Hs T (mm) Symbol BX BY D F GA GB L M N S T W Wc Ws Z ZZ Hs IA K Bore size 40 56 54 16 44 77 10 55 M12 x 1.5 86 112.5 57 5 39 27.5 114 228 46 47 14 50 64 64 20 55 78.5 10 58 M16 x 1.5 87.5 117 60 7 41 33 118.5 232.5 50 58 17 63 74 74 20 69 82 12 58 M16 x 1.5 91 120.5 67 5.5 48 39 122 236 56 72 17 12 Series CLK1 Clamp Cylinder with Lock Accessory Dimensions (mm) Single Knuckle Joint Double

Do not expose the actuator motor to a magnetic field with a magnetic flux density of 1 mT or more. (1) When installing an air cylinder with an auto switch (ex. CDQ2 series) by side, maintain 40 mm minimum space around the motor.

Please contact SMC for a specification sheet when placing an order. Shaft Pattern Sequencing II -XA31 to XA47 Applicable shaft type: J, K, S, T, Y Shaft type CRB2 J K Refer to CRBU2 S page 11-2-8.

Please contact SMC for a specification sheet when placing an order. Shaft Pattern Sequencing II -XA31 to XA47 Applicable shaft type: J, K, S, T, Y Shaft type CRB2 J K Refer to CRBU2 S page 11-2-8.

Please contact SMC for a specification sheet when placing an order. Shaft Pattern Sequencing II -XA31 to XA47 Applicable shaft type: J, K, S, T, Y Shaft type CRB2 J K Refer to CRBU2 S page 11-2-8.

The piston speed may exceed the maximum operating speed of 500mm/s if the piping is directly connected to the cylinder. Please use speed controllers by SMC to adjust the piston speed so that it will not exceed 500mm/s.

In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.

Direct operation valve Qmax 11.1 Effective area S = (mm 2) Qmax 11.1 Effective area S = (mm 2) Select a valve (solenoid valve) having an effective area that is greater than that of the effective area formula given above from the related equipment (P . 13-14-4).

After 1.6 s Blinking After 0.2 s When an alarm or warning also occurs during the test operation, the decimal point on the first digit will blink as follows. After 0.8 s After 0.8 s Blinking Blinking After 0.2 s (4) Start operation with the PC. -21- 5.2 JOG Mode JOG operation can be executed without host command.

Bore size (mm) 40 10 Auto switch model 50 63 80 100 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F/F5NTL BT-04 BT-04 BT-06 BT-08 BT-08 1 100 D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G59F D-G5NTL 1000 500 BDS-04M BDS-05M BMBI-063 BMBI-080 BMBI-100 Maximum speed (mm/s) (Example) Find the upper limit of rod end load when an air cylinder of 63 is operated at 500 mm/s.

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

The only possible way in that case is the use of an external stopper.

Order Made Note) When an auto switch is installed at an intermediate position of a type with auto switch, keep the maximum piston speed at 300 mm/s or below to ensure operation of relays or other devices.

There may be the case it will vary substantially depending on an ambient environment.

It may vary substantially depending on an ambient environment.

Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.

Operation stop Combination Symbol: D1 Combination Symbol: D4 An N.C. solenoid valve is used for the vacuum release valve. An external supply valve must be provided. An external valve must be provided to serve as the supply valve. An air operated N.C. valve is used for the vacuum release valve.

Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.

Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.