0.1 50 st 25 st 25 st 0 50 100 150 10 Lateral load (N) Lateral load (N) 20 0.5 Caution on Design MTS20-200 st 175 st 150 st Caution 1.
Hz) 220 to 240 VAC (60 Hz) 5 HRG0024 kVA 380, 400, 415 VAC (50 Hz) 380 to 440 VAC (60 Hz) 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) 3-phase single HRG0057 kVA 6 HRG01014 kVA 440, 460 VAC (50 Hz) 440 to 500 VAC (60 Hz) HRG0157 18 kVA 3-phase double 220, 240, 380, 400, 415, 440 VAC (50/60 Hz) 8 200 VAC (50/60 Hz) Note) Refer to page 32 for dimensions.
Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
CDA2 B 50 200 X1184 B31J S With built-in special magnet Number of auto switches Cylinder stroke Description 2 pcs. 1 pc.
Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
Table 8-1 Water quality criteria for clear water (tap water) Item Unit Standard value For circulating fluid For facility water pH (25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness