Therefore, if an external stopper is used to stop the piston rod and the lock is engaged, the piston rod will shift in the amount of its axial play. 6. To effect an intermediate stop, take the cylinders stopping precision and overrun amount into consideration.
Caution When using an exhaust cleaner, mount it downwards.
Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting bracket contact the cylinder tube firmly. (Use a hexagon wrench.) 2. Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. 3.
There may be the case it will vary substantially depending on an ambient environment. 325 CHM Series Auto Switch Mounting Brackets: Part Nos.
Base mounted (with sub-plate) 65 (51) 1/8 61 (47) 60 (46) 82 (68) V100 Note) Value for DC. Add 1 g for AC. ( ): Without sub-plate.
Not installable Food zone An environment where food which will be sold as merchandize, directly touches the fitting components. Installable Splash zone An environment where food which will not be sold as merchandize, directly touches the fitting components. An environment where there is no contact with food.
Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.
VHS50 1/2 Note) Use an air filter on the IN side for operating protection. F 28 30 36 44 54 E 33 42 44 50 61 D 45 55 58 65 76 C 20 29 39 42 53 B 59 78 107 110 134 AA 34 46 63 67 78 A 40 53 70 75 90 H 45 55 63 69 81 G 22 21 26 Model VHS20 VHS30 VHS40 VHS40-06 VHS50 Caution on Mounting 1.
If there is no buffer mechanism, an excessive impact force is generated. As a result, the tensile compression force of the floating joint may exceed its maximum level.
Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. Sizes 20 through 32 have a built-in holding function for the unlocked state, allowing the unlocked condition to be maintained even without an air supply.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
Do not install in Zone 0 (as defined in IEC 60079-101:2008) or Zone 20 (as defined in IEC 60079-10-2:2009) Zone 0 area classification: An area in which an explosive gas atmosphere is present continuously or for long periods or frequently.
Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. Sizes 20 through 32 have a built-in holding function for the unlocked state, allowing the unlocked condition to be maintained even without an air supply.
Install an air filter Install an air filter of 5 m or smaller filtration on upstream side. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.
41.5 48 56 80 83 86.5 D-F7lWV 5 14 18 40 45 42.5 39.5 46 54 78 81 40.5 D-A9ll 3 12 16 38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16
Select an air-hydro type in combination with an air-hydro unit. Since good operation of an air-hydro type depends on its combination with an air-hydro unit, carefully select an appropriate air-hydro unit. Maintenance Caution 1. Bleed air from the air-hydro type on a regular basis. Since air may accumulate inside the air-hydro type, bleed air from it, for example before starting work.
Use an exclusive crimping tool for crimping. (Please contact SMC for the dedicated crimping tools.)
[Tips]
Do not use the cylinder under following environments: 1) An area in which fluids such as cutting oil splash on the piston rod. 2) An area in which foreign matter such as particles, cutting chips, dust, or spatter is present. 3) An area in which the ambient temperature exceeds the operating range. 4) An area exposed to direct sunlight. 5) An environment that poses the risk of corrosion. 1.
Note 5) The system accuracy when combined with an applicable flow sensor.