How to Order Burst Pressure Characteristics Curve and Operating Pressure 100 TRB1075 B Burst pressure TRB0604 Tubing model Length per roll Color Burst pressure (For other than TRB0604) Symbol Color Symbol Color BU Blue Y Yellow G Green Symbol Length Burst pressure (MPa) B Black 20 100 20 m roll 100 m reel W White R Red Maximum operating pressure (TRB0604) Maximum operating pressure (For other

Tighten bolt b in numerical order to assemble the body and the bonnet assembly. When tightening bolt b, tighten manually until the O ring is compressed, then perform extra tightening in diagonal order. For models with heater, tighten bolt a to mount the heater to the body.

Barb cassette creeps into the direction D and the tube will be clamped at the B clamp portion (5) consisting of barb (3) and case.

Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 2 XL-OMV0002 1. 2. 3. 4., / 1 1.5 *3) *3)1 1 () 3 XL-OMV0002 1.1 A6063SUS316LSUS304 FKM XLC-80,XLC-100,XLC-160 :Y-VAC2 60 XLC-16,XLC-25,XLC-40 0.3MPa0.5MPa XLC-50,XLC-63,XLC-80,XLC-100,XLC-160 0.4MPa0.5MPa 245250Hz 30m/s (/H0 H4 H5) 4 XL-OMV0002 510 O 0.1mm0.2mm Assy O 5 P11 O 6 (P12P14) 5 XL-OMV0002 2.2

P23 -1- *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: *2) 1.

4-dN through I-dO countelbore Widlh across llals: K B + Stroke With cancel cap/RSlODtl-:f f C ' Dimensions ol lhe model wilh a cancel cap are the same as those shown in the above drawings. s u ' Dirnensons lof lhe matimum energy absoption Fixed mounting l'reishtS9fieS RSQ ' D mere ons ohff than lhose sfswr in lli lab e beNalhe same 6lhedawinss below mm With locking mechanism M o d e l B N

Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

Description Material PBT Brass Brass Note) Handle Needle Lock nut Needle guide Washer O-ring Silencer Silencer cover Body B Gasket q w e r t y u i o !

Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

B L1,L2,L3: A L,N: PE A PE IDF60-20-T IDF70-20-T IDF80-20-T IDF90-20-T M3.5 M4.0 8.5mm 9.5mm IDF60-30-T, IDF70-30-T,IDF80-30-T, IDF90-30-T M3.5 8.5mm [3.2.5 ] IDF60/70/80/90 Series 12-3 IDX-OM-W093 T 12.5 IDF60/70-20-T A B AC 200/200,220V 50/60Hz CM OLR FM MC MC2 PRS PRS2 ILS THR C01 C11 TB CN GFCI EDV PE TDR BK WH GR SY BU IDF80/90-20-T BR B A A B YE AC 200/

Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

4-dN through I-dO countelbore Widlh across llals: K B + Stroke With cancel cap/RSlODtl-:f f C ' Dimensions ol lhe model wilh a cancel cap are the same as those shown in the above drawings. s u ' Dirnensons lof lhe matimum energy absoption Fixed mounting l'reishtS9fieS RSQ ' D mere ons ohff than lhose sfswr in lli lab e beNalhe same 6lhedawinss below mm With locking mechanism M o d e l B

Color of lead wire Black Symbol Contact C Z I SE3 Common A White Normally Open B (N.C.) B PS Red Normally Closed IFW50--55/56 Z I SE1 2 ZSP e Color of lead wire Black Symbol Contact q Power supply (Common) ISA2 w Red Terminal (Relay terminal) w 24 VDC Blue e Power supply (Light terminal) IS N.O.

CKZT 50 A015 C S Symbol D D Bore size S 6 9 050 50 equivalent B 8 10.2 063 63 equivalent Offset Arm mounting position A015 Offset 15mm A045 Offset 45mm Replacement Parts S063 Switch Kit CKZ5 T Proximity switch The switch kit includes a switch cassette assembly and mounting brackets.

A IDFA60-23-T IDFA70-23-T IDFA80-23-T IDFA90-23-T M3.5 8.5mm M4.0 9.5Mm [3.2.5 ] IDFA60/70/80/90 Series 12-3 IDX-OM-W094 T 12.5 IDFA60/70-23-T A B AC 230V50Hz CM OLR FM MC MC2 PRS PRS2 ILS THR C01 C11 TB CN GFCI EDV PE TDR BK WH IDFA80/90-23-T A B A B GR A B AC 230V50Hz SY BU BR YE OR G/Y / IDFA60/70/80/90 Series 12-4 IDX-OM-W094 V 13 V V 13.1 0 () 13.2

Color Symbol Color B Black W White R Red BU Blue G Green 15-6-10 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.

Operating vacuum pressure 100 kPa Proof pressure 3.0 MPa Ambient and fluid temperature 5 to 60C (No freezing) Mounting section JIS B 0203 (Taper thread for piping) Thread JIS B 0209 Class 2 (Metric coarse thraed) Nut section JIS B 0211 Class 2 (Metric fine thread) Sealant (Male thread) With thread seal Copper-free (Standard) Brass parts are all electroless nickel plated Principal Parts Material

(mm) Effective area (mm2) Urethane Soft nylon L M1 Weight (g) D M2 Model a b Applicable thread Applicable thread a b KAH23-04 32.5 34.5 38.5 18.5 21 4 3.2 6 4 15.5 16 17 18.5 20.9 10.4 12.8 15.2 16 17 18.5 28.2 28.2 16.7 16.7 6 4 3 KAH04-06 KAH06-08 10.7 10.7 4.2 4.2 3.2 2.7 8 6 10 8 KAH08-10 42 44.5 21 22 11 14 KAH10-12 10 12 15-3-23 Series KA Union Elbow: KAL Effective area (mm2) Urethane