MDHR3-15 MDHR3-10 H L H When auto switch D-M9V is used When auto switch D-M9 is used When auto switch D-M9V is used Max. Protrusion of Auto Switch from Edge of Body: L, H Max. Protrusion of Auto Switch from Edge of Body: H (mm) (mm) D-M9V D-M9V D-M9N Auto switch model Auto switch model L H 1.3 The auto switch will not protrude in the case of D-F9. H 2.3 12-5-26
Tgpe 40 Manifold,/ Side Ported inch (mm) Grommet (G), (H) Lead wire length L typ plug connector (L) M type plug connctor (M) Type 40R Manifold,/ Side Ported(External Pilot) inch (mm) Grommet (G), (H) L type plug connector (L) M type plug connector (M) inch (mm) crommet (G), (H) 4O Manifold,/ Bottom Ported (ln case oa to-32No.n.
(mm) Thread Weight g Applicable tubing A B C D E F H Model 3 2 1 M3 x 0.5 M5 x 0.8 M-3AU-2 M-5AU-2 4.5 7 9 10 3 4 5 7.7 0.9 0.7 1.5 4 2 x 1 .2 4 Thread Component Parts E D Material Brass Brass No. 1 2 3 Description Sleeve Barb fitting Gasket Note Electroless nickel plated Electroless nickel plated F K NBR, Stainless steel M B C A H Width across flats H Barb elbow: M-3ALU-2, M-5ALHU-2 D Applicable
Note 2) Non-locking push type (tool required) Locking type (tool required) Nil B Note) Note 2) Manifold block specification H Note 2) Note) Except double (latching) type. Nil M MB Note 1) For the double solenoid specification, the symbol for Function is "D". Note 2) Only rubber seal types are applicable.
effective area Q=11S P(P2+1.033).kg/h Equation in the domain of sonic flow Calculation by Cv factor Q=98.9Cv(p1+1.033).kg/h Calculation by effective area Q=5.51S(P1+1.033).kg/h 4.2-38 VND Flow Characteristics Water/VND 2 to 7 should be N.O. to suppress water hammer.
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): -, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): null~0.7, Power Supply: DC24V, Accessories/options: ordered separately: Power supply cable included (10 m) / with bracket, I/O specifications: PNP output, Bar length
Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: NPN Output, Power Supply Cable, AC Adapter: H (e-con Connector, Power Supply Cable to be Provided & Prepared by Customer)
Cooling Capacity: 30 kW, Type: -, Pump Inverter Control: -, Option: -
Cooling Capacity: 8 kW, Type: -, Pump Inverter Control: -, Option: -
Cooling Capacity: 15 kW, Type: -, Pump Inverter Control: -, Option: -
Cooling Capacity: 1kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 2kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 4kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 8kW, Temperature Set Range: 20°C to 90°C, Option: -
method: Sealant For R, NPT thread Indicator window direction: 0 Indicator window direction: 180 D3 W1 W2 X Y Applicable tubing O.D. d A L4 D1 L3 M L2 L1 T H (Width across flats) Metric Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FS-01-23 (S) 3.2 7.2 13 (13) AS221FS-01-04 (S) 4 8.2 AS221FS-01-06 (S) 6 10.4 14