DIN rail type, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, .00000 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation
DIN rail type, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, .00000 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation
DIN rail type, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide
DIN rail type, 32MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 11.90496 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation
Lubrication Manual override Impact/Vibration resistance (2) Enclosure VV061 Non-locking push type 150/50 m/s2 VT325-C VV100 Dustproof Note 1) Based on dynamic performance test, JIS B 8419: 2010.
Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Heat resistant lead wire (between sensor unit and amplifier unit) 3.4 Lead wire Oilproof heavy-duty vinyl code (amplifier unit grommet) 3.4, 0.2 mm2, 3-wire, 3000 mm Impact resistance Sensor unit: 1000 m/s2, Amplifier unit: 300 m/s2 Insulation resistance 50 M or more under the test voltage 500 VDC (between lead wire and case) Withstand voltage 1000 VAC, 1 min.
Description Extract Initial input value Input range ORIG direction 2 1:CW , 2:CCW Note1) ORIG mode 1 ORIG limit 100 ORIG time 100 ORIG speed 20 ORIG ACC /DEC 1000 Creep speed 10 ORIG sensor 0: Disable Note 1) CCW direction: motor side origin, CW direction: end side origin. Become effective after restarting the controller. -9- 2.
CN1IF (CONT) 19 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SW OFF RWw(n+1)b0 ON(1) (LEC) (LEC)(LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB ) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.CN2TB/PC () 20 - .CN4 6.1 1 EMG+ EMG 2 EMGEMG 3 24V 5 4 3 2 1 () 4 0V 5 FG FG (LEC)(0V)
Table 8-15 Compliance EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC CE Marking Machinery Directive 2006/42/EC SEMATECH S2-93, S8-95 SEMI S2-0703, S8-0701, F47-0200 UL E229305 / UL1995 HRZ Series 8.7 Compliance 8-25 HRX-OM-I051 Chapter 8 Appendix Serial No. Model: Judgment 8.8 Thermo Chiller Daily Inspection Sheet Circulating fluid supply port cap Looseness IN press.
to 9800mm/s2 Note) Note) There are cases in which the position, speed and acceleration designations are not realized, depending on the actuator that is connected and the operating conditions.
For lead wire length (1000 mm) Solenoid valve: VZ2150-5M0-015 pcs. Connector assembly: DXT170-80-4A-105 pcs. Crimping the Lead Wire and Socket Peel 3.2 to 3.7 mm of the tip of lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. Be careful so that the cover of lead wire does not enter into the crimping part.
Cylinder Speed Chart Bore size Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Enclosure Series Average speed (mm/s) IP65 compatible T kit (Terminal block box) 5 wiring types have been standardized to facilitate easy wiring work and maintenance.
Data 0.1 YES Caution on Selection Operating pressure (MPa) 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 10 100 1000 0.05 0.1 0.2 0.4 0.5 1 2 3 0.05 0.5 0.01 In order for the shock absorbers to operate accurately for long hours, it is necessary to select a model that is well-suited to your operating conditions.
Body Ported Series SX3000/5000/7000 Specifications SX3000 SX5000 SX7000 Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 Max. 50 Series Fluid 2 position single 2 position double 3 position Internal pilot Operating pressure range (MPa) Ambient and fluid temperature (C) Max. operating frequency (Hz) Manual override Pilot exhaust method Lubrication Mounting orientation Impact/Vibration resistance (m/s2
Body Ported Series SX3000/5000/7000 Specifications SX3000 SX5000 SX7000 Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 Max. 50 Series Fluid 2 position single 2 position double 3 position Internal pilot Operating pressure range (MPa) Ambient and fluid temperature (C) Max. operating frequency (Hz) Manual override Pilot exhaust method Lubrication Mounting orientation Impact/Vibration resistance (m/s2
Impact resistance of this solenoid valve is 150 m/s2. Vibration resistance of this solenoid valve is 30 m/s2. 3. Do not use in locations where radiated heat will be received from nearby heat sources.
/decel. time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S)} 8 (mm) 1000 3000 (mm/s2) = 133 (ms) -26- 5.3.4 Move distance Configuration and Operation < Move distance Configuration> Set the
Note AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 1.5 m 3 m 5 m Conductor resistance /km, 20C 65 or less Cable 25 cores x 24AWG Withstand pressure V, 1 min, AC 1000 For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius for D-sub connector cables is 20 mm.