1 MRR or 1 5 9 8 6 P5G 4 MRR 2 BAT 1 3 7 9 5 3 7 P5 BAT P5 MR BAT MR LE-CSE-SB View seen from wiring side.

131545 JIS B 2401 P5 131647 JIS B 2401 P5 131647 JIS B 2401 P5 JIS B 2401 G50 JIS B 2401 P6 JIS B 2401 G55 131336 JIS B 2401 P14 1.5-34 AR1000 to 6060 Dimensions AR1000 to 5060 Panel mounting hole AR1000 to 3060: Max. 3.5t AR4060/5060: Max. 5t AR6060 Model Port size A B C D M N P E F G H J K L Bracket mounting dimensions 25 40 53 53 70 75 90 95 11 15 25 35 37.5 40.5 48 48 M5 X 0.8 61.5 93

Spring Chamber 1 1 Chromate treatment Zinc chromate treatment Diaphragm shell Valve guide 1 1 Chromate treatment Chromate treatment Washer Valve 1 1 Rubber lining material: HNBR Spring holder Diaphragm shell 1 1 Zinc chromate treatment Zinc chromate treatment Seal O-ring holder 1 1 Chromate treatment Valve spring Name plate 1 1 Complete product No. indicated O-ring Valve seat 1 2 JIS B2401 P5

Spring Chamber 1 1 Chromate treatment Zinc chromate treatment Diaphragm shell Valve guide 1 1 Chromate treatment Chromate treatment Washer Valve 1 1 Rubber lining material: HNBR Spring holder Diaphragm shell 1 1 Zinc chromate treatment Zinc chromate treatment Seal O-ring holder 1 1 Chromate treatment Valve spring Name plate 1 1 Complete product No. indicated O-ring Valve seat 1 2 JIS B2401 P5

P5 P14-21 Drain or air continues blowing out from the drain discharge of the float type auto drain. 2. The product is not mounted correctly. Install the drain exhaust so that it will face vertically downward. P6 3. Foreign matter is caught in the main valve of the auto drain. Eliminate the dirt by manual discharge. P24-25 4. Main valve of the auto drain is broken.

P5 P14-21 Drain or air continues blowing out from the drain discharge of the float type auto drain. 2. The product is not mounted correctly. Install the drain exhaust so that it will face vertically downward. P6 3. Foreign matter is caught in the main valve of the auto drain. Eliminate the dirt by manual discharge. P24-25 4. Main valve of the auto drain is broken.

thread ridge shape is compatible with the G thread standard (JIS B0202), but other shapes are not conforming to ISO16030 and ISO1179. 1 output, without analog output, Diaphragm (18 rotation setting), Solid state(10 to 26 VDC) (ZSM1) 1 output, without analog output, Diaphragm (18 rotation setting), Reed (AC/DC 100 VAC)(ZSM1) Supply valve/Release valve combination Manual override J K A B P3 P5

In cases with a DC power supply where importance is placed on responsiveness, stay within p5% of the rated value. The voltage drop is the value in the lead wire section connecting the coil. 4. When a surge from the solenoid affects the electrical circuitry, install a surge voltage suppressor etc. in parallel with the solenoid.

1 MRR or 1 5 9 8 6 P5G 4 MRR 2 BAT 1 3 7 9 5 3 7 P5 BAT P5 MR BAT MR LE-CSE-SB View seen from wiring side.

L 1 End plate ass'y NARM2500 NARM3000 12 O-ring 1 13636A 13646A 13636B 13646B Bracket A 131515A 1349161A 3 Diaphragm ass'y NBR 2 (Except for O-ring) (Except for O-ring) Bracket 2 1 set 2 Bracket B Hexagon socket head cap screw 13649A 13639A 4 13 Valve ass'y Brass/NBR 136410 136310 5 Valve spring Stainless steel 11.5 X 8.5 X 1.5 14.5 X 10.5 X 2 6 14 Valve O-ring NBR 1 O-ring Bracket A P3 P5

63.5 91.4 87.4 104.9 93.9 AC30D-B 28 30 27.8 40.9 37.5 66.9 37.5 67.9 123.6 122 118 156.8 122.1 137.6 142.1 AC40D-B 28 38.4 27.8 48.8 42.5 75.7 42.5 75.7 155.6 154 150 186.9 154.1 169.6 174.1 AC40D-06-B 28 38.4 27.8 48.8 42.5 75.7 42.5 75.7 157.6 156 152 188.9 156.1 171.6 176.1 Note) The dimension of C is the length when the filter regulator knob is unlocked. 27 Revision history P5

AS568-025V AS568-030V AS568-035V AS568-039V AS568-043V AS568-045V Special AS568-025 AS568-030 AS568-035 AS568-039 AS568-043 AS568-045 Valve seal 1 w Standard B2401-V15V B2401-V24V B2401-P42V AS568-227V AS568-233V B2401-V85V Special B2401-V15 B2401-V24 B2401-P42 AS568-227 AS568-233 B2401-V85 Valve seal 2 e Standard B2401-P4V B2401-P5V B2401-P6V B2401-P8V B2401-P10V Special B2401-P4 B2401-P5

2 14.5 x 10.5 x 2 11.5 x 8.5 x 1.5 Valve O-ring NBR y 2 2 Bracket A Bracket B Hex. socket head cap screw Bracket assembly 1 set 2 136312 136412 JIS B 2401 P5 JIS B 2401 P3 O-ring NBR u !3 35 x 31 x 2 28 x 25 x 1.5 O-ring NBR i How to order (1) When adding n stations to ARM Regulator n pcs.

2 14.5 x 10.5 x 2 11.5 x 8.5 x 1.5 Valve O-ring NBR y 2 2 Bracket A Bracket B Hex. socket head cap screw Bracket assembly 1 set 2 136312 136412 JIS B 2401 P5 JIS B 2401 P3 O-ring NBR u !3 35 x 31 x 2 28 x 25 x 1.5 O-ring NBR i How to order (1) When adding n stations to ARM Regulator n pcs.

+ Pa) 114.5 T1 $P : Pressure drop between the static pressure tapping ports [bar] P1 : Pressure of the upstream tapping port [bar gauge] P2 : Pressure of the downstream tapping port [bar gauge]: P2 = P1 $P Q : Flow rate [dm3/s standard condition] Pa : Atmospheric pressure [bar absolute] T1 : Upstream absolute temperature [K] Test conditions are P1 + Pa = 6.5 p0.2 bar absolute, T1 = 297 p5

5 9 BAT 1 3 7 9 5 9 SHD 7 5 MR 3 P5 1 3 MR 7 P5 MR BAT 8 6 LG 4 MRR 2 BAT LE-CSE-SB View seen from wiring side.

LECSS2-T79 CN3 CN5 (USB ) 11.3 1 11 2 12 CN8 LG LG STO DI1 DI2 13 3 13 4 14 MBR DOCOM MO1 MO2 5 15 6 16 ALM DICOM LA LAR CN1A SSCNET 7 17 CN2 8 18 LB LBR 2 6 1 0 LZ LZR CN1B THM2 LG 8 4 9 19 SSCNET MRR MXR 10 20 1 5 9 DI3 INP THM1 P5 3 7 BAT EM2 DICOM MR MX CN4 CN2 CN3 PE () 11.4 3 14 3. 3.5 () (I/0)3.8.2 3.5.1 I/O EM2() EM2() EM2[Pr. PA04]2 1 _ _ [Pr. PA04] [Pr.

CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly