1 3/4 5 1/8 NI-1200 2 1/4 4 2 1/2 1 3/4 2 1 1/2 -12 NCA1-1400 2 5 1/8 NI-1400 3 5 2 1/2 2 2 1/2 1 7/8 -12 NCA1-1401 2.5 6.19 NI-1401 3 1/2 5 13/16 3 2 1/2 2 13/16 2 1/4-12 NCA1-1402 3 6.25 Note) Retainer Rings are included NI-1402 3 1/2 6 1/8 3 3 3 1/4 2 1/2-12 42 Medium Duty Air Cylinder Series NCA1 How to Order Auto Switches Wire Lead Type Connector Type D D PC Lead wire length 0.5 (m)
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Applicable Cylinder Series: CDQP2lll-lS/-lT (Axial piping, Single acting) (mm) D-M9l D-M9lV D-M9lW D-M9lWV D-M9lAL D-M9lAVL D-A72/A7lH/A80H D-A73C/A80C/F7l D-F79F/J79/F7lV D-J79C/F7lW D-J79W/F7lWV D-F7BAVL/F7BAL Auto switch model D-A73 D-A80 D-A79W D-A9l D-A9lV D-F7NTL Bore size A B A B A B A B A B 2 A B 7 (11) 6 11 (15.5) 10 3 (7.5) 2 6 (10.5) 5 5.5 (10) 4.5 3 (7) 12 6.5 (8.5) 9 (7) 10.5
Lead wire length (m) Prewire connector Auto switch model Load voltage Indicator light Wiring (Output) Special function Electrical entry Band mounting (6, 10, 16) Rail mounting (10, 16) Applicable load Type 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC Perpendicular In-line 3-wire (NPN equivalent) A76H C76 5 V IC circuit Reed switch Solid state switch Grommet A72H A73H A72 A73 A73C C73 C73C 200
In-line 3 wire (NPN) C76 A76H 5V IC Yes Reed switch Solid state switch A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV A72H A73H A80H 200V Ex.
D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style .
L D-A73 (Example) RS H A Lead wire length RZQ 5 m None Nil L 0.5 m 3 m Z N MI W S Applicable for the connector type (D-C) only.
L D-A73 (Example) CS1 Lead wire length C76 5 m None Nil L 0.5 m 3 m Z N C85 Applicable for the connector type (D-C) only.
L D-A73 (Example) -X Lead wire length 205 m None Nil L 0.5 m 3 m Z N Data Applicable for the connector type (D-C) only.
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
L D-A73 (Example) CLQ Lead wire length MLGP 5 m None Nil L 0.5 m 3 m Z N RLQ Applicable for the connector type (D-C) only.
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
L D-A73 (Example) MHY Lead wire length MHW 5 m None Nil L 0.5 m 3 m Z N MRHQ Applicable for the connector type (D-C) only.
A76H A96V A96 IC 5V A72 A73 A72H A73H 200V Yes Yes No No Yes Yes Grommet Reed switch 12V 100V A93V A90V A93 A90 Option Part No.
auto switch with 5 meter lead wire ("Z") Reed switch: D-B53/B54, D-C73 (C)/C80C,D-A73(C)(H)/A80C D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard (Except D-F9/F9lV) Note 2) The standard lead wire length of solid state switch with timer or with water resistant 2 color indication is 3 meters.
Contact protection box CD-P11 LED Brown OUT Brown Choke coil Resistor Reed switch ~ Zener diode Surge absorber OUT Blue Blue Mass (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown 77 5 Contact protection box CD-P11 CD-P12 Resistor Reed switch Zener diode ~ OUT () Blue Dimensions (mm) Blue 8 3.2 Indicator light D-A80 without