Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232
. *5 Inlet pressure: 0.7 MPa Flow at 20C, atmospheric pressure, and 65% of the relative humidity 7 Compressed Air Preparation Filter AFF/AM/AMD Series Line Filter AFF Series Flow Rate Characteristics (Representative values) AFF/AM/AMD AMK Modular Connection Example Compressed air over the max. flow capacity line in the table below may not meet the specifications of the product.
/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 460 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.25 0.3 0.25 0.25 0.2 Free flow 0.2 0.3 0.2 0.3 0.4 Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C
3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow Free flow Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 1580 1710 460 920 Sonic Conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C
MPa Min. operating pressure 5 to 60C (No freezing) Ambient and fluid temperature 20 turns 10 turns Number of needle rotation With seal Option 74 11.5 36 Weight (g) Flow rate (l/min (ANR)) 38 7 12 Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (l/min (ANR)) 420 105 280 Effective area (mm2) JIS Symbol Free flow 6.5 1.6 4.3 Note 1) Flow rate values are measured at 0.5 MPa and 20C
TMH ASD AS Maximum return speed (mm/s) 100 200 300 Speed Controller Cylinder Solenoid valve Tubing Silencer AS-FE 6 ASD230FG CJ2 SYJ500 TU0604 1 m AN11001 KE 10 16 Cylinder size AS-FG AS-FG 20 ASD330FG CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 AS-FP 32 Values at 0.5 MPa and 20C.
REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 7 12 Air flow (l/min (ANR)) 38 Controlled flow CX 0.1 0.2 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C In-line Type RHC Air Flow/Effective Area MK(2) AS2001FM
Elbow Type (Metal body) Air Flow/Effective Area AS220M-02 AS120M AS220M-01 Model R 1/4 Cylinder side M5 x 0.8 10-32 UNF NPT 1/8 NPT 1/4 R 1/8 Port size Rc 1/4 Tube side Rc 1/8 Air flow (L/min (ANR)) 38 7 12 REA Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (L/min (ANR)) 420 105 280 REB Free flow Effective area (mm2) 6.5 1.6 4.3 Note) Supply pressure: 0.5 MPa, Temperature: 20C
Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.
Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 min, AC 1000 Cannot be used for transfer wiring.
Note Conductor resistance W/km, 20C 65 or less 1.5 m AXT100-DS25-015 Cable 0.3 mm2 x 25 cores 3 m AXT100-DS25-030 5 m AXT100-DS25-050 Approx. 10 Voltage limit VAC, 1 min. 1000 L Insulation resistance MWkm, 20C 5 or more * For other commercial connectors, use a 25pin type female connector conforming to MIL-C-24308. * Cannot be used for transfer wiring. 44 8 Note) The minimum bending radius
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures.
Fixed end Bend the tube into the U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the deformed ratio of the tube diameter at bending reaches 5%.
REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 Air flow (l/min (ANR)) 38 Controlled flow CX 0.2 0.1 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South
The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
[Example of setting] Circulating fluid SP: 20C (1) High Temp. Circulating fluid temperature rise (AL10): 22C (2) Low Temp.
servo motor (100/200 VAC) Encoder Incremental 17-bit encoder (Resolution: 131072 p/rev) Horizontal 45 65 Power consumption [W] *5 Vertical 145 175 Horizontal 2 Standby power consumption when operating [W] *6 Vertical 8 Max. instantaneous power consumption [W] *7 445 724 Type *8 Non-magnetizing lock specifications Lock unit Holding force[N] 131 255 157 308 197 385 Power consumption [W] at 20C