Depending on the external switch output type, wire the switch to the connector for contact input / output (which is included as an accessory) as shown below. Mount the ferrite core (3 turns), which is included as an accessory. This is an example of wiringRefer to the Communications Operation Manual for more details.

The Grounding point should be as near as possible to the controller. Keep the grounding cable as short as possible.

Environment at an altitude of 1000 meters or higher Heat radiation and withstand voltage will decrease. Contact SMC for details. (2) Do not use in an environment where the product is directly exposed to liquid, such as cutting oils.

Mounting is the same as standard types.

An amplifying circuit and a dividing circuit are required to produce output which can be read by the counter, and these are accommodated in the case on the cylinder. The sensor head and amplifier section together are referred to as the sensor unit.

Be sure to connect the load to the rod end with the cylinder in an unlocked condition. If this is done when in a locked condition, it may cause damage to the lock mechanism. 1. Do not perform unlocking when an external force such as a load or spring force is being applied. This is very dangerous because the cylinder will move suddenly. Take the following steps. CL CL1 2.

Use a flexible material for piping (such as a rubber hose) and an accumulator that can absorb impact pressure. 3. Keep piping as short as possible. Use the product within the specified operating pressure and temperature range. Reserve a space for maintenance.

Same as standard type Warning Operating Precautions Be aware that smoking cigarettes, etc. after your hands have come into contact with the grease used in this cylinder can create a gas that is hazardous to humans. 46 Series NCQ8 The number of surfaces and grooves where an auto switch can be mounted (as direct mounting).

Vacuum switch Series ZS 13-1-6 Model Selection Single Unit System Equipment such as an ejector is configured as an individual unit. Thus, it is possible to create a flexible system configuration in which the circuit composition and the mounting locations can be selected as desired.

Trouble shooting 9.1 Alarm and Warning POINT Turn the servo-ON (SON) OFF and shut off the main circuit power supply as soon as the alarm occurs. An alarm or warning is displayed when an abnormality occurs during operation. When an alarm or warning occurs, take appropriate measures according to "LECSN-T Operation Manual, Chapter 8. When an alarm occurs, the ALM is turned off.

The current target position data is sent D9004 Target position 4 as an encoder count value. Step Data number being executed is D9006 Step Data number executed 2 sent. (a) Positioning data (encoder count value) The current position data is sent as an encoder count value. Count value 1,000,000 has been fixed for 0 mm as a reference point.

Manual Override Caution Light/Surge Voltage Suppressor Caution Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Push type is standard. Locking type (Tool required) is available as an option. 1.

Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 6. Do not use in an environment where there is excessive impact shock.

Color may not be available as shown.

The valves are assembled as N.C. valves at the time of shipment. By removing the two retaining screws from the desired valves, and rotating each valve body 180 and reassembling it on the manifold base, it is possible to reassemble an N.C. valve as an N.O. valve. (When doing so, make sure that a gasket is attached to the mounting surface of the valve.) Properly tighten the screws.

DeviceNet compatible SI unit As a DeviceNet slave unit, it is capable of solenoid valve ON/OFF control up to a maximum of 32 points. In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.

V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 30 m. When using it as an IO-Link device, do not use a cable longer than 20 m. Wire the DC (-) line (blue) as close as possible to the power supply.