SMC Corporation of America
Elite Part Number Search
Search Results "ISE70G-02-L2-ML"

Pressure Range: 0 to 1 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: Y (None)

Type 31 How to Order Applicable solenoid valve Note) SY113--M3 SY113A--M3 SY123--M3 SY123A--M3 Applicable blanking plate assembly SY100-77-1A SS3Y1 31 05 Stations 02 2 stations P R 20 20 stations R port M5 x 0.8 P port M5 x 0.8 Note) SY113(A) and SY123(A) cannot be mounted on the same manifold.

= 26 x n + 12 2 76 64 3 102 90 4 128 116 5 154 142 6 180 168 7 206 194 8 232 220 9 258 246 10 284 272 L L1 L2 [ ]: With light/surge voltage suppressor 4-7-8

NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.

List part numbers of the installed valve and option in required station location separately under manifold part number. 2.1-10 Series SY100 Common SUP/Common EXH 30 Type How to Order Applicable solenoid valve (1) SS3Y1 30 05 F SY113-l-M3 SY113A-l-M3 Stations 02 Applicable blank plate assembly 2 stations ... ...

(max. 20 stations) Valve stations Supply/Exhaust block assembly fitting specifications Note Symbol 02 Stations 2 stations Double wiring specification Straight Nil L B Supply/Exhaust block assembly mounting position 08 02 Elbow fitting (upward) 8 stations Elbow fitting (downward) 2 stations Specified wiring (up to 16 solenoids are possible) U D B M U Side (2 to 10 stations) D Side (2 to

R Right side (PV port on the right side) L Left side (PV port on the left side) 02 2 B Both sides (PV port on both sides) Nil All stations 1 Station 1 only 08 8 1 Viewed from the front side of valve unit, confirm the port location on the right and/or left side. 2 EXH ports are released to atmospheric pressure in both sides.

VE 3 Bleed port Model (Made to Order) Pressure range Note) Indication unit Connection thread VY1 Note Model MPa G43-2-01 to 02-X2 G43-4-01 to 02-X2 G43-6-01-X2 G43-7-01 to 02-X2 G43-10-01 to 02-X2 G43-2-01 to 02-X3 G43-4-01 to 02-X3 G43-6-01-X3 G43-7-01 to 02-X3 G43-10-01 to 02-X3 G43-2-01 to 02-X4 G43-4-01 to 02-X4 G43-6-01-X4 G43-7-01 to 02-X4 G43-10-01 to 02-X4 0 to 0.2 0 to 0.4 0 to 0.6

Dimensions Front mounting flange 20 to 50 Width across flats MA MM MD (MI) R ML MT Stroke MH + Stroke Y + Stroke ZZ + 2 strokes Front mounting flange 63 Width across flats MA MM MD (MI) R Stroke ML MT MH + Stroke Y + Stroke ZZ + 2 strokes (mm) MT Adjustment 0 to 25mm Adjustment 0 to 50mm Bore size (mm) R Y MA MD MI MM MH 63 66 66 72 85 85 ML 43 43 43 47 53 53 ZZ 179 189 191 215 254 256 MH

The ISE70G pressure sensors provide continuous quantitative values, as well as switched digital outputs when pressure set points are met.  Compatible fluids include any non-corrosive liquid or gas.  6 pressure ranges are offered up to 50 MPa.  This sensor is also IO-Link compatible.