(Or None in the Case of No Switch), Environmental Options: XC22 (Fluororubber Seals)
(Or None in the Case of No Switch), Environmental Options: XC22 (Fluororubber Seal)
(Or None in the Case of No Switch), Environmental Options: XC22 (Fluororubber Seal)
[Or None in the Case of No Switch], Option: XC22 (Fluoro Rubber Seals)
(Or None in the Case of No Switch), X Option: XC22 (Packing Fluoro Rubber)
(Or None in the Case of No Switch), X Option: XC22 (Packing Fluoro Rubber)
Magnet: Built-in, Mounting: MF1, Front Flange, Bore Size: 1 1/2", Stroke: 1", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MF1, Front Flange, Bore Size: 2", Stroke: 10", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MS1, Foot, Bore Size: 2 1/2", Stroke: 3", Air Cushion: No Cushion, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MS1, Foot, Bore Size: 2 1/2", Stroke: 5 1/2", Air Cushion: No Cushion, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MX0, Basic, Bore Size: 1 1/2", Stroke: 4", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: MS1, Foot, Bore Size: 2", Stroke: 12", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 5 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. [Or None in the Case of No Switch], Option: Fluoro Rubber Seals
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto